| 1 | Dismantling plain or corrugated sheeting, any gauge, thickness complete all as specified and as directed. |
| 2 | Dismantling of timber in scantling 40 sq cm and over in section in any position in unframed work complete all as specified and as directed. |
| 3 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm allcomplete all as specified and as directed. |
| 4 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area n.exc 1.5 sqm complete all as specified and as directed. |
| 5 | Dismantling of wall and ceiling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and as directed. |
| 6 | Demolition cement concrete (un reinforement) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 7 | Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc complete all as specified and as directed. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. etc complete all as specified and as directed. |
| 9 | M&L for mild steel rolled sections conforming to Fe - 290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafter and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including truss etc complete all as specified and as directed. |
| 10 | M&L for preparation of new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide complete all as specified and as directed. |
| 11 | Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and as directed. |
| 12 | Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in as ridge,eaves,facia,valley ,gutter fixed with self tapping screws as in roof complete all as specified and as directed. |
| 13 | S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed. |
| 14 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sidesb complete all as specified and as directed. |
| 15 | S&F Mild steel butt hinges 100mm long, medium weight, cold rolled. complete all as specified and as directed. |
| 16 | S&F 250 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium complete all as specified and as directed. |
| 17 | S&F Extruded aluminium alloy handles 150mm long, fabricated type, anodised. complete all as specified and as directed. |
| 18 | S&F Aluminium anodised barrel tower bolts, 150 mm long, of extruded section. complete all as specified and as directed. |
| 19 | M&L for precast block masonry with solid blocks of (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) exe 10 CM width and setting in CM morter (1:6) complete all as specified and as directed. |
| 20 | M&L 15 mm thick rendering plaster on fair faces of conc faces/ brick faces smooth without extra cement in CM (1:4) complete all as specified and as directed. |
| 21 | M&L for rendering 20 mm thick in CM (1:4) in two layers of 10mm each (outer layer CM should be added with WPC) on other than fair faces of brick or concrete surfaces, finished even & fair without using extra cement (WPC for finishing layer will be paid seperately as supply only) complete all as specified and as directed. |
| 22 | Supply only liquid integral water proofing compound complete all as specified and as directed. |
| 23 | M&L for 25 mm thick cement concrete (1:2:4), type B-0 (using 12.50 mm graded crushed stone aggr) as in Damp proof course to horizontal or vertical surfaces including necessary formwork etccomplete all as specified and as directed. |
| 24 | M&L for preparation of new plaster surfaces and applying priming plastered and other surfaces with alkali resistance pimimg paint and aplying two coats of acrylic oil emulsion distemper on walls complete all as specified and as directed. |
| 25 | M&L Preparation of newly plastered surfaces of walls and applying two coats of cement paint over a coat of suitable primer on new surfaces of walls complete all as specified and as directed. |
| 26 | M&L for 40 mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in floor complete all as specified and as directed. |
| 27 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 20mm graded crushed stone aggregate) as in floor complete all as specified and as directed. |
| 28 | M&L for 6 mm thick plywood, 5 ply, grade BWR type BB fixed with self screws to timber frame work in Wall/Ceiling complete all as specified and as directed. |
| 29 | M&L for Synthetic enamel paint (1st grade in quality) (Two coat ) on Surfaces of any description, not otherwise descri-bed, over 10cm width or girt and complete all as specified and as directed. |
| 30 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded completed all as specified and as directed. |
| 31 | S&F 3mm thick, sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed. |
| 32 | M&L for RCC M-25 (Design Mix) using 20mm graded stone aggr as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 33 | M&L for formwork to sides of concrete foundations,plinth beams for rough finished surface of concrete, complete all as specified and as directed. |
| 34 | M&L for RCC M-25 (Design mix) using 20mm graded stone aggr as in Beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 35 | M&L for formwork to sides and soffits for rough finished of floors or roof beams, lintels cantilevers, shelves including supports etc complete all as specified and as directed. |
| 36 | Use & waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed. |
| 37 | M&L for TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as in reinforcement of drain cover slab complete all as specified and directed. |
| 38 | All as per item No 37.00 here-in-before but 5mm dia and over upto and including 10 mm dia as in stirrup, spacer and binders complete all as specified and directed.. |
| 39 | M&L for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection; path / hardstanding etc laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and fairs complete all as specified and as directed. |
| 40 | M&L for PCC (1:3:6 ) type C-2 (using 40mm graded crushed stone agg) as in surface channel / drains complete all as specified and as directed. |
| 41 | Extra forming fair finished drain or channel 30 cm inner girth cement concrete using extra cement including forms moulds mitred and stopped ends etc complete all as specified and as directed. |
| 42 | M&L for Cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggr.) as in foundations, filling and mass concrete and complete all as specified and as directed. |
| 43 | M&L walling of RR stone masonry uncoursed, well bonded, bedded and solidly hearted built in CM (1:6) incl brought upto course at interval of every 60cm complete all as specified and as directed. |
| 44 | Dismantling wall tiling & floor tiles incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as as directed. |
| 45 | Demolition of brickwork or stone/boulder masonary built in cement mortar including all quoins, arches, pillars, precast PCC bond stones including separating serviceable stones/boulders & setting aside for reuse in the work and removal of unserviceable materials from site complete all as as directed. |
| 46 | M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in sub-base complete all as specified and as directed. |
| 47 | M&L for 25mm thick Cement concrete (1:2:4), type B1 (using 20mm graded crushed stone aggregate) as in base complete all as specified and as directed. |
| 48 | M&L non skid ceramic colured tiles 7 to 8mm thick, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm, in floors etc. set & jointed in neat cement slurry & pointd in coloured cement to match in floor over & incl 15mm th screed bed in CM (1:6) complete all as specified and as directed. |
| 49 | M&L for Glazed ceramic tiles in vertical surface 300x250x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match & incl 10mm th screed bed in CM (1:4) complete all as specified and as directed. |
| 50 | S&F 4mm thick (E-Boards) Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified and as directed. |
| 51 | S&F for Anodised aliminium snap grid frame work for false ceiling confirming IS:733, 737 & IS:1285 complete all as specified and as directed. |
| 52 | M&L for RCC (Nominal mix) (1:2:4), type B1 (using 20mm graded crushed stone aggr) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 53 | M&L for RCC (Nominal mix) (1:2:4), type B1 (using 20mm graded crushed stone aggr) as in beams, cantilevers, lintel over 1.5 m span complete all as specified and as directed. |
| 54 | M&L for formwork to sides and soffits for rough finished of floors or roof beams, lintels cantilevers, shelves including supports etc complete all as specified and as directed. |
| 55 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 56 | Only Fixing of Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating complete all as specified and as directed. |
| 57 | Re-fixing of Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed. |
| 58 | Taking down carefully copper / aluminium point wiring(light,fan,socket or power) complete along with fittings such as switches ,Sockets, ceiling rose , lamp holder ,tube light fittings and making good distrubed surfaces on walls etc. complete all as specified and as directed. |
| 59 | M&L for point wiring with 1.5 Sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) Cable of working voltage 1100 Volts grade conforming to IS-694 pt-I & II of 2000 drawn in and including 25 mm size PVC rigid non matellic casing caping (Double lock) with all casing capping fittings & accessories with PVC Box backelite sheet fixed with brass screws & cup washers including 1.5 sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) cable as earth continuity conductor connected to main switch / DB's or common earth dolly complete for for light point/ fan point/ exhaust fan point/ call bell point/ controlled by one switch 5/6 Amp one way complete all as specified and as directed. |
| 60 | All as per item No.59.00 here-in-before but for one socket outlet/metal clad socket of 5 Amps fixed on independent board with 1.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 1.5 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and as directed. |
| 61 | All as per item No.59.00 here-in-before but for one socket outlet/metal clad socket of 15 Amps fixed on independent board with 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and as directed. |
| 62 | S&F switch piano, flush type, 5 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and as directed. |
| 63 | S&F Switch socket combination, 2 and 3 pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as specified and as directed. |
| 64 | S&F Switch socket combination, 2 in 1, 6 pin, 5/6 Amps and 15/16 Amps, multipurpose , flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as specified and as directed. |
| 65 | S&F Ceiling rose, PVC/polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and as directed. |
| 66 | S&F in sheet metal enclosure for 8 way Distribution Boards (DB’s), single pole and neutral double door with IP-43 protection suitable for fixing MCB's/lsolators complete all as specified and as directed. |
| 67 | S&F MCB single pole & neutral 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as specified and as directed. |
| 68 | S&F MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as specified and as directed. |
| 69 | S&F Lamp holder angular/straight insulated body, with back plate suitable for batten fittings, white/ivory finish complete all as specified and as directed. |
| 70 | S&F in replacement LED retrofit lamp B22 holder base with polycarbonate body and aluminium heat sink of 09/10W complete all as specified and as directed. |
| 71 | S&F LED light fitting 1 x 18 W (4 FT), CRI >=80, CT >=5700K, wall / surface mounted, integrated type, constructed of fire retardant engineering grade extruded plastic & decorative end caps with integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with suitable fixing arrangements complete including 01 No 18 W (4 FT) LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 72 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'Medium grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print complete all as specified and as directed. |
| 73 | Supply, Laying, jointing & testing in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs and testing. XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade of cross sectional area of 16 Sqmm 4 core complete all as specified and as directed. |
| 74 | Excavation in trenches not exc 1.5m wide and n. exc 1.5M deep for fdn / trenches and getting out for soft / loose soil complete all as specified and as directed. |
| 75 | Removing excavated material n exc 50m and depositing at a level n.exc 1.5M above ground complete all as specified and as directed. |
| 76 | Returning/filling in layers, spreading leveling, watering and well ramming in layers n.exc 25m in sof/loose soil complete all as specified and as directed. |
| 77 | Supply and laying of DWC pipe,ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket,bend,couplers etc confirming to IS 14930,part-II complete with fitting cutting,jointing etc of size 40 mm outer dia complete all as specified and as directed. |
| 78 | S&F water proof 10 watt LED bulk head 1x10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable fo suitable size complete all as specified and as directed. |
| 79 | S&F bore 40 mm pipe galvanized iron medium grade complete with all fittings fixing on wall, jointed tested and commissioned complete all as specified and as directed. |
| 80 | S&F in replacement angle holder for LED bulb of any type including bulb complete all as specified and as directed. |
| 81 | S&F for PVC rectangular block for mounting, switches, sockets, fan regurators etc with 3 mm thick plastic laminated sheet cover of size 100mmX100mm and 50 mm deep, complete all as specified and as directed. |
| 82 | S&F aesthetically designed 2X2 LED flat panel for ceiling mounting which provides soft light and glare free illumination not less than 36 watt,efficiency >125 lm/ W, including and connecting up complete all as specified and as directed. |
| 83 | All as per item No. 59.00 above but, one socket outlet, three pin, 5/6 Amp on the same board with other switches complete all as specified and as directed. |
| 84 | S&F for PVC rectangular block for mounting, switches, sockets, fan regurators etc with 3 mm thick plastic laminated sheet cover of size 200mmX150mm and 50 mm deep, complete all as specified and as directed. |
| 85 | S&F in sheet metal enclosure for 4 way Distribution Boards (DB’s), tripple pole and neutral double door with IP-43 protection suitable for fixing MCB's/lsolators complete all as specified and as directed. |
| 86 | M&L for sub main wiring with 2 runs of 6 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLS grade with drawn in surface PVC casing-caping width not less than 25mm dia and one run of PVC insulated serviceable of 6 sqmm as earth continuity conductor drawn in casing and capping with accessories complete including taking down old unservicaeble wiring.NOTE: 3 runs of 6 Sqmm wire and 1 run of conduit will be measured as one unit i.e RM |
| 87 | S&F for MCB tripple pole & neutral 63 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as specified and as directed. |
| 88 | S&F for MCB single pole & neutral 40 to 63 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as specified and as directed. |
| 89 | S&F in replacement LED light of 70W, CAVELO, with integrated well glass, 120 Im/W with IP 66 as standard connecting up with three core flexible copper conductor cable fo suitable size complete all as specified and as directed. |
| 90 | S&F for bore 40 mm pipe galvanized iron medium grade complete with all fittings fixing on wall, jointed tested and commissioned complete all as specified and as directed. Please Enable Macros to View BoQ information |