| Sl. No. | Item Description |
| 1 | GROUND FLOOR |
| 2 | Providing of dismantaling of existing building & cleaninh site with machine including shifting of debrises by transport vehicles as directed by the Engineer-in-charge. |
| 3 | Earth work in ordinary soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer-in-charge. |
| 4 | Filling Foundation and plinth with sand including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 5 | Cement concrete with C.C ( 1:4:8) with 40 mm size metal including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 6 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in foundation including cost, conveyance, royality etc complete as direction by EIC. |
| 7 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in Superstructure including cost, conveyance, royality etc complete as direction by EIC. |
| 8 | R.C.C. work M-20 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying with Centering & shuttering as direction of EIC. |
| 9 | Footing (M20) |
| 10 | Column (M20) |
| 11 | Plinth Beam (M20) |
| 12 | Lintal (M20) |
| 13 | Roof Beam (M20) |
| 14 | Chhaja (M20) |
| 15 | Staircase (M20) |
| 16 | Roof Slab (M20) |
| 17 | Providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge etc complete as direction by EIC.. |
| 18 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 19 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment including cost, conveyance, royality of all materials etc complete as direction by EIC.. |
| 20 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 21 | Supplying, fitting and fixing of M.S. works including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect as direction by EIC. |
| 22 | Window Grill |
| 23 | Grill |
| 24 | Providing and fixing of factory made UPVC 2/3-track sliding/3-track window (white colour) complete,comprising multi-chambered frame 60 mm of size 67x54 with wall thickness of 2.3mm having in built roller track on top complete in all respect as direction by EIC |
| 25 | Providing and fixing of fluse door with chukatha required fitting & fixture complete in all respect as direction by EIC |
| 26 | Fixing vitrified tiles in floors on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 27 | Fixing Granite slab in steps on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 28 | Painting two coats to the wall surface by using 100% premium Acrylic emulsion paint to interior wall (distmper)surface over a coat of primer with water bond cement primer after preparing the surface smooth by applying putty punning with Synthetic Acrylic wall putty including finishing the surface smooth by sand papering in all heights etc. complete in all respect.any approved shade including cost conveyance royality etc complete as per direction of EIC |
| 29 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) exterior grade(weather coat) over a coat of primer with water bond cement primer applying putty punning with Synthetic Acrylic wall putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 30 | Painting 2 coats with any enamel paint on new work over primer including cost of paint & primer , labour. over a coat of priming including all costs of labour ,Paint, primer, brushes and putty required for the work etc complete and as per direction of Engineer-in-charge. |
| 31 | Supplying ,fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx32mm in three rows in staircase as per approved design and specification,buffing,polishing etc.with cost conveyance,of all materials,labour,T&P etc required for the complete in all respects. |
| 32 | B.FIRST FLOOR |
| 33 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in Superstructure including cost, conveyance, royality etc complete as direction by EIC. |
| 34 | R.C.C. work M-20 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying with Centering & shuttering as direction of EIC. |
| 35 | Column (M20) |
| 36 | Lintal (M20) |
| 37 | Roof Beam (M20) |
| 38 | Chhaja (M20) |
| 39 | Staircase (M20) |
| 40 | Roof Slab (M20) |
| 41 | Providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge etc complete as direction by EIC.. |
| 42 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 43 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment including cost, conveyance, royality of all materials etc complete as direction by EIC.. |
| 44 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 45 | Supplying, fitting and fixing of M.S. work including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect as direction by EIC. |
| 46 | Window Grill |
| 47 | MS Door |
| 48 | MS Grill |
| 49 | Fixing Viritified tiles in floors on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 50 | Fixing Granite Slab in steps on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 51 | Providing and fixing of factory made UPVC 2-track sliding/3-track window (white colour) complete,comprising alluminium multi-chambered frame 60 mm of size 67x54 with wall thickness of 2.3mm having in built upvc roller track on top and upvc etc. and direction of engineer in charge. |
| 52 | Providing and fixing of Fluse door including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 53 | Painting two coats to the wall surface by using 100% premium Acrylic emulsion paint to interior wall (distmper)surface over a coat of primer with water bond cement primer after preparing the surface smooth by applying putty punning with Synthetic Acrylic wall putty including finishing the surface smooth by sand papering in all heights etc. complete in all respect.any approved shade including cost conveyance royality etc complete as per direction of EIC |
| 54 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) exterior grade(weather coat) over a coat of primer with water bond cement primer applying putty punning with Synthetic Acrylic wall putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 55 | Painting 2 coats with any enamel paint on new work over primer including cost of paint & primer , labour. over a coat of priming including all costs of labour ,Paint, primer, brushes and putty required for the work etc complete and as per direction of Engineer-in-charge. |
| 56 | Supplying ,fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx32mm in three rows in staircase as per approved design and specification,buffing,polishing etc.with cost conveyance,of all materials,labour,T&P etc required for the complete in all respects. |
| 57 | Supply of office furnitures with cost conveyance,of all materials,labour,T&P etc required for the complete in all respects. |
| 58 | C.ELECTRIFICATION WORKS |
| 59 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard ) |
| 60 | Group A |
| 61 | Group B |
| 62 | Group C |
| 63 | Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. (Make of wire: finolex/ Anchor/Havels/L&T/KDK) Average Length: 3 mtr |
| 64 | Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer in Charge. |
| 65 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C |
| 66 | Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge. |
| 67 | Recessed wiring for 3 x 6 amp socket outlet controlled by 1nos 16Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge. |
| 68 | Point wiring for AC/ Projector/ Geyser socket outlet with 16A plug socket and 16A control switch at nearest separate location . |
| 69 | Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge. |
| 70 | Recessed wiring for A.C socket outlet with industrial type socket outlet, plug top and metal chained cover in sheet steel enclosure ,20A/32A SP MCB including all accesories and connection as per direction of Engineer in Charge. |
| 71 | Recessed wiring for 3 Phase Industrial socket outlet with 32 amp TPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure indusrial socket ,32A 4P MCB including all accesories and connection as per direction of Engineer in Charge. |
| 72 | Surface wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I modular box with face plate & cover of suitable size including 1 no 5A switch for lift well light control and all accesories and connection as per direction of Engineer in Charge. |
| 73 | Recessed wiring to submain in 4 x 16 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For PDB ) |
| 74 | Recessed wiring to submain in 4 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For EQUIPMENT DB ) |
| 75 | Recessed wiring to submain in 4 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For LDB & 32A IND SOCKET ) |
| 76 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For 2TR. AC SOCKET ) |
| 77 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For 1.5TR A.C/ GEYSER POINTS ) |
| 78 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From DB to Switch Board .COMPUTER & PROJECTOR POINTS and 15A SOCKETs ) |
| 79 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For looped Switch Boards ) |
| 80 | Supply and fixing of following way three/single pole and neutral, sheet steel, MCB distribution, 415/240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS and blank module plates as required. |
| 81 | 6way TPN Horizontal Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with Incommer 1 No-40A 4P RCCB (100mA) Outgoings-6-32 A SP MCB-18Nos,(L&T/ Schneider) .LDB |
| 82 | 4wayTPN Horizontal Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with Incommer 1 No-63A 4P RCCB (100mA) Outgoings-6-32 A SP MCB-12Nos,(L&T/ Schneider) .PDB |
| 83 | 4 wayTPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with Incommer 1 No-40A 4P RCCB (100mA) Outgoings-6-32 A SP MCB-12Nos,(L&T/ Schneider) . EQUIPMENT DB |
| 84 | Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4way SPN Distribution Boards suitable for 240 V, Single phase, 2 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-32A 4P MCB (10KA) (L&T/ Schneider) . LIFT DB |
| 85 | Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required of approved make as directed by EIC |
| 86 | Provision for 3 phase eletriccal connection complete as required or directed by EIC. |
| 87 | PANNEL & DISTRIBUTION BOARD. Supply, delivery, installation, testing & commissioning of L.T. indoor floor/ wall mounted type distribution boards made out of 2 mm thick CR sheet metal cubicle fixed on m.s. channel base, duly acid treated for dusting, primered and painted with 2 coats of powder coating of approved shade dust, damp & vermin proof. Having hinged door and compartmental arrangement for each equipment & busbar chamber on the top of the panel running horizontally having provision for cable conduit entry earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of EIC. |
| 88 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting of all sizes complete with all accessories and tube etc. directly on ceiling wall, including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 89 | 15 W LED Lamp Equiv. to PHILIPS or any approved make as directed by EIC. |
| 90 | Ceiling mounted indoor type PICTURE LED Luminaire with LED Lamp Similar to PHILIPS or any approved make with 15 watt LED or equivalent as directed by EIC. |
| 91 | Supplying and fixing of Celling Fan complete as required. |
| 92 | Providing & Fixing of . 2 Ton capacityA.C Machine of any reputed make. |
| 93 | 30 W LED street light |
| 94 | Provision for 65 kv Tansaformor |
| 95 | Supply,Installation,Testing and commissioning of LED Sinage with all fitting fixtures as required |
| 96 | Provision for Street light |
| 97 | Provision for decorative light |
| 98 | D.INTERNAL PH & SANITARY WORKS |
| 99 | Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china floor mounted water closet (European pattern) 'P' or 'S' type of approved make, As per IS-2556 with ISI mark, including supply of sutaible PVC wall plug and Brass screws etc. all complete including cost of PVC seat cover (solid) with hinges & rubber buffers etc with low level pvc cistern. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make : JAQUAR/HINDWARE/CERA/PARRYWARE |
| 100 | Gents urinal |
| 101 | Providing all materials, labour, and T&P for fitting and fixing of 10 liter capacity PVC low level cistern complete with all internal fittings of approved make as per IS-7231 with ISI mark and Providing of necessary PVC wall plug, screws and 15mm dia PVC connection pipe with union at both end ,including testing etc. all complete as per specification & direction of Engineer-in-charge. Make : JAQUAR/HINDWARE/CERA/PARRYWARE |
| 102 | Supply all materials and labour for fitting and fixing of 560x410mm white glazed vitreous china oval wash hand basin of approved make with supply & fixing of 32mm CP waste,15mm dia PVC water connection pipe, basin bolts & Nuts of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4) etc. with all taxes, duties, transportation etc. all complete as per direction of EIC. (Make:JAQUAR/HINDWARE/CERA/PARRYWARE) |
| 103 | Providing and fixing 15mm dia CP angular stop cock |
| 104 | Providing and fixing 15mm dia CP two way bib cock |
| 105 | Providing and fixing Hand Faucet |
| 106 | Providing and fixing15mm dia pillar cock |
| 107 | Providing and fixing32mm CP Bottle Trap |
| 108 | Providing and fixingStainless steel jali grating with hole of floor / trap |
| 109 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste water pipes conforming to IS:13592 Type-B, including jointing with seal-ring conforming to IS:5382, Make : SUPREME/ASTRAL/ASHIRVAD |
| 110 | 110mm dia |
| 111 | 160 mm dia PVC waste pipe |
| 112 | Supplying all materials, labour, T&P, fitting and fixing of following dia UPVC SWR fittings of approved make confirming to IS-14735 with all taxes, duties, transportation & requisite testing as per specification & direction of Engineer-in-charge. Make : SUPREME/ASTRAL/ASHIRVAD |
| 113 | 110mm x110mm P trap/S trap |
| 114 | 110mm WC Connector/ Bend with lip ring |
| 115 | 110mm dia Plain Bend 87.5 deg |
| 116 | 110 mm dia PVC floor trap |
| 117 | 110mm dia single y with out door |
| 118 | 110mm dia sweept tee with door |
| 119 | 110mm dia Bend 87.5 deg with door |
| 120 | Providing and fixing Clorinated Polyvinyl Chloride (CPVC) pipes SDR-13.5 conforming to IS: 15778, having thermal stbility for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. The includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Make : SUPREME/ASTRAL/ASHIRVAD |
| 121 | 20mm Dia |
| 122 | Cutting holes in 250mm thick brick masonry wall for taking PVC pipes through and mending good the damages |
| 123 | 5000 Ltr Over Head Tank with brick massonary stand with complete all respect. With reputaed make |
| 124 | Providing, Fixing, testing & commissioning of ABS Rinsing spray (Health Faucet) with regulator of approved quality with flexible pipe 1.5 m long, wall hooked complete as required.Model Jaquar ALD-CHR-579 OR As Approved by EIC |
| 125 | Providing, Fixing, testing & commissioning of 1.5 HP Sumrsible Pump & including 6\\" dia Borwell. |
| 126 | Providing, Fixing, testing & commissioning of 125 ltr Aquaguard including all fitting |
| 127 | Provision for Irrigation of Plantation including all fitting |
| 128 | E.GODOWN |
| 129 | Providing of dismantaling of existing building & cleaninh site with machine including shifting of debrises by transport vehicles as directed by the Engineer-in-charge. |
| 130 | Earth work in ordinary soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer-in-charge. |
| 131 | Filling Foundation and plinth with sand including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 132 | Cement concrete with C.C ( 1:4:8) with 40 mm size metal including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 133 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in foundation including cost, conveyance, royality etc complete as direction by EIC. |
| 134 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in Superstructure including cost, conveyance, royality etc complete as direction by EIC. |
| 135 | R.C.C. work M-20 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying with Centering & shuttering as direction of EIC. |
| 136 | Footing (M20) |
| 137 | Column (M20) |
| 138 | Plinth Beam (M20) |
| 139 | Lintal (M20) |
| 140 | Roof Beam (M20) |
| 141 | Chhaja (M20) |
| 142 | Staircase (M20) |
| 143 | Roof Slab (M20) |
| 144 | Providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge etc complete as direction by EIC.. |
| 145 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 146 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment including cost, conveyance, royality of all materials etc complete as direction by EIC.. |
| 147 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 148 | Supplying, fitting and fixing of M.S. works including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect as direction by EIC. |
| 149 | Window Grill |
| 150 | Shutter |
| 151 | Providing and fixing of factory made UPVC 2/3-track sliding/3-track window (white colour) complete,comprising multi-chambered frame 60 mm of size 67x54 with wall thickness of 2.3mm having in built roller track on top complete in all respect as direction by EIC |
| 152 | Fixing vitrified tiles in floors on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 153 | Fixing Granite slab in steps on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 154 | Painting two coats to the wall surface by using 100% premium Acrylic emulsion paint to interior wall (distmper)surface over a coat of primer with water bond cement primer after preparing the surface smooth by applying putty punning with Synthetic Acrylic wall putty including finishing the surface smooth by sand papering in all heights etc. complete in all respect.any approved shade including cost conveyance royality etc complete as per direction of EIC |
| 155 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) exterior grade(weather coat) over a coat of primer with water bond cement primer applying putty punning with Synthetic Acrylic wall putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 156 | Painting 2 coats with any enamel paint on new work over primer including cost of paint & primer , labour. over a coat of priming including all costs of labour ,Paint, primer, brushes and putty required for the work etc complete and as per direction of Engineer-in-charge. |
| 157 | Supplying ,fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx32mm in three rows in staircase as per approved design and specification,buffing,polishing etc.with cost conveyance,of all materials,labour,T&P etc required for the complete in all respects. |
| 158 | Provision of internal eletrificition omplete and as per direction of Engineer-in-charge. |
| 159 | Provision of MS Racks for stock of tasar coocons complete and as per direction of Engineer-in-charge. |
| 160 | F.COOKING SHED |
| 161 | Earth work in ordinary soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer-in-charge. |
| 162 | Filling Foundation and plinth with sand including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 163 | Cement concrete with C.C ( 1:4:8) with 40 mm size metal including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 164 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in foundation including cost, conveyance, royality etc complete as direction by EIC. |
| 165 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in Superstructure including cost, conveyance, royality etc complete as direction by EIC. |
| 166 | R.C.C. work M-20 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying with Centering & shuttering as direction of EIC. |
| 167 | Footing (M20) |
| 168 | Column (M20) |
| 169 | Plinth Beam (M20) |
| 170 | Lintal (M20) |
| 171 | Roof Beam (M20) |
| 172 | Chhaja (M20) |
| 173 | Roof Slab (M20) |
| 174 | Providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge etc complete as direction by EIC.. |
| 175 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 176 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment including cost, conveyance, royality of all materials etc complete as direction by EIC.. |
| 177 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 178 | Supplying, fitting and fixing of M.S. works including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect as direction by EIC. |
| 179 | Window Grill |
| 180 | MS Door |
| 181 | Providing and fixing of factory made UPVC 2/3-track sliding/3-track window (white colour) complete,comprising multi-chambered frame 60 mm of size 67x54 with wall thickness of 2.3mm having in built roller track on top complete in all respect as direction by EIC |
| 182 | Fixing vitrified tiles in floors on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles etc complete as per specification and direction of engineer in charge. |
| 183 | Painting two coats to the wall surface by using 100% premium Acrylic emulsion paint to interior wall (distmper)surface over a coat of primer with water bond cement primer after preparing the surface smooth by applying putty punning with Synthetic Acrylic wall putty including finishing the surface smooth by sand papering in all heights etc. complete in all respect.any approved shade including cost conveyance royality etc complete as per direction of EIC |
| 184 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) exterior grade(weather coat) over a coat of primer with water bond cement primer applying putty punning with Synthetic Acrylic wall putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 185 | Painting 2 coats with any enamel paint on new work over primer including cost of paint & primer , labour. over a coat of priming including all costs of labour ,Paint, primer, brushes and putty required for the work etc complete and as per direction of Engineer-in-charge. |
| 186 | Provision of internal eletrificition works omplete and as per direction of Engineer-in-charge. |
| 187 | Provision of internal PH & Sanitary works omplete and as per direction of Engineer-in-charge. |
| 188 | G.COMPOUND WALL |
| 189 | Earth work in ordinary soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer-in-charge. |
| 190 | Filling Foundation and plinth with sand including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 191 | Cement concrete with C.C ( 1:4:8) with 40 mm size metal including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 192 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in foundation including cost, conveyance, royality etc complete as direction by EIC. |
| 193 | Brick work withFly ash bricks 25 cm x 12 cmx8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance +8 percent in cement mortar (1:6) in Superstructure including cost, conveyance, royality etc complete as direction by EIC. |
| 194 | R.C.C. work M-20 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying with Centering & shuttering as direction of EIC. |
| 195 | Footing (M20) |
| 196 | Column (M20) |
| 197 | Plinth Beam (M20) |
| 198 | Providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge etc complete as direction by EIC.. |
| 199 | Supplying, fitting and fixing of M.S. works including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect as direction by EIC. |
| 200 | 16 mm thick cement plaster over fly ash Brick Masonery with C.M ( 1:6) over work including cost, conveyance, royality of all materials etc complete as direction by EIC. |
| 201 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) exterior grade(weather coat) over a coat of primer with water bond cement primer applying putty punning with Synthetic Acrylic wall putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 202 | Painting 2 coats with any enamel paint on new work over primer including cost of paint & primer , labour. over a coat of priming including all costs of labour ,Paint, primer, brushes and putty required for the work etc complete and as per direction of Engineer-in-charge. |
| 203 | Supplying ,fitting and fixing of round type blede wire on top compound wall.with cost conveyance,of all materials,labour,T&P etc required for the complete in all respects. |
| 204 | H.INTERNAL PATHWAYS |
| 205 | Filling sand with compacted bed and proper embedding laying for cocrete paver blocks including cost, conveyance, royality etc complete as directed by the Engineer-in-charge. |
| 206 | Providing and laying factory made cement concrete paver blocks of 60mm & 80mm thick and M-30 grade of concrete of required strength,thickness & size/shape made by table vibratory methrod.to attain superior smoth finish using PU or equivalent moulds.laid in required Gray/Red/Yellow & pattern over 50mm thick compacted bed of sand,compacting and propoer embedding/laying of inter locking paver blocks in to sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per required size and pattern,finishing and sweeping extra sand in footpath,parks,lawns,drive ways or parking etc.including cost of all materials,labour,royalties,conveyance etc,complete in all respect as directed by the Engineer-in-charge. |
| 207 | Providing and laying factory made cement concrete kerb stone for protection laying paver with concrete base & cement mortor joints including primming andyellow white colouring on footpath,parks,lawns,drive ways or parking etc.including cost of all materials,labour,royalties,conveyance etc,complete in all respect as directed by the Engineer-in-charge. |
| 208 | Supplying,fixing and installition of concrete sitting bench as per the approved drawing including cost of all materials,labours,royalites,conveyance complete in all respect as direction by Enginner-in-charge. |
| 209 | Provision of landscaping complete in all respect as direction by Enginner-in-charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy