| 1 | BLDG WRK |
| 2 | Taking down cement plaster of any description, thickness on brick, stone, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, removal of rubbish and cleaning, etc complete as directed and specified. |
| 3 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete as directed and specified. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed . |
| 5 | Demolition of cement concrete (un reinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 6 | Demolition of brick work in cement mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 7 | Dismantling timber scantling 40 sq cm and over in section , in any position for unframed work complete all as specified and directed by Engr-in-Charge |
| 8 | Dismantling Mild Steel work of any description as in steel gate, post purlin, etc not otherwise provided for complete all as specified and directed by Engr-in-Charge |
| 9 | Dismantling of steel/galvalume sheets of any description (corrugated, semi corrugated, etc.)sheets in roof coverings complete all as specified and directed by Engr-in-Charge |
| 10 | Dismantling wall and ceiling board, of any description complete all as specified and directed by Engineer in Charge |
| 11 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.50 sqm and n exc 4.00 sqm each complete all as specified and directed. |
| 12 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each complete all as specified and directed. |
| 13 | Dismantling of cast iron/ PVC /AC /SGSW pipes alongwith fittings and accessories upto 100 mm dia jointed in cement mortar and taking out of walls, floors or trenches, if required complete all as specified and directed. |
| 14 | M& L for 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed. |
| 15 | M & L for 25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in floors, to receive surface of tile complete all as specified and directed. |
| 16 | M&L for vitrified ceramic dark/light shade/double charged/Ultra charged coloured tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 17 | M&L for vitrified ceramic dark/light shade/double charged/Ultra charged coloured tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm sqm, on vertical surface etc. and including 10 mm thick plaster in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 18 | M&L for vitrified ceramic light/dark shade/Full body porceline coloured tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but n exc 0.42 sqm, in floors etc.with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 19 | M&L for vitrified ceramic light/dark shade/Full body porceline cloured tiles tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but n exc 0.42 sqm , on vertical surface etc. and including 10 mm thick plaster in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 20 | M & L 16 to 18 mm thick granite(Zed Black colour as approved by GE) stone slab machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform/dado/skirting /plateform counter top WHB in cluding cutting holes for oval shape WHB /urinal partitions etc. in horizontal or vertical surfaces including grinding the edges half round and polishing with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6) set complete all as specified and directed by Engineer-In- Charge. |
| 21 | M&L for vitrified full body exterior coloured tiles 12 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm , in floors/skirting /riser/dado/treads etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 22 | M&L for brick work with old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed. |
| 23 | M&L for 15mm thick rendering in cement mortar 1:6 to on brick masonary wall surfaces or on other than fair faces of brick masonary finished even and fair without using extra cement complete all as specified and directed. |
| 24 | M & L for 15 mm thick rendering in two layers on fair faces of brick work or concrete surfaces first layers 10 mm thick with cement mortar 1:6 on fair faces of brick work or concrete surfaces and second layers 5 mm thick with cement mortar 1:4 with mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed.Note:- Water Proofing compound shall be measured and paid seperately. |
| 25 | M&L for rendering 5 mm thick in CM 1:3 as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed. |
| 26 | Taking down existing un-serviceable water proofing treatment from roof slab and cleaning the roof slab by wire brush and removing WPT felt exc 500 mtr but not exc 1.50 Km etc complete all as specified and as directed |
| 27 | M & L for applying cement slurry over existing roof surface @ 3 Kg/Sqm incl mix with water proofing liquid @ 0.15 ltr per 50 kg cement bags as per manufactures instructions complete all as specified and directed. |
| 28 | M&L for cement concrete 1:2:4 type, B0 using 12.50 mm graded stone aggregates as in copings, roof padding/staging of water tank etc including fair finish with using extra cement including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed .Notes :- Rates includes to carried out the work on roof slab up to 3rd stories building nothing extra shall be admissible on this account |
| 29 | M&L for 3 mm thick APP modified prefabricated in five layers & weight not less than 3.6 Kg/Sq mtr water proof membrane reinforced with non-wooven polyster with two coat of water proofing aluminium paint over top surface of water proofing membrane with 15 cm longitudinal & horizontal over lapping and joints finally pasted with thermo- fused with LPG flames laid over a coat bitumen @ 1.20 Kg /Sqm over a coat bituminous of primer 0.40 ltr per sqm over after cleaning existing plastered surfaces as per manufacturer instruction of APP modified membrane etc. APP modified membrane shall be laid on bitumen surface by torch application method after allowing 24 hours to dry, complete all as specified and as directed.Notes :- Rates includes to carried out the work on roof slab, nothing extra shall be admissible on this account |
| 30 | S & F 1st class hard wood (Teak) Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, Famed and manufactred in situ. Note :- The contractor shall bring the trunk of appropriate size as per direction of Engineer in charge at site and necessary cutting and manufacturing shall only be done at site. No factory made material shall be allowed. |
| 31 | S & F 35 mm thick 1st class hardwood (Teak) manufactured in situ Glazed and skeleton shutters( single/ double), open rebated and prepared to receive glass, gauze, etc divided into squares, with plain,chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a). Note :- The contractor shall bring the trunk of appropriate size as per direction of Engineer in charge at site and necessary cutting and manufacturing shall only be done at site. No factory made material shall be allowed. |
| 32 | S & F 35 mm thick 1st class hardwood (Teak) manufactured in situ Plain, framed, panelled shutters (single/ double) (any number of panels), with panels of timber flat on both sides (feather edged). Note :- The contractor shall bring the trunk of appropriate size as per direction of Engineer in charge at site and necessary cutting and manufacturing shall be only done at site. No factory made material shall be allowed. |
| 33 | S & F 30 mm thick 1st class hardwood (Teak) manufactured in situ Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc divided into squares, with plain,chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b). Note :- The contractor shall bring the trunk of appropriate size as per direction of Engineer in charge at site and necessary cutting and manufacturing shall only be done at site. No factory made material shall be allowed. |
| 34 | S & F factory made WPC single extruded 100 % lead free ROHS certified board of 18 mm thick pre laminated moulded sides & partition of Cupboard, shutter for cup board/kitchen cupboard. The laminated shutter should be 10 mm deep mould on the pre laminated side with different design and other side plain white of density not less than 600 kg/cum manufactured by an ISO 9001:2015 certified company. The 18 mm board should be 100 % lead free, water proof, termite proof and borer proof and should have good screw holding capacity and complete all as specified and directed including dismantling & removl of existing unserviceable cup boards.Make:- Kumar Arch Tech Pvt.Ltd/Rajshree/Fiber Techno Products/EcoCell/TVL Engineering Pvt Ltd (Florista)/Black cobra (Yamuna interiors Pvt Ltd) |
| 35 | S&F ball catches with 8 mm dia steel ball magnet catches for cupboard shutter including striking plate as approved etc complete all as specified and as directed |
| 36 | S&F in repairs stainless steel decorative curtain rod of 25 mm bore including brackets 02 nos, finale 02 nos etc complete all as specified and as directed |
| 37 | S & F for stainless steel glossy finish hat peg set of five tier with necessary fitting complete all as specified and directed. |
| 38 | S&F Looking mirror 5.50mm thick area 1.00 Sqm to 1.50 Sqm bevelled edge of selected quality glass mounted on 6mm thick commercial plywood and fixed with min 4 Nos SS studs complete all as directed. |
| 39 | S&F for 100 mm bore Cast iron spun pipe (for Rain water) in any length without ears with cement joint fixed to walls complete all as specified and as directed |
| 40 | S&F 100 mm bore cast iron Bends of (any radius), spun pipe diminishing piecs or tapers (larger bore measured) complete all as specified and as directed |
| 41 | M & L for ATT post construction Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified. |
| 42 | M & L for ATT post construction Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified |
| 43 | S&F MS joist channel, angle or Tee section MS tubes, flats square bars etc fixed indepently or framed or without connecting plates ,trusses etc any type framing including purlins and rafters etc confirming to Fe 410-W Gde E-250 Quality A complete all as specified and directed by Engr-in-Charge |
| 44 | S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge |
| 45 | S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick for ridge cover of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge |
| 46 | M & L minimum 24mm x 160mm x 2900mm size WPC Lining fluted panels (fixed to wall/Ceiling) inclusive of solvent and ceiling system with GI frame work comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including hanger bars to support the ceiling to roof complete all as per manufacturer's instruction including dismantling existing ceiling/panelling complete all as specified and directed by Engineer in charge |
| 47 | M&L for Preparation of old steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with one coat of synthetic enamel paint complete all as specified and as directed |
| 48 | M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed |
| 49 | M&L three coats of white wash on ceiling on new plastered surfaces including preparation of surfaces complete all as specified and as directed |
| 50 | M&L one coat of white wash on ceiling on Old decorated surfaces including preparation of surfaces complete all as specified and as directed |
| 51 | Complete removing of existing treatment from wall / ceilling complete all as specified and directed. (Note : The rate of scafolding is included for this item also) |
| 52 | M&L for preparation of new wall surface/ surface and applying wall care putty 2.0 mm thick (Asian /Berger/JK) to make the surface smooth as specified and directed by Engr-in-Charge. (Note : The rate of scafolding is included for this item. After completion of preparation of surface as per item above the stage has to be passed by Engr-in-charge complete all as specified and directed) |
| 53 | M&L for preparation of new plastered/unplastered/puttied wall surfaces of any description and applying two coat of acrylic distemper white or any tint over a coat of alkali resistant primer etc over prepared wall surfaces complete all as specified and directed. (Note : The rate of scafolding is included for this item. Applying coat after completion of preparation of surface as per item above and stage has to be passed by Engr-in-charge before complete all as specified and directed) |
| 54 | M&L for preparation of new plastered/unplastered/puttied wall surfaces of any description and applying two coats of weather proof exterior emulsion paint over a coat of primer complete all as specified in SSR Part I and directed by Engr-in-Charge .(Note : The rate of scafolding is included for this item also. Applying coat after completion of preparation of surface as per item above and stage has to be passed by Engr-in-charge before complete all as specified and directed) |
| 55 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for complete all as specified and as directed |
| 56 | M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) (nominal mix) as in slabs supported on wall, landing, balconies, canopies, deck slabs and in shelves and like Chajjas, Claddings, soffits etc including bonding agent, complete all as specified and directed. Note:- Reinforcement shall be measured & paid under respective items. |
| 57 | M&L for form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat, complete all as specified and directed. |
| 58 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and as directed |
| 59 | M & L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide, finished rough finished surface complete all as specifed and directed |
| 60 | M&L for TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 61 | Supply only liquid water proofing compound complete all as specified and directed. |
| 62 | S & F 6 mm thick waterproof, termite proof and fire resistant HPL Board planks of suitable size for external facia and façade complete all as specified and directed |
| 63 | S & F hydraulic concealed hinge with clip on installation and integrated Silent System, opening angle not less than 100º, For shutter thickness 15 - 24 mm full overlay type shutters, hinge cup dia 35 mm including necessary fixing arrangement with SS screw complete all as specified & directed. |
| 64 | S & F 1.60 mm thick plain black skeet in wall cladding, steel gates , framed work, ornamental work etc and similar work cut to size, holes punched including round headed screws clout nails or riveted and fixed to wood or steel framing with plain 40 mm lap joints with rivetted or welded seams, including bending or turning up, mitered angles, etc as required complete all as specified and directed |
| 65 | S & F 125 mm size butt hinges extruded brass with mild steel hinge pin bright polished anf fixed complete all as specified |
| 66 | S & F 75 mm size butt hinges extruded brass with mild steel hinge pin bright polished anf fixed complete all as specified |
| 67 | S&F 150 mm long Extruded brass handle(fancy polished),etc complete all as specified and as directed |
| 68 | S&F 100 mm long Extruded brass handle(fancy polished) etc complete all as specified and as directed |
| 69 | S&F 200 mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed |
| 70 | S&F 125 mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed |
| 71 | S & F 300 mm long and 12 mm dia (min) Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed compete all as specified. |
| 72 | S & F 200 mm long and 10 mm dia (min) Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed compete all as specified. |
| 73 | S & F 300mm,Brass ordinary rat tail rod pattern springs including roller and roller plate complete |
| 74 | S & F 1st class hardwood (Teak) manufactured in situ Moulding as in cornices, picture rails and the like n exc 6 Sqcm in sec as directed by Engineer in Charge .Note :- The contractor shall bring the trunk of appropriate size as per direction of Engineer in charge at site and necessary cutting and manufacturing shall only be done at site. No factory made material shall be allowed. |
| 75 | M & L for melamine polishing on surfaces of any description, width or girth including cleaning, preparing the surface with sand paper including base coat, coat of melamine wood filler on new works with two or more coats, and finishng with top coat of melamine with two or more coats complete all as specified and as directed by Engineer in charge |
| 76 | S&F sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc. 0.5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed. |
| 77 | S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed. |
| 78 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed |
| 79 | S&F for mild steel work as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings and similar work including welding,conforming to FE-290 grade E-165 complete all as specified and directed. |
| 80 | PCC 1: 3 : 6 type C1 using 20 mm graded aggregates in surface channels and drains including necessary use & waste of formwork and demolition of existing old cement concrete of any description complete all as specified and directed. |
| 81 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi tred/stopped ends etc complete all as specified and directed. |
| 82 | M & L for 75 mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection or similar places and finishing the surface even & smooth with out using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meter and every change of direction and filling the same with mixture of bitumen & sand in ratio (1:1) by weight including necessary form work etc and including demolition of existing old cement concrete, complete all as specified and directed. |
| 83 | Supply and spreading 75mm thick layer of Shingle/gravel on walking track of cadet near building. |
| 84 | S&F Non skid ceramic Coloured floor tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.36 sqm in floors etc with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement complete all as specified and directed. |
| 85 | M&L for coloured Glazed ceramic tiles in vertical surface such as dado etc 450mmX 300mmX 7 to 8mm/300x600x7 to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:6 complete all as specified and as directed. |
| 86 | Taking up or down 15mm bore, steel tubing and connection including removal from site complete all as specified and directed. |
| 87 | Taking up or down 20mm bore, steel tubing and connection including removal from site complete all as specified and directed. |
| 88 | S&F of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with all fittings complete all as specified and directed |
| 89 | S&F of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with all fittings complete all as specified and directed |
| 90 | Cutting chases in brick/stone walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed |
| 91 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other frames/ Chowkhat of Size 45x70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder)/ rice husk/ Wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having miniumum frame density of 750 Kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compresssive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistancce to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS Hold fast/ lugs/ SS dash fasteners of required dia and length complete all as per specified and directed by Engineer-in-Charge. |
| 92 | S & F factory made Single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (suspension Grade), Calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/cum and screws withdrawal strenght of 1800 N (face) & 900 n (Edge), minimum compressive strenght 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S Screws, complete all as specified and directed by Engineer in Charge. |
| 93 | S & F in repair 15mm bore 2 in 1 wall mixer fancy type, cast copper alloy with chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and as directed |
| 94 | S & F in repair 15mm bore WHB mixer fancy type, cast copper alloy, with long swan neck, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and as directed |
| 95 | S&F in repair 15mm bore bib tap long body fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down for iron pipe or brass ferrule or fixed for 15mm dia bore pipe complete all as specified and directed. |
| 96 | S&F in repair 15mm bore bib tap short body fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down for iron pipe or brass ferrule or fixed for 15mm dia bore pipe complete all as specified and directed. |
| 97 | S&F in repairs angle valves/stop cock fancy type chromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for Unions and fixed for 15mm dia bore pipe complete all as specified and directed. |
| 98 | S&F in repair Tubular towel rail, ISI marked 60cm long between flanges , 20mm dia 'D' type Brass Chromium plated incl brackets, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 99 | S & F in repair fancy type brass chromium plated Soap dish of size 160x 160x90mm complete all as specified and directed |
| 100 | S & F in repair vitreous china wash hand basin counter sunk type including brackets, white size (550 x 400mm) incl cutting for and pinning inends of brackets 32mm dia chromium plated waste fitting and PVC waste pipe 610mm long with MS brackets complete all as specified and as directed. |
| 101 | S&F in repair Vitreous China wash down water closet pan padestral pattern with spun pipe 'P' or 'S' trap, white including PVC seat cover and connection to drain or outgoing pipe and flush pipe, anti syphonize pipe etc fixed complete all as specified and as directed. |
| 102 | S&F in repair of PVC low level flushing cistern dual flush top push 10 Ltr capacity symphonic action type white as approved, ball valve float valve and handle, flush pipe incl CP bracket complete all as specfied and directed. |
| 103 | S & F in repairs Vitreous China Urinal half stall pattern, basin only including connections to flushing pipe, urinal spreader, waste pipe and outgoing pipes fixed (excluding flushing cistern) complete all as specfied and as directed. |
| 104 | S&F in repairs Health faucet (ABS Body/CP body) mile steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and abs/CP wall hook including makeing connection and fixed in position complete all respect and specified. |
| 105 | S&F in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 106 | S&F in repair 15mm dia 600 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes complete all as specified and directed. |
| 107 | S & F in repair for 75mm bore out let cast floor trap spun pipe ( conforming to IS 3989) including cockroach trap with gratings including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) etc complete all as specified and directed. |
| 108 | S & F for 75mm bore cast iron spun pipe ( conforming to IS 3989) soil, waste and vent pipes, in any length with or without ears with lead joints, laid in trenches or in floors or fixed to wall vertically complete all as specified and directed. |
| 109 | S & F for 75mm bore cast iron bends of (any radius),spun pipe ( conforming to IS 3989) diminishing pieces or tapers (larger bore measured) with lead joints complete all as specified and directed. |
| 110 | S & F for 75mm bore cast iron tee of (any radius),spun pipe ( conforming to IS 3989) diminishing pieces or tapers (larger bore measured) with lead joints complete all as specified and directed. |
| 111 | S & F for 75mm bore cast iron cowls spun pipe (conforming to IS 3989) complete all as specified and directed. |
| 112 | Dismantling water tanks of capacity 1000 ltrs complete all as specified and directed |
| 113 | S & F 1000 ltr Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) with Ball brass valves, high pressure, with 20 mm polythene float and flynut complete, screwed for iron pipe or brass ferrule hoisted and fixed in position incl refixing of inlet, outlet & over flow pipe all as specified in SSR Part I |
| 114 | S&F in repair Gun-metal, globe or gate valves, for 20mm bore pipe with iron wheel head, screwed both ends for iron pipe and fixed |
| 115 | S&F in repairs Brass CP shower rose 125mm size including fixing to steel pipe or union complete all as specified and directed. |
| 116 | E/M WRK Please Enable Macros to View BoQ information |
| 117 | E/M WRK Please Enable Macros to View BoQ information |