| 1 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified & directed, including dismantling of existing asbestos cement corrugated, semi-corrugated, etc. roof coverings , complete all specified and directed. |
| 2 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,fixed with self tapping screws, including dismantling of existing asbestos cement ridge, complete all specified and directed. |
| 3 | M&L for structural steel work in roof trusses (framed), trussed, purlins, crane gantries, rails, water cooler stands, staging for water tanks, grills, gratings, fastenings, etc. and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W (Grade E-250) quality A,,including dismantling of existing steel ,complete all specified and directed. |
| 4 | M&L for Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 30.0cm long, not exceeding 20mm dia of neck, complete all as specified and as directed. |
| 5 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 6 | M&L for rendering 15 mm thick in cement mortar 1:6 on any surfaces of brick work, finished even & smooth without using extra cement, complete all specified and directed. |
| 7 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement,complete all specified and directed. |
| 8 | M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement based paint over a coat of primer , complete all as specified and as directed. |
| 9 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground posts embedded in concrete. |
| 10 | S&F for mild steel works as in fencing posts and struts including cutting tops to bottom shape as directed, drilling holes notching for wire etc flat iron fillets for securing razor wire etc incl all drilling bolting riveting etc and similar works conforming to Fe -290 gde E-165, complete all as specifed and as directed by Enginner-in-Charge. |
| 11 | M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 12 | M&L for plain cement concrete M-15 (1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in copings, kneelers, plinth courses, apex stones, bed plates, kerbs, mud stops, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge. |
| 13 | S&F in repair galvanised, 2-strand, steel barbed wire 2.24mm dia barbed with 2.0 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and as directed by Engineer-In-Charge |
| 14 | S&F for fixing mild steel galvanised concertina coil fencing with punched tape concertina coil 610 mm dia, 10 metre openable length (total length 142 mtrs), having 50 Nos. rounds per 6.0 metre length, spring core wire (2.5 mm dia galvanised wire) of high tensile strength not less than 400-450 gm/ Sqmm with tape (0.52mm thick) and weight 2.0 Kg/metre and fixing the same with existing Y-shaped angle iron placed 2.0mtrs apart and with 6 horizontal R.B.T. (Reinforced Barbed Tape) wire, stud tied with G.I. staple sand, 125 to 127 Nos. of G.I. clips in one coil, to retain horizontal, including necessary nuts and bolts, including taking down existing rusted/damaged concertina coil complete all as specified and as directed by Engineer-In-Charge. |
| 15 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level, complete all as specified and directed. |
| 16 | M&L for plain cement concrete type B-1 1:2:4 using 20mm graded crushed stone aggregate, 25mm thick as in flooring etc. finished the surface even and fair, complete all as specified and as directed. |
| 17 | M&L for non-skid ceramic coloured designer pattern tiles 300x300mmx7 to 8mm thick as in floors etc.set jointed in neat cement slurry and pointed in white cement or coloured cement to match etc, including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, including dismantling of existing floor hearth or wall tiling with cement mortar bedding but not backing and removing, complete all as specified and directed. |
| 18 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces including 15mm thick screed bed/bedding layers in cement and sand mortar 1:6, including dismantling of existing floor hearth or wall tilingcomplete all as specified and directed. |
| 19 | M&L for non skid ceramic tiles 7-8mm thick (square /rectangular) polished, area of each tile not exceeding 0.36 sqm as in skirting etc, set and jointed in neat cement slurry and pointed in white/coloured cement to match in light shade including 10mm thick rendering in cement and sand mortar 1:4 finished the surface even and rough, including dismantling of existing floor hearth or wall tiling complete all as specified and directed. |
| 20 | M&L for 75mm thick, plain cement concrete M-10 1:3:6, type C-1 (using 20mm graded crushed stone aggregate), as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all specified and directed. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 22 | M&L glazed ceramic tile 450x300x 7-8mm thick (coloured) on vertical surfaces such as skirting/dado etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering (Broomed) in cement and sand mortar 1:4, complete all as specified and directed. |
| 23 | M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and providing granite (of any type) 16-18 mm work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite ,over 20 mm thick screed bed in cement mortar 1:4 including moulding to edges, complete all as specified and as directed. |
| 24 | M&L for repairs to sunken floor/ slab with the following specifications:-(a) M&L for repair demolition of PCC and taking out old brick bat filling and taking down plaster upto skirting level and roughening surfaces of old concrete floor and wall by picking, sweeping clean and washing down with water to remove dust etc. (b) All pipe passing through the wall of sunken floor shall be laid before the water proofing treatment is carried out and one number 50mm dia 500mm long medium grade GI pipe spout with SS wire gauge on inside mouth shall be provided.(c) Rendering on uneven surface with 10mm thick cement mortar 1:4, mixed with IWPC to make it even.(d) All junction of side wall where pipes are passing through shall be sealed with epoxy putty.(e) After cleaning apply three coat of polymer modified cementious water proof coating as per manufacturerer instruction to bottom and vertical sides upto skirting height of the floors, proportion & applications as per manufacturer instruction.(f) The water proofed area shall be tested by filling water for at least 03 days. In case any leakage is noticed water proofing treatment shall be re-done and re-tested.(g) The sunken floor and sides of wall upto skirting height shall be plastered with 15mm thick cement mortar 1:4 mixed with IWPC @ 3% by weight including rounding at corner and junction sloping towards spout. |
| 25 | item No 24 contd.....(h) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 type C-0 all around.(j) The sunken floor shall be filled with PCC 1:5:10 type E-2 (1 cement : 5 coarse sand : 10 graded brick aggregates 40mm nominal size) complete.(k) Base of 25mm thick PCC 1:2:4 type B-0 to receive screed bed and tiles.NOTES:- Rates of below mentioned elements is includinguded in the said item.(i) IWPC included(ii) GI pipe of dia 50mm, 500mm long, stainless steel wire mesh suitable size including this item.(iii) For payment purpose, floor area of sunken shall be measured. |
| 26 | M&L for grubbing up bushes, tree trunks portion not exc 30cm girth including cutting of trees/bushes grown in over wall and roofs digging out roofs and making good disturbed area of walls and roofs with plain cement concrete type C-1, 1:3:6 using 20mm graded crushed stone aggregates and matching to existing descriptions/ specifications, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 27 | M&L for grubbing up bushes, tree trunks portion not exc 30cm girth including cutting of trees/bushes grown in over wall and roofs digging out roofs and making good disturbed area of walls and roofs with plain cement concrete type C-1, 1:3:6 using 20mm graded crushed stone aggregates and matching to existing descriptions/ specifications, complete all as specified and as directed. Please Enable Macros to View BoQ information |