| 1 | Taking down chowkhats with shutter (without taking off shutters from the frame) area not exc. 1.50 Sqm each complete all as specified and directed. |
| 2 | Taking down chowkhats with shutter (without taking off shutters from the frame) area exc. 1.50 Sqm but n.exc 4.00 sqm each complete all as specified and directed. |
| 3 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed. |
| 4 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed. |
| 6 | Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 7 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 8 | Dismantling of wall and ceiling boards of any type and any thickness including cover fillets complete all as specified and directed. |
| 9 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge. |
| 10 | Dismantling brick/concrete tiles any size etc including existing roof treatment of any thickness complete all as specified and directed. |
| 11 | S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge. |
| 12 | Providing and fixing factory made uPVC white color Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Cont/- |
| 13 | Cont/- Hardware included : [Touch Lock of zinc alloyed (white powder coated), steel roller system including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for three track sliding frame, wool pine for Sliding sash and interlock. Area Exc 2.00 Sqm each. complete all as specified and directed by Engineer-In-ChargeNote : The unit rate quoted by contractor includes cost of glass and wire mesh and includes all other connected accessories Net opening will be measured for payment purpose. |
| 14 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). door profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, Cont/- |
| 15 | Cont/-frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware included: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) and 5mm thick glazing with selected quality glass. complete all as specified and directed Note : The unit rate quoted by contractor includes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose. |
| 16 | M&L for vitrified ceramic coloured double charge joint free tiles 9-10mm thick (square/ rectangular) polished area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed in CM (1:4) complete all as specified and directed. |
| 17 | All as per item No 14.00 (here-in-before) above but as in skirting over 10mm thick backing coat in CM (1:3) complete all as specified and directed. |
| 18 | M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate) as in floor finishes and leveling course complete all as specified and directed. |
| 19 | M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 20 | All as per Srl item No 17.00 here-in-before but except brick.Note : Old serviceable brick retrieved from serial item No 6.00 of BOQ here-in-before shall be used under this item. |
| 21 | M&L for rendering 15 mm thick in CM 1:4 including water proofing compound on fair face of brick or concrete surface, finished even and fair without using extra cement complete all as specified and directed.Note:- WPC shall be measured and paid saperately. |
| 22 | Supply only liquid water proofing compound of approved complete all as specified and directed. |
| 23 | M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished surface fair and even complete all as specified and as directed. |
| 24 | M&L for rendering 5mm thick in CM (1:4) as on ceiling complete all as specified and directed. |
| 25 | M&L for applying a coat of two component elastomeric acrylic polymer modified cementitious water proofing coating, having properties of 80 % elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications and sprinkle sand at 10-15 gram per sqft for better grip with plaster complete all as specified and directed. |
| 26 | M&L preparation of new plastered surfaces of wall and applying two coats of destempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gm/litre of approved manufacturer, of required shade and colour over a coat of wall care putty complete as per manufacturer specification complete all as specified and directed. |
| 27 | M&L preparation of new plastered surfaces for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.90 litre/10 Sqm complete all as specified and directed. |
| 28 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 29 | M&L for complete removal of existing treatment and preparation of old treated surfaces of wall for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.90 litre/10 Sqm complete all as specified and directed. |
| 30 | M&L for complete removal of existing treatment and preparation of old treated surfaces of wall for applying two coats of distempering with 1st quality acrylic distmper (ready mixed) having VOC content less than 50gm/litre of approved manufacturer, of required shade and colour over a coat of wall care putty complete as per manufacturer specification complete all as specified and directed. |
| 31 | M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge. |
| 32 | M&L for 75 mm thick PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge.Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item complete all as spcified and directed. |
| 33 | Dismantling loose/disintegrated portion of RCC Chajjas, bands, shelves, beams, coloumn or slab and similar work including support if required and stitching of cracks with MS U clamps of 8mm dia @ 150mm c/c with inserting concrate block strecthner with cement mortar (1:3) mixed with adhesive chemical (polymer based) and reinforced with PVC chicken mash formwork including where ever required and finished with 10mm thick plastering in CM (1:4) finished even & smooth without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed. |
| 34 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling with semi perforated 12mm thick micro tegular edged GRG False ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm Cont/- |
| 35 | Cont/-and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40 mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. |
| 36 | S&F hollow corrugated shape PVC wall lining consisting of 5mm thick decorative colour PVC sheet inclusive of solvent cement and fixing and incl beading at sides on PVC frame as per specifications all as specifed complete all as specified and directed. |
| 37 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including 20mm screed bedding in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 38 | M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for water proofing treatment with APP modified bituminous membrane 3mm thick consisting of the following for RCC roof :-(a) Cleaning palstered roof surfaces and applying a coat of oxidised bitumen based solvented primer a@ 0.3Kg /Sqm of approved make on top of dry surface of RCC roof complete all as specified and directed.(b) M&L for APP modified polymeric water proofing membrance 3mm thick weight not less than 3.0 Kg/Sqm with non woven polyster core of approved make applied by heating one surface of membrane with LPG torch with lap of 100mm and the overlap shall be sealed by flame complete all as specified and directed. |
| 40 | S&F precast hydraulically pressed PCC tiles of size 30cm x 30cm x 20mm thick laid over and including screed bed 15mm thick in CM (1:4) set and jointed in neat cement slurry and pointed in CM (1:3) mixed with WPC of approved make in screed bed and pointing on roof complete all as specified and directed. |
| 41 | M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate as in chajjas etc complete all as specified and directed. |
| 42 | Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed. |
| 43 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 44 | Taking down surface / concealed copper / aluminium point wiring (light, bell, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators, tubelight fittings etc and making good disturbed surfaces with plaster on walls, floors etc complete all as specified and directed. |
| 45 | M&L for Point wiring complete with 1.5 sqmm single core FRLSH PVC insulated cable with multi stranded copper condutor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for surface or concealed conduit as directed at site incl chase cutting for one light / fan point / bell point / fan point / exhaust fan controlled by one one way switch including MS sheet sunken box concealed on wall duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 1.5 sqmm multi stranded FRLSH, PVC insulated copper cable as continuous earth connected to common earth and earth dolly including making good the disturbed surfaces complete all as specified and as directed. |
| 46 | All as per serial item No. 42.00 here-in-before but for One 3 pin 5 Amp socket outlet on independent board. |
| 47 | All as per serial item No. 42.00 here-in-before but for One 5 pin 5 Amp socket outlet on the same board with other switches. |
| 48 | All as per Sl item No 42.00 above herein before but for one bell point controlled by one bell push. |
| 49 | M&L for point wiring with 2.5 sqmm PVC insulated, unsheathed FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all and including conduit fittings and fixing accessories 1.2mm thick sunken anodised pressed steel terminal boxes with 3.0 mm thick hylam sheet cover for mounting switches, socket etc including 2.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for one socket 16 Amp socket outlet controlled by one switch on independent board.complete all as specified and directed. |
| 50 | S & F bell ding dong AC 240 volts, single phase complete all as specified and directed. |
| 51 | S & F modular bell push, 6 Amp 240 volt one module complete all as specified and directed. |
| 52 | S & F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed. |
| 53 | S & F modular type 2/3 pin 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 54 | S & F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. |
| 55 | S & F modular type 2/3 pin 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 56 | S & F modular type 3/5 pin socket with one Single pole MCB 20 Amp 230 volt including concealing in wall suitable for AC and domestic appliances complete all as specified and directed. |
| 57 | S & F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed. |
| 58 | S&F Angle / batten holder polycorbonate type body suitable for batten fitting complete all as specified and directed. |
| 59 | S&F LED bulb of capacity 10/12 watts not less than 700 lumens output at 6500K colour temp, complete all as specified and directed. |
| 60 | S&F ceiling rose 63x30 mm three terminal, polycorbonate body complete all as specified and directed. |
| 61 | S&Fin repair LED wall light, stainless steel, brushed nickel, frosted glass with base cap B22, height 235mm, length 120mm single phase 220 V complete all as specified and directed. |
| 62 | Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 63 | S&F in replacement LED (1.2m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 2000 lumen/20 watt at a minimum system efficacy of 2000 lumen per 20 watt and total power consumption not more than 20 watt including driver of capacity 10 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10\\"%\\" AND PF>0.95 complete all as specified and directed. |
| 64 | S&F in replacement LED (0.6m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 1150 lumen/10 watt at a minimum system efficacy of 1150 lumen per 10 watt and total power consumption not more than 10 watt including driver of capacity 5 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10\\"%\\" AND PF>0.95 complete all as specified and directed. |
| 65 | Supply & fixing in replacement security light with LED street light, 35 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class-I in pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatment High efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13 alongwith arm with single arm bracket OD 58 mm (max) with clamp, nut, bolts etc mounted on wall complete in all respect complete all as specified and directed. |
| 66 | S&F in repair 10W integrated LED bulk head luminaire environment friendly, ultra modern, energy saving, surface mounted decorative oval bulk head with LED light, complete all as specified and directed. |
| 67 | S & F in repair LED flood light ,100 watt, 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete all as specified and directed |
| 68 | S & F in repair ENTECH signs & display EXIT red colour safety sign 5 inch height contour light box complete all as specified and directed. |
| 69 | S & F in repair picture light brushed nickel for display warm white 7 watt complete all as specified and directed. |
| 70 | M & L concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same including taking down old unserviceable cable complete all as specified by Engr- in- Charge.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 71 | M & L concealed sub main wiring with 2 runs of 10 sqmm main wire along with 1 run of 10 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same including taking down old unserviceable cable complete all as specified by Engr- in- Charge.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 72 | Supply & fixing in replacement sheet metal enclosure MCB distribution board Single Pole & Neutral 240 volts 12 way with 200 Amp rated bus bar double door with isolated Neutral bar & shrounded bus bar IP-42 having door earthing complete all as specified and directed. |
| 73 | Supply & fixing in replacement of MCB Single Pole Neutral 240 volt any rating from 32 to 63 amps, C series with rupturing capacity 10 KA complete all as specified and directed. |
| 74 | Supply & fixing in replacement of MCB single pole 240 volt any rating from 6 to 32 amps, C series with rupturing capacity 10 KA complete all as specified and directed. |
| 75 | Supply and fixing in replacement exhaust fans 300 mm sweep metallic body, heavy duty, four blade, double ball bearing, 1400 RPM, minimum air delivery discharge 1700 CMH suitable for SP, 230/250V, 50 Hz AC supply with protective bird guard with louver shutters including grouting of frame in wall and connecting with and including 3 run 1.5 Sq mm single core, PVC insulated but unsheathered FRLSH multistranded copper conductors cable from ceiling rose to exhaust fan complete all as specified and directed.Note : Old unserviceable exhaust fan shall be deposited in AGE E/M store yard. |
| 76 | S&F in repalcement Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V, 5 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and directed.Note : Old unserviceable exhasut fan shall be deposited in AGE E/M store yard. |
| 77 | M&L for in replacement earthing with galvanised steel earth plate elctrode 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr below GL) with the toop edge of the plate not less than 1.5 mtr below the normal group level connected to GI earth srtip of size 25x4mm thick soldered and riveted to earth plate,GI earth strip will be protected by using 50mm bore GI pipe (light grade) earth plate to equipment and watering pipe 20mm bore (light grade) and chamber/pit in PCC(1:3:6) type C1 using 20mm graded stone aggregate with precast RCC pit cover 50mm thick in (1:2:4) type B1using 20mm graded stone aggregate reinforced with 8mm dia MS TMT bar at 80mm c/c both way with lifting hook made out of 8mm dia TMT bar duly embedded in RCC cover in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil complete all as shown in electrical plase No.3 of SSR Part-I and as specified including earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers of charcoal dust, common salt complete and earth lead connected to earthing test point/main board all as specified and testing of earthing complete all as specified & directed. |
| 78 | Supply and fixing in replacement of burnt conventional fans with BLDC ceiling fans, 5 star rated by Bureau of energy with service value of not less than 6.00, (30W±10%) with remote, with rated speed 350 Rev per min, air delivery 220 Cum/min complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply complete all as specified and directed. Note : Old unserviceable ceiling fan shall be deposited in AGE E/M store yard. |
| 79 | Supply and fixing in repair factory made sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 240 volts double door with isolated neutral bar and shrounded bus bar IP protection 43 IK-09 protection having door earthing complete all as specified and directed. |
| 80 | Supply and fixing in repair125 Amp 4 Pole MCB isolator, 415 Volts with breaking capacity 36 KA complete all as specified and directed. A Please Enable Macros to View BoQ information |