| 1 | S&F for powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portion) with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, straight, mitred and jointed mechanically whetever required including cleat angle, Aluminium snap beading for glazing/ panellig C.P brass/ stainelss steel screws, all complete as per architectural drawings and directions of Engineer-in-Charge. |
| 2 | S&F for Anodised aluminium powder coated (thickness of powder coating not less than 50 micron) door shutters aluminium section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges anodised aluminium shap beading screws etc. complete all as specified and directed. |
| 3 | S&F for Sheet glass 5.5 mm thickness, ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane as per instructions of manufactruers . |
| 4 | S&F for 12 mm thick particle board for insulation purposes, fixed with screws to aluminium frame work complete all as specified and directed. |
| 5 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars etc complete all as specified and directed. |
| 6 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM (1:6) finished even and smooth without using extra cement all as directed by Engr-in-Charge |
| 7 | M&L for preaparation of newly plastered wall surfaces and applying two coats of Oil Bound Distemper over a coat of chalk whitening (preparatory to distemper) applied over 1 to 2mm thick BIRLA/ JK (or equivalent) water-proof wall care putty complete all as specified and directed by Engineer-in-Charge. |
| 8 | S&F in repair mild steel mortice lock 4 levers, vertical type, size 100mm complete all as specified and directed. |
| 9 | S&F for anodised aluminium powder coated (thickness of powder coating not less than 50 micron) window and ventilator shutters, sliding type with sash bars, aluminium sections weighing 0.55kg/mtr including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no) hinges type B-21 100mm long (2 No) suitable handle (1 No) complete all as specified and directed. |
| 10 | S&F for mild steel in framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes; framed guard brars barred iron doors; ladders; framed baulsters ; walk ways railings; frame work of water tank and similar work conforming to Fe 290. Gde E-165 |
| 11 | S&F aluminium anodised barrel tower bolt of extruded section 150mm long and fixed all as sopecified and directed. |
| 12 | M&L for 150mm thick cement concrete type C2 (1:3:6) using 40mm graded aggregate as in floor and pavings complete all as specified and directed. |
| 13 | S&F for submain wiring with 2 single core PVC insulated and PVC unsheathed FRSLH cable 1100 volt grade with 04 Sqmm copper multistranded conductor drawn through and including PVC medium grade surface casing capping not less than 20mm width in wall. ceilings/ roofs including 4 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulatd and unsheathed FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.Note : (i) Two run of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one lengtth only. |
| 14 | S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SP C curve 20 Amps complete all as specified and directed. |
| 15 | Suppy, installation, testing and commissioning dual rotary compressor inverter technology split type air conditioners capacity 1.0 TR, 5 Star rating (6 in 1 convertible), single phase, 230 Volt, 50 Hz designed for ambient temperature upto 52 degree celcius with acoustic jacket oon compressor suction tube size outer diameter 5/8\\" liquid tybe size outer diameter 3/8\\" power supply to outdoor unit source 4 Core 2.5 Sqmm power supply to indoor unit source 3 core 2.5 Sqmm complete with cordless remote control unit LCD with back lit with night glow function on remote buttons and remote battery type including supply and fixing / grouting of best quality mounting bracket for outdoor unit complete with and inclusive of 25mm PVC pipe for drain pipe of suitable length including making fabrication of shed on wall floor for outdoor unit with the help of MS angle iron of size 25x25X3 mm and MS sheet on minimum 1mm thickness to prevent the outdoor unit from direct exposure of rain/ sun rays. Size and height of shed should be appropriate to cover the complete outdoor unit for wall mounted outdoor unit two nos angle iron will be groute in wall and MS sheet will be fixed on angle iron with nut bolts etc, for floor mounted outdoor unit 04 Nos angle iron will be groute in floor / ground with suitable type PCC and MS sheet will be fixed over it with the help of nut/ bolts etc complete alll as specified and directed. |
| 16 | S&F copper tube of size 1/2\\" or 5/8\\" (suction) and 1/3\\" or 3/8\\" dia (delivery liquid) covered with 12m thick PU form for outdoor and indoor unit connections for split AC including all fittings and fixed on walls/ ceilling through MS clamp complete all as specified and directed. |
| 17 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170volt to 260 volt with output voltage stabilized at 230 volt with accuracy of ± 2.5% and of capacity 4 KVA (for 1.0 Ton AC) Please Enable Macros to View BoQ information |