| 1 | Dismantling and removing 2.5 cm thick grading concrete from roof slab cleaning the surface lowering and removing the debris within 50m lead |
| 2 | Removing old lime or cement plaster from walls , including racking out joints 12mm deep and removing the debris away from the site with all lead and lift. Including cost of all labour, sundries and T&P etc.complete in all respect as per the direction of Engineer-in-charge. |
| 3 | Removing white wash or colour wash by scraping using sand papering and preparing the surface smooth including necessary repairs to scratches etc Including cost of all labour, sundries and T&P etc.complete in all respect as per the direction of Engineer-in-charge. |
| 4 | Dismantling and removing R.C.C. columns, beams, slab, staircase, landing, lintels including stacking the useful materials for reuse and removing the debris within 50m lead |
| 5 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by manually means ,including loading , transporting, unloading to approved dumping ground within 5 Kms lead and lift.Including cost of all labour, sundries and T&P etc.complete in all respect as per the direction of Engineer-in-charge. |
| 6 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/ Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement.RCC Beams, Columns, Grider and bressmer etc. For First Floor |
| 7 | Terrace |
| 8 | RCC Floor and Foof Slab, Landing, Balconies up to 4.3 mtr. Height for First Floor. |
| 9 | Terrace |
| 10 | RCC Lintels for First Floor. |
| 11 | Terrace |
| 12 | RCC Chajjas and sunshade for First Floor. |
| 13 | Terrace |
| 14 | Providing & fixing TMT Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment.). For First Floor. |
| 15 | Terrace |
| 16 | Providing and laying Brick masonry work in Superstructure using Fly Ash bricks confirming to IS 12894 in cement mortar (1:6) after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royaltie, loading, unloading scaffolding, staging, watering and curing, sundries etc. complete as per the direction of EIC. For First Floor. |
| 17 | Terrace |
| 18 | Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.. For First Floor |
| 19 | Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. For First Floor. |
| 20 | Terrace |
| 21 | Providing 16mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. For First Floor. |
| 22 | Terrace |
| 23 | Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/ chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. For First Floor |
| 24 | Terrace |
| 25 | Providing average 25 mm thick grading Concrete with (1:2:4) using 6mm hard granite chips mixing of water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. All complete in all respect as per direction of the Engineer -in-charge. For Terrance. |
| 26 | Providing and laying Vitrified Floor Tiles confirming to IS : 15622 of of approved make, quality and colour without any warpage,with intermidiate spacers of 4 mm width laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) with intermidiate spacers of 4 mm including cutting to size, laying and filling the joints with epoxy tile grout of approved shade and colour, cleaning the surfaces with oxlaic acid, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.Make: Tiles-Kajaria/ Somany/ Equivalent. Grout-Fosroc/ Kerakoll/ Weber/ Equivalent. For First Floor. |
| 27 | Providing and laying 300 mm x 300 mm Ceramic Floor Tiles of approved make, quality and colour without any warpage,with intermidiate spacers of 4 mm width laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) with intermidiate spacers of 4 mm including cutting to size, laying and filling the joints with epoxy tile grout of approved shade and colour, cleaning the surfaces with oxlaic acid, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.Make: Tiles-Kajaria/ Somany/ Equivalent. Grout-Fosroc/ Kerakoll/ Weber/ Equivalent(Note- Sample of tiles shall be approved before procurement and use. For First Floor. |
| 28 | Providing and laying 300 mm x 300 mm Ceramic Floor Tiles of approved make, quality and colour without any warpage,with intermidiate spacers of 4 mm width laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) with intermidiate spacers of 4 mm including cutting to size, laying and filling the joints with epoxy tile grout of approved shade and colour, cleaning the surfaces with oxlaic acid, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.Make: Tiles-Kajaria/ Somany/ Equivalent. Grout-Fosroc/ Kerakoll/ Weber/ Equivalent(Note- Sample of tiles shall be approved before procurement and use. For First Floor. |
| 29 | Providing & laying granite stone flooring in Floors and landing using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. For First Floor. |
| 30 | Providing & laying granite stone tiles in dado/ skirting using 10mm thick granite stone slab of approved quality, colour and size Above 0.10 Sqm & up to 0.4 sqm to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) For First Floor. |
| 31 | Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Counters, Stair Treads, Risers, planter boxes, window sills etc over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, taxes, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use. For First Floor. |
| 32 | Providing and fixing ISI marked both side laminated flush door shutters confirming to IS 2202(Part 1) of 34mm thickness with approved colour paint over a coat of primer etc including ISI marked necessary hardware fittings such as, SS Concealed Hinges (6\\"), stopper, Door eye & magnet, SS Tower bolt-8\\", Mortise lock Handle, Cylinder coin & knob key & knob, SS lock body etc. including cost of all labours, materials, conveyance, hardware fixing, loading and unloading and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. For First Floor. |
| 33 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer using M.S. angles 40x40x6 mm for diagonal braces.etc including cost of all labours, materials, conveyance, hardware fixing,loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. For Terrace |
| 34 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge. For First Floor. |
| 35 | Supply and fixing of UPVC Sliding glazed Window made out of hollow multi-chambered uPVC sections having isolated drainage system with the design 3 Track 3 Panel System. The 2 track outer frame of the window having over all size of 98 x 52 mm (with mosquito mesh) having internal wall thickness of 2.50 mm. The glass sashes / shutters shall be made out of Upvc sections with over all size of 42 x 70 mm with internal thickness of 2.50 mm. The mosquito mesh shutter having over all size of 25 x 52 mm with internal wall thickness of 2.50 mm. Reinforcement of galvonised mild steel with thick ness of 1.50 mm has to put through out the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight and unmoved. Single point locking system (called touch lock) made out of casted zamac with white powder coated and locking hook will make of SS 304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon an having capacity of 40 - 120 kg depends on glass weight. Finseal will be provided to protect the dust in between closing point & interlocking point of glass & mesh shutters. The Interlock of the uPVC window should be approved by the Engineer-in- charge before fixing. Glass thickness and colour can be changed as per requirement. For First Floor. |
| 36 | Terrace |
| 37 | Supply and fixing of UPVC Top Hung glazed uPVC ventilator made out of hollow multi chambered uPVC sections having isolated drainage system with the design Casement (Outside open) The casment frame of the window having over all size of 60 x 52 mm having internal wall thickness of 3.00 mm. The glass panel shall be made out of Upvc sections with over all size of 52 x 78 mm with internal thickness of 3.00 mm. Reinforcement of galvonised mild steel with thickness of 1.20 mm has to put throughout the frame, glass panel. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight. Single point locking system (called Cockspur) made out of casted zamac with white powder coated and Friction and Stray Hinges will be made of SS 304 grade material. Multipoint locking system (called Espag) made out of casted zamac with white powder coated can be used if height goes beyond 4.50 feet. The model and brand of the uPvc window shall be approved by the Engineer -in- charge before fixing. Glass thickness and colour will be change as per requirement. For First Floor. |
| 38 | Supplying, Fitting and Fixing M.S works of approved designs made out of M S Flat, hollwo section, i Section, Square bars/ Round bars etc. in railings, grills, gates etc of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. For First Floor. |
| 39 | Supplying, fitting and fixing of stainless steel of 304 grade in hand rail using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mt c/c and stainless square pipe bacing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance,of all materials, labour T&P etc. required for the complete in all respect as per the direction of Engineer -in- charge. For First Floor. |
| 40 | Providing and Painting two coats with synthetic enamel paint of approved make, quality and shade on new Steel work to give an even shade over an under coat of primer of approved brand and manufacturer including the cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, T&P, etc, all complete as per the direction of Engineer-in-charge.(Note- colour and shade shall be approved before procurement and use.) For First Floor. |
| 41 | Providing and applying 2 coats of Plastic Emulsion Paint of approved quality and shade over a coat of putty & wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats,including of all materials, labour, conveyance, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) For First Floor. |
| 42 | Terrace |
| 43 | Providing and applying two coats of Weather Coat Paint of approved make, quality and shade to the external surface of the building over a coat of primer after finishing wall surface of walls with Acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting of approved shade and quality after cleaning the plastered surface perfectly by watering and brushing including cost of material, putty, paint, brushes, all labour, taxes, loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) For First Floor. |
| 44 | Terrace |
| 45 | Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand : 2 graded stone aggregate 6 mm nominal size chips) for coping, including the cost of centering, shuttering and finishing including placing two nos. of 8 mm dia Fe 500 grade reinforcement bars suitably as per the approved drawings including the cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer -in-charge. For Terrance. |
| 46 | Providing and fixing Glass Reinforced Concrete (G.R.C) Jallis in approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick casted with layering technique Power Spray methodology have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens casting shall take place with layering methodology using- Direct Power Spray machines. The screens shall be casted from ‘53 grade’ White Portland Cement fine graded, sieved Quartz & Silica Sand, reinforced with Alkali Resistant Glass Fiber manufactured between 4-5% having Zirconia content at least 16%, Super Plasticizers and U.V resistant Synthetic inorganic pigments should be used. |
| 47 | Providing & Installing external cladding using fibre cement plank manufactured by wet recessed autoclaved technology uncolored plank teak texture (External Grade) thickness 8mm and dimension 150mmX3000mm. The Fibre cement plank should be of minimum density 1300kg/ m3 (±50) and comply to ASTM C 1185 and ISO 8336 part (E) for confirming durability properties and BS 476 – part 5, 6 & 7, Thermal conductivity should be minimum 0.15 W/m˚K and PH value should be in the range of 7 – 8. ).Depending on height of structure planks to be fixed using Aluminum frame section of 50mm x 25mm of suitable gauge (within1mm thick) with minimum spacing 450mm to 600mm or as per direction of Engineer In charge. Uncolored teak planks to be fixed using screws of Tensile strength 34N and Shear strength 68N on framing. Screw heads are covered with acrylic putty of the next plank giving uniform natural groove/over lap(as per approved drawing ). All plank to plank joints to be staggered & finished with one coat of cement based primer on all side, with 2 coats of water based acrylic paint of approved shade. . |
| 48 | Providing and fixing Aluminium Composite Panels (ACP) of exterior grade forcladding near entrance of Alucobond / Alstrong / Eurobond or approved equivalent make for external wall / column / canopy cladding in combination of solid / Metallic colours, including all necessary frame work and complete weather sealing. The composite panel should consist of 3mm thermoplastic core of LDPE sandwiched between 2 skins of 0.5mm thick aluminium sheet (alloy designation 310S) making a total panel thickness of 4mm. The surface will be furnished with Lumiflon based flourcarbon coating on top sides and service coating on reverse side. Coatings shall conform to specifications of specifications of ECCA / AAMA and conforming to the mechanical properties of panel as per detailed technical specifications. the system shall be fixed using GI brackets and stainless steel bolts and nuts complete with spring washers and cap nuts and all other necessary accessories. The bracket support shall be designed as per manufactures specification and shall withstand a wind pressure of 150 kg / sqm. all hardware shall corrosion resistant frame out of anodised aluminium member. |
| 49 | PH works |
| 50 | Electrification works |
| 51 | Contingencies Please Enable Macros to View BoQ information |