Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for preparation of old decorated wall surfaces plastered or unplastered, by brooming down or steel wire brushing, scrapping down moulds, moss and efflorescent salts and trading oil & greasy spots, including cornices etc and applying one coat of white wash on wall, complete all as specified and directed. |
| 2 | M&L for preparation of old decorated ceiling surfaces including cornices pilasters by brooming down or steel wire brushing, scraping down,smoke shoot,moulds,moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on ceiling, complete all as specified and directed. |
| 3 | M&L for preparation of old decorated wall surfaces plastered or unplastered, including cornices pilasters by brooming down or steel wire brushing and efforescent salts and applying one coat of distemper oil emulsion on wall, complete all as specified and directed. |
| 4 | M&L for preparation of old decorated wall surfaces, including crack filling by compound of putty to get a uniform smooth surfaces including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying one coat of plastic emulsion on wall, complete complete all as specified and directed. |
| 5 | M&L for preparation of old surfaces of wall by brooming down or steel wire brushing, scrapping down mass and efflorescent salts and trading oil & greasy spots, washing rubbing down and stopping distempered surfaces and applying two coat of exterior acrylic emulsion on wall as per the manufacturer’s instruction over and including 2mm thick complete all as specified and directed. |
| 6 | M&L for preparation of old decorated surfaces plastered or unplastered on wall and applying one coat of cement base paint as approved coloured and shade by GE, complete all as specified and directed.Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 7 | All as per item No. 6.00 here-in-above, but applying two coats of cement base paint. |
| 8 | M&L for preparation of old decorated surfaces plastered or unplastered on wall and applying 2 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and also M&L for applying two coats of plastic emulision paint on wall surfaces as per manufacturer’s instruction, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.ii)- Plastic paint shall be in one or more colours/ shades all as approved by GE. |
| 9 | All as per item No. 8.00 here-in-above, but applying two coats of oil bound distemper. |
| 10 | M&L for preparation of old painted wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and as directed . |
| 11 | All as per item No. 10.00 here-in-above, but steel surfaces. |
| 12 | Taking down carefully cement plaster/ spalled out concret from wall, ceiling of RCC slab, sunshedes, beams, etc by chipping out lightly including necessary scaffoding etc., complete all as specified and directed. |
| 13 | M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement, complete all as specified and as directed. |
| 14 | M&L for 10 mm thick Rendering in CM 1:4 on fair faces of brick work or conc surfaces as in ceilings/chajja/facia & finished even & smooth w/o using extra cement, complete all as specified and as directed. |
| 15 | M&L for preparation of new plastered wall surfaces and applying 2 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and also M&L for applying two coats of oil bound distemper on wall surfaces, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.ii)- OBD shall be in one or more colours/ shades all as approved by GE. |
| 16 | M&L for Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling surfaces complete all as specified and as directed. |
| 17 | Dismantling, stone slab, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed. |
| 18 | M&L non skid ceramic colour joint free tiles 6 to 7 mm thick of size area exc 0.06Sqm but nexc 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match including M&L for 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 19 | M&L for glazed coloured ceremic tiles in vertical surfaces as in skirting, dado & etc., size 300x200x7mm/ 300x450mmx7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including M&L for 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 20 | M&L Virified Cermic tiles light shed as existing 10 mm thick (squre/retangular) polished, area of each tiles n ecceding 0.36 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or colured cement including M&L for 15 mm thick screed bed in CM 1:6 to match complete all as spcified and directed. |
| 21 | All as per item No. 20.00 here-in-above but skirting surface inluding M&L for 10 mm rendering in Cm 1:4 complete all as specified and directed. |
| 22 | Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area not exc 1.5 Sqm each, complete all as directed. |
| 23 | Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed. |
| 24 | Taking down shutters of any description area exceeding 1.0 Sqm but not exceeding 2 Sqm each complete all as specified and as directed. |
| 25 | M&L mild steel work as in door frame, coolar stand and similar work fixed with angle cleates, confirming to Fe 410 Grade E - 250 Quality A, complete all as specified and as directed. |
| 26 | M&L for 35mm thick factory made 2nd class hard wood glazed and skelton shutter and open rebated and prepared to receive glass, gauge etc (without sash bars), edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I Section 8 Clause 8.24 (a) complete all as specified and directed. |
| 27 | S&F 35 mm thick factory made second class hard wood plain framed panelled shutter (Two panel) with lock rail and pannel of 9 mm thicks BWP commercial ply or 12mm veneered particle board with commercial veneered on both faces the size of rails and style as per IS-1003 (Part-I) kiln seasond and chemicadly pressue treated all as specified and directed. |
| 28 | S&F of factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made of MS tubes for top & bottom rail. MS frame shall be covered with heat moulded plain color pvc ‘C’ channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted to the MS Frame/sealed to the stiles & rails with suitable PVC sheet beading, and joined 30mm thick (style) consisting of frame made of MS tubes for top & bottom rail. MS frame shall be covered with heat moulded plain color pvc ‘C’ channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color pvc sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail paneling of plain colour PVC sheet to be fitted the MS Frame/sealed to the stiles & rail with suitable PVC sheet beading, and joined together with solvent cement, all as specified. |
| 29 | M&L for solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified. |
| 30 | M&L pre powder coated coloured aluminum anodized door frame and shutters for door/windows, etc or as approved by GE including jointing cleats for fixing etc as per manufacturers instructions complete all as directed. Note : (i) Weight of all aluminum members shall be measured(ii) Hinges, handles etc shall be measured and paid separately. (iii) Glass pan and rubber beading shall be measured and paid separately. (iv) Fixing of shutters with fittings shall be as per manufacturers instructions. |
| 31 | S&F Pre powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.), complete all as specified and as directed. |
| 32 | S&F standard powder coated coloured aluminum anodized Deco grill ‘U’ channel 25x12 mm with and including perforated aluminum wire mesh weight not less than 550gm/Sqm over grill complete all as specified and directed . |
| 33 | M&L for 4.8 mm thick tinted/frosted glass fixed with alu channel/snap grid and rubber beading packing in door, windows and ventilator and securing complete all as specified and directed . |
| 34 | S&F stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.00 mm complete all as specified and directed. |
| 35 | S&F in repairs hydraulic door closer designation No 3 universal type suitable for door shutter 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium (die cast) body complete all as specified and directed. |
| 36 | Taking down steel window/ventilator complete all as directed. |
| 37 | S&F of aluminium anodized ,tower bolt 200 mm long, extruded section complete all as specified and directed. |
| 38 | S&F aluminium anodised handle extruded section of size 150mm long complete all as specified and directed. |
| 39 | S&F of aluminium alloy anodised sliding door bolt woth hasp and stalpe (bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long complete all as specified and directed. |
| 40 | S&F of mild steel butt hinges 100 mm size complete all as specified and directed. |
| 41 | S&F 100mm size single action door spring hinge complete all as specified and directed. |
| 42 | S&F floor door stopper of alluminium alloy body and toungue anodised with hard drawn steel spring 140mm long complete all as specified and directed. |
| 43 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame incld punching or drilling out old glazing pins/ spring clips and provding and fixing new ones, complete all as specified and as directed. |
| 44 | S&F for 3 mm thick figurred, pin headed glass ordinary quality & glazing with oil putty in square n exc 0.50sqm ineach pane, complete all as specified and as directed. |
| 45 | S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed. |
| 46 | S&F in repair galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.00 mm complete all as specified and directed. |
| 47 | S&F in replacement decorative type curtain rod stainless steel finish of pipe 22 to 25mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end, complete all as specified and as directed. |
| 48 | M&L for high quality looking mirror 5 mm thick with fancy type beading fixed to wall with chromium plated screw area n exc 2.0 sqm fixed in repairs complete all as specified and as directed |
| 49 | S&F in repairs of stainless steel sinks with drainage boards ISI marks of 01 mm thick size 1040 x 510 mm bowl size 510 x 404 x 200 mm including waste coupling waste pipe brackets made high grade AISI-304 stainless steel, complete all as specified and as directed |
| 50 | S&F in replacement white vitreous china squatting pan \\"Orissa pattern\\" of size 580 mm X 440 mm with integral foot rests and PVC 'P' or 'S' trap, including M&L brackets, flush HDPE pipe of 32 mm dia and PVC connection 15mm size, 450 mm long with PTMT nuts & fixing arrangement of cistern, including provision of cement concrete bedding 1:5:10 type E2 complete all as specified and as directed. |
| 51 | S&F in replacement vitreous ware wash down water closet [Pedestal Pattern], white [ETWC] including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap connecting to drain pipe and flushing pipe etc., complete all as specified and directed. |
| 52 | S&F in repair single piece EWC with slim soft close seat cover complete set constellation dual flush (WB consetellation 5 ped constellation, EWC, cistern & lid CON dual flush, seat cover constellation, cistern fitting (water saver- duel flush) etc complete all as specified and directed. |
| 53 | S&F in replacement vitreous china ware wash hand basin, white, flat back of size 400 mm X 550 mm including 32 mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe,PVC connection15mm size with PTMT nuts of length 300mm long complete all as specified and as directed. |
| 54 | S&F in repair Bidet spray (Health faucet) with 1.5 meter CP tube and holder, complete all as specified and directed. |
| 55 | S&F in repair 15 mm bore CP brass two way angular stop cock, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe complete all as specified and directed. |
| 56 | S&F in repair 15 mm bore CP brass angular stop cock, screwed down high pressure with crutch or butterfly handle scrwed both ends for iorn pipe, complete all as specified and directed. |
| 57 | S&F in replacement of bib cock with flange 15mm dia, chromium plated, brass, fancy type, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 58 | S&F 15mm bore CP brass, central hole basin mixture pop um waste system with 450 mm long copper pipe and brass nuts ISI Marked sitable for over head counter, complete all as specified and directed. |
| 59 | S&F CP Wall mixture 3-in-1 system includinjg 1.50 mtr long tele showeer and overhead shower of size 150mmx150mm Make Jaquar incl hand shower, complete all as specified and directed. |
| 60 | S&F in repair of chromium plated shower rose 125/150mm dia round/square shape complete all as specified and directed. |
| 61 | Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 110mm bore as directed |
| 62 | Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 75mm bore as directed |
| 63 | Supply & laying 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches of suitable size complete all as specified and as directed . |
| 64 | Supply & laying 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches of suitable size complete all as specified and as directed . |
| 65 | S&F 75 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and as directed. |
| 66 | S&F 110 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and directed. |
| 67 | S&F 75mm bore PVC [SWR] branch piece, single (single Y) equal or unequal complete all as specified and as directed. |
| 68 | S&F 110mm bore PVC [SWR] branch piece, single (single Y) equal or unequal complete all as specified and as directed. |
| 69 | S&F 75mm bore PVC [SWR] floor trap with grating including jointing with solvent cement complete all as specified and as directed. |
| 70 | S&F in replacement 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia complete all as specified and as directed. |
| 71 | S&F in replacement 500 ltrs capacity rotational moulded polythene water storage tank white colour, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I, complete all as specified and directed. |
| 72 | All as per item No.70.00 here-in-above, but capacity of tank 1000 ltr. |
| 73 | S&F 20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 74 | M&L 18 to 20 mm thick granite(approved quality by user ) in WHB counter top etc laid in dry bedded in pinning to wall including cutting rubbing grinding and polishing to edges and rounding off granite polish slab for smooth finish complete all as specified and directed. |
| 75 | S&F in repair corner glass shelf 250 mm size complete all as specified and directed. |
| 76 | S&F in repair glass shelf below WHB 300 mm size complete all as specified and directed. |
| 77 | S&F in repair toilet paper holder chromium plated complete all as specified and directed. |
| 78 | S&F in repair stainless steel kitchen plate rack of size 1000 mm x 1200 mm x 300 mm made out of 1 mm thick stainless steel sheet complete all as specified and directed.. |
| 79 | S&F in repair plastic water closet seat white closed pattern with flat bottom and cover and aluminium hinging device complete all as specified and directed. |
| 80 | S&F in repair CP towel ring 20 mm dia fancy type as per sample approved by Engr in charge complete all as specified and directed. |
| 81 | Taking out from position framed wood work as in cupboards/cabinets etc with all fittings ,shutters, shelves, drawers etc in any position fixed in walls or floors & removal of the rubbish outside MD land all as directed at site for overall sizes exc 0.50 sqm but not exc 1.50 sqm & depth not exc 60cm, complete all as specified and directed. |
| 82 | M&L for UPVC Coated Celuka printed in one of two different colours( with wood grain printed pattern /ivory clour finish) polyvinyl chloride (PVC) sheet frame of width 150mm & 18mm thickness made out of extruded 18mm PVC sheet and joined with suitable Cement Solvent adhesive and screw.The frame shall be fixed to the wall using 75mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 3 Nos. of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member etc, all as per manufracturers specifications, complete all as specified and as directed. |
| 83 | M&L for 18 mm thick solid PVC sheet UPVC Coated Celuka printed in one of two different colours( with wood grain printed pattern /ivory clour finish) as in kitchen cabinet shutters ,all round body of cabinets , shelves ,drawers etc cut to required size jointed with solvent cement & steel screws etc complete all as specified & directed . |
| 84 | S&F '0' degree clip type self closing hinges for cabinets fixed with cadimum coated screws, complete all as specified and as directed. |
| 85 | S&F 100mm size bright finished chromium plated steel handle of approved shape & design fixed with cadmium coated screws on the kitchen cabint shutters, complete all as specified and as directed. |
| 86 | S&F drawer runners folding type with guide channels & sliding channel with approipiate ball bearing/ rollers etc complete to obtain smooth movement of the drawers,complete all as specified and directed. |
| 87 | M&L for stainless steel tray as per trade pattern of various sizes for drawer to keep the kitchen utensil, complete all as specified and as directed. |
| 88 | M&L for Providing and injecting ATT chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc., complete all as specified and as directed. |
| 89 | M&L for Providing and injecting ATT chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and as directed. |
| 90 | Taking up or down 20mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and directed. |
| 91 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and directed. |
| 92 | Supply, laying, testing & commissioning of 20 mm outer dia CPVC pipe,SDR-11, with all fitting (eblow, socket,tee with internal thread of brass) fixed to wall, ceiling or laid on floor, with CPVC solvent, complete all as specified and directed. |
| 93 | Supply, laying, testing & commissioning of 25 mm outer dia CPVC pipe,SDR-11, with all fitting (eblow, socket,tee with internal thread of brass) fixed to wall, ceiling or laid on floor, with CPVC solvent, complete all as specified and directed. |
| 94 | Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. |
| 95 | M&L for (concealed) point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC concealed (including Cutting Chases and make good the distrubed surfaces as per existing finishes) conduit of size 20 mm or med grade as required as site, totally concealed in walls / and surface on floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, suitable for One light/fan/bell point controlled by one, one way switch, complete all as specified and directed.Note:- The rates of chase cutting on wall done concealed conduit & making good good the distrubed surfaces as per existing finishes and steel terminal boxes are included in the unit rates |
| 96 | All as per Sr. item No. 94.00 here-in-above, but suitable for One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch. |
| 97 | All as per Sr. item No. 94.00 here-in-above, but suitable for One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch. |
| 98 | All as per Sr. item No. 94.00 here-in-above, but one light point controlled by two, two-way switches. |
| 99 | All as per Sr. item No. 94.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable (FRLS)including 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 5 pin 15 Amp socket outlet on independent board . |
| 100 | M&L for Point wiring (Modular Concealed) using approved colour coding as per IS Red/Yellow/Blue, Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LS cable 1100 Volts grade ISI 694 marked with valid CML No. in and including medium grade PVC concealed conduit (including Cutting Chases and make good the distrubed surfaces as per existing finishes) of dia not less than 20mm and conduit accessories ISI marked with valid CML No. ( IS 9537 -1983 for wall/roof /floor etc with pressed flush metal boxes covered with inner plates & outer plates etc suitable for mounting of Modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continully conductor to commonearth and connecting to earrth dolly suitable for One light/fan/bell point controlled by one, one way switch, complete all as specified and directed.Note:- The rates of chase cutting on wall done concealed conduit & making good good the distrubed surfaces as per existing finishes and steel terminal boxes are included in the unit rates |
| 101 | All as per Sr. item No. 99.00 here-in-above, but suitable for One socket outlet 3 pin 6 Amps on same board |
| 102 | All as per Sr. item No. 99.00 here-in-above, but suitable for One socket outlet 3 pin 6 Amp on independent board |
| 103 | All as per Sr. item No. 99.00 here-in-above, but suitable for One light point controlled by two, two-way switches |
| 104 | All as per Sr. item No. 99.00 here-in-above, but with using 2.5 Sq mm single core multistanded copper conductor cable (FRLS)and 2.5 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board . |
| 105 | S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 Volts complete all as specified and as directed. |
| 106 | S&F switch piano, flush type, single pole, two way, 5/6 Amps, 230 Volts complete all as specified and as directed. |
| 107 | S&F switch piano, flush type, single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed. |
| 108 | S&F bell push, 5/6 Amps, 230 Volts complete all as specified and as directed. |
| 109 | S&F socket out let flush type 6 amp 3/5 pin suitable for 6 Amp plug top 230 V complete all as specified & directed. |
| 110 | S&F socket out let flush type 3/6 pin suitable for 16 Amp plug top multipurpose 230 V, complete all as specified & directed. |
| 111 | Supply and fix bell AC ing dong type 230 volts, complete all as specified & directed. |
| 112 | Supply and fix fan regulator electronic switch/ socket type complete all as specified and directed. |
| 113 | S&F lamp holder insulated body with back plate batten/angle type for batten fittings incl taking down old unserviceable holder complete all as specified and directed. |
| 114 | Supply and fix in replacement fan capacitor 2.5 m.f.d for ceiling Fan, incl taking down old unserveable capacitor all as specified and directed. |
| 115 | Supply and fixing in replacement ceiling rose 3 terminals complete incl taking down all as specified and directed. |
| 116 | Supply and fix Modular switch any type and make 6 amp one way 230 V incl dismantling of old unserviceable switch of any make all as specified & directed . |
| 117 | Supply and fixing in replacement Modular switch any type and make 16 amp one way 230 V incl dismantling of old unserviceable switch of any make all as specified & directed . |
| 118 | Supply and fixing in replacement Modular socket Any Type and make, 6 amp 3 Pin one way 230 V all as specified & directed . |
| 119 | Supply and fixing repair Modular socket Any Type and make, 16 amp 5 Pin one way 230 V incl dismantling of old unserviceable switch of any make all as specified & directed . |
| 120 | Supply and fixing Modular switch any type and make 6 amp two way 230 V dismantling of old unserviceable switch of any make all as specified & directed . |
| 121 | Supply and fixing Modular fan Regulator step type and make, 100 watt , 230 Volts ismentling of old unserviceable regulator all as specified & directed . |
| 122 | Supply and fixing Modular Bell push any type and make 6 amp one way 230 V taking down old UNSV bell push all as specified & directed . |
| 123 | S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 10 MCB SP as out going SPN 8 way complete incl dismantling of unservceable DB, complete all as specified & directed. |
| 124 | S&F replacement sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for one No 63 to 100 Amp 10 KA TPN MCCB as incoming complete incl dismantling of unservceable DB, complete all as specified & directed. |
| 125 | Supply and Fix in replacement MCB Single pole\\"B\\" series 5-32 Amps ISI marked incl dismantaling old unserviceable MCB SP, complete all as specified & directed. |
| 126 | Supply and Fix in replacement MCB Single pole & neutral \\"B\\" series upto 63. Amps ISI marked incl dismantaling old unserviceable MCB SPN, complete all as specified & directed. |
| 127 | Supply and fixing in replacement MCB TPN B Curve 63 to 100 Amps Make incl disntaling of old unserviceable TPN MCB, complete all as specified & directed. |
| 128 | Supply and fix in replacement 2-Watt LED Wall Light (bed light) for reading incl taking down old UNSV light , complete all as specified & directed. |
| 129 | Supply and fixing PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 1.5 sqmm as in replacement of any defective/burnt circuit incl taking down old UNSV cable, complete all as specified & directed. |
| 130 | S&F Street light bracket made out of medium grade GI Pipe, bent to shape including GI Clamps nut,bolts washers,reducer of required size for suitable any type fittings etc complete including necessary painting and taking down old UNSV GI Bracket, complete all as specified & directed. |
| 131 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.60 mtr long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm pvc insulated cable, complete all as specified & directed. |
| 132 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt cool white/ warm white 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 133 | Supply and fixing replacement LED lights fitting 1x 20W, 220V, Cool White, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified & directed. |
| 134 | Supply and fixing in replcement LED lights fitting 1x 20W, 220V, Warm White, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified & directed. |
| 135 | S&F in replacement Decorative wall light fixture made up of Polycarbonate/ Acrylic/ Iron/Warm White, suitable for & including 9 W LED Bulb, complete all as specified & directed. |
| 136 | S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified & directed. |
| 137 | M&L in repairs sub main wiring with PVC insulated and unsheathed 2x 6 Sq mm single core multistrandred copper conductor cable(FRLS) passing through in and including PVC conduit , concealing in walls (by means of chasing including making good existing surface and matching existing surface ) ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 6 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire, including taking down old UNSV submain wiring complete all as directed Note :- Two runs of cable 6 Sqmm (FRLS) and One run of 6 Sqmm copper conductor(FRLS) along with conduit shall be measured as one unit length. |
| 138 | M&L in replacement Earthing complete with galvanised steel earth plate electrode 60 x x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal/hard/dense ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion .Note : Rates are deemed to be included for necessary earth work , earth pit with RCC cover of size 300X300 x25 mm etc complete |
| 139 | M&L in repairs sub main wiring with PVC insulated and unsheathed 2x 4 Sq mm single core multistrandred copper conductor cable(FRLS) passing through in and including PVC conduit , concealing in walls (by means of chasing including making good existing surface and matching existing surface ) ISI marked and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 4 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire. Note :- Two runs of cable 4 Sqmm (FRLS) and One run of 4 Sqmm copper conductor(FRLS) along with conduit shall be measured as one unit length including taking down old UNSV submain wiring complete all as directed |
| 140 | Note:- (i) All items in BOQ are for \\"Materials and labour / Supply and fix\\" and to be executed in \\"Repairs/Replacement unless otherwise specifically mentioned as \\"Supply only\\" or Fixing only\\" in BOQ Bidders are required to quote their rates accordingly.(ii) The contract sum shall be arrived at after duducting amount of schedule of \\"Credit\\" from the Total quoted amount(iii) Makes of materials will be approved by GE in writing before commencement of work. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail