| 1 | Sch A Part I (B/R Portion)M & L Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In Hard/dense soil.completed all as specified |
| 2 | Excavating in trenches, by mechanical means(hydraulic excavator) n exc 1.5 m wide and n exc 1.5 m in depth; for footing, Plinth Beam & Dwarf Wall, etc. n exc 10 sq m on plan and getting out in Hard/dense soil. |
| 3 | M & L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface |
| 4 | M & L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) |
| 5 | M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall |
| 6 | M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area |
| 7 | M&L for hardcore of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface of a broken stone or boulders complete all as specified and directed. |
| 8 | M & L Cement concrete in foundations, filling and mass concrete 1:4:8 using 40 mm graded aggregate (For Foundation) |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Hard/dense soil. |
| 10 | Removing excavated material in Hard/dense Soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 11 | M & L RCC- M-30 (Design Mix) using 20mm graded aggregate For Footing and plinth beams |
| 12 | M & L RCC- M30 (Design Mix) using 20mm graded aggregate for Column complete all as specified and directed |
| 13 | M & L RCC- M30 (Design Mix) using 20mm graded aggregate for beams and lintels complete all as specified and directed |
| 14 | M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC Slab |
| 15 | M & L RCC- M30 (Design Mix) using 20mm graded aggregate for RCC parapet wall/drops/RCC Chajjas |
| 16 | S & F TMT bars 10mm dia & over of Grade Fe 500 incl cutting, bending, binding & placing in position with binding wirefor footings Slab beams roof slab etc complete al as specified and directed |
| 17 | Ditto as per S No 16.00 but 5 to 10mm dia in stirrups, spacers & binders. |
| 18 | M & L Form work for rough finished surfaces of concrete measured flat for For Footing |
| 19 | M & L Form work for rough finished surfaces of concrete measured flat for Column, |
| 20 | M & L use & waste Form work for rough finished surfaces of concrete measured flat for Plinth Beam |
| 21 | M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC beams sides and soffits |
| 22 | M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC Slab |
| 23 | M & L use & waste Form work for rough finished surfaces of concrete measured flat for RCC drops/Chajjas |
| 24 | M & L Pre-cast cement concrete block masonry with solid blocks Type C1 1:3:6, exc. 10 cm in width and setting in Cement mortar (1:6) mortar, complete. |
| 25 | S&F IInd class hard wood plain solid straight chowkats and framed rebated on the solid rounded put togeather with glue pinned at joints all as specified. |
| 26 | S&FPlain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 27 | S&F extruded aluminum alloy handles (150mm ) fabricated type anodised complete all as specified Make :- Shalimar / jyoti/ Classic/ Ashoka |
| 28 | S&F hinges (100 mm) stainless steel medium weight complete all as specified |
| 29 | S&F aluminum anodised barrel tower bolts (150 mm ) of extruded section complete all as specified |
| 30 | S&F 300 mm Aluminium alloy , anodised , sliding door bolt with hasp, staple (bolt type ) and fixing clips of sheet , cast , exctruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified |
| 31 | M&L of wooden surfacesof any desccription exc. 10cm width or girth incl. preparation of surfaces.applying two coats of synthetic enamel paint over one coat of primer all as specified and directed. |
| 32 | S & F powder coated aluminium sections frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 33 | M&L for Ready mix plaster 10mm thick on faces of bricks or concrete surface including including preparation of wall surfaces etc complete all as specified and directed. |
| 34 | M&L for rendering 5mm thick in ready mix plaster on ceiling surface and finishing the surfaces even and smooth without using extra cement including scrapping down and preparation of ceiling surfaces to receive plaster, scaffolding as reqd etc, complete all as specified and directed. |
| 35 | M&L for Ready mix polimer modified cement based plaster 15mm thick on new bricks or concrete surface including preparation of wall surfaces etc complete all as specified and directed. |
| 36 | Material & Labour for applying two Coats Of Oil Bound Distemper Over One Coat Of Primer on Internal Wall |
| 37 | Material & Labour for applying two Coats Of Oil Bound Distemper Over One Coat Of Primer on ceiling |
| 38 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additivesM @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 39 | M & L 75mm Thick Cement concrete ( 1:4:8 ) type D-2 (40mm graded aggregate) |
| 40 | Screed bed or bedding layer of mortar CM(1:6) 15 mm thick for laying floor finishes |
| 41 | M & L for machine cut kota stone slab flooring, 20mm thick over cement screed bas laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finish polishing all as specified and directed complete |
| 42 | M & L 75mm thick Plinth Protection PCC (1:3:6) using 20mm graded aggregate (0.75 m wide). |
| 43 | M & l for 3mm APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torched application complete and finally finished as per manufacturers instructions |
| 44 | Screed bed or bedding layer of mortar CM(1:3) 10 mm thick |
| 45 | Supply only Water Proofing compound |
| 46 | S&F aluminum anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed.Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE.(ii) Minimum thickness of anodizing shall be 15 microns. |
| 47 | Supply only 4mm thick sheet figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 Sqm in each pane etc complete all as specified and directed |
| 48 | Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed. |
| 49 | S&F for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 20mm bore complete all as specified and directed. |
| 50 | S&F in repairs Steel rolling shutters 1.25mm thick lath, with out ball bearing, as specified including top cover, locks mild steel with 4 levers, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete gear operated type with bevel gear box and crank handle. |
| 51 | Dismantling of cast iron or reinforced concrete drain pipes,200 mm jointed in cement mortar and taking out of trenches, if required complete all as specfied and directed. |
| 52 | S&F for 200 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specfied and directed. |
| 53 | M&L for concrete bed in cement concrete 1:3:6 type C2 to drain pipes of 200 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specfied and directed. |
| 54 | Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced complete all as specified . |
| 55 | M & L for cement concrete 100 mm thick type , 1 : 2 : 4 B-2 ( using 20mm graded stone aggregate) as in drain, floor etc and finishing even and smooth without using extra cement complete all as specified and directed. |
| 56 | M&L for Cement concreate type D-2 ,1 : 4 : 8 (using 40 mm, graded stone aggregate ) 75 mm thick laying in floor / paving complete all as specified and directed. |
| 57 | M&L for Chequered cement concrete tile 20CM x 20CM x 25mm thick with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over and including cement mortar bedding 20mm thick in CM 1 : 6, 15 mm thick complete all as specified and directed.. |
| 58 | M&L for crushed sand filling under floors or in foundations including watered and consolidation complete all as specfied and directed |
| 59 | M&Lfor Machine pressed precast concrete inter locking paver blocks of any shape and size conforming to IS 15658- 2006 of 60 mm thick M-35 grade with grey cement and pigment with glosey finish and including removing the existing paver blocks including removing of debries out side MD land complete all as specified and directed. |
| 60 | Sch 'A' Part I (E/M Portion)Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required |
| 61 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. |
| 62 | Supplying, fixing testing commissioning of Fire Dampers in supply air duct / main branch and return air path as and where required size including control wiring, the damper shall be motorized and spring return so as to close the damper in the event of Power failure automatically and open the same in case of power being restored. The Spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required as per specification. |
| 63 | Supplying & fixing of powder coated extruded aluminium Continuous Air Grills without aluminium volume control dampers as per specifications. |
| 64 | Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 Kg/mtr3, with 25 mm x 25 mm GI Section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and asper specification. |
| 65 | Dismantling, shifting and re-installation, testing and commissioning of water cooled type AC plant unit having capacity of 2 x 25 TR (1 x working + 1 x standby) chiller, AHU, MAin panel, AHU Panel, cooling Tower, chilled and condenser water pumps specified and directed. Please Enable Macros to View BoQ information |