| 1 | Dismentling and removing old cement plaster from brick walls and stacking the useful materials for reuse and removing debris with in 50m lead with cost of all labour with T nad P etc complete as per drawing and Technical specification and as directed by the Engineer-in-Charge |
| 2 | Dismentling and removing old grading plaster from roof slab and stacking the useful materials for reuse and removing debris with in 50m lead with cost of all labour with T nad P etc complete as per drawing and Technical specification and as directed by the Engineer-in-Charge |
| 3 | Dismentling and removing 2.5cm thick A.S Flooring and stacking the useful materials for reuse and removing debris with in 50m lead with cost of all labour with T nad P etc complete as per drawing and Technical specification and as directed by the Engineer-in-Charge |
| 4 | Dismentling and removing old tarfelt from roof slab and stacking the useful materials for reuse and removing debris with in 50m lead with cost of all labour with T nad P etc complete as per drawing and Technical specification and as directed by the Engineer-in-Charge |
| 5 | Providing and laying water proofing with polymeric bitumious membrane or 2.25 kg/sqm and 2mm thickness consisting of layers having centre core of 20 microns thermoplastic high molecular high density polyethylen HMHDPE firm of grade 2504 including priming the surface with bitumenous primer @0.3kg/sqm providing a coat of hot blown bitumen of 1.32 kg/sqm applying and laying plastic felt membrane with 10 cm overlap adchered to blown bitumen of 85/25 ot 90/15 grade etc complete as per drawing and Technical specification and as directed by the Engineer-in-Charge |
| 6 | Earth work in excavation in all kinds of soil or gravelly soil for leveling the area with all leads & lifts, Disposal of excavated earth & unserviceable Mterials by mechanical means with 5 km. Lead and including loading & unloading, hire & running charges of materials etc.with all labour and T&P required for the work complete in all respects. |
| 7 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. In depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only).Ground Floor |
| 8 | Cement concrete of prop.(1:3:6) in foundation and floors up to lowest bed level using hard black granite crusher broken metal of size 40 mm size down graded of approved quality from approved quarry as per approved design including hoisting,lowering,laying compacting concrete in layers not exceeding 6” thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc., complete in all respects including dewatering if required as per direction of Engineer-in-Charge. |
| 9 | Cement concrete of prop.(1:2:4) in foundation and floors up to lowest bed level using hard black granite crusher broken metal of size 12 mm size down graded of approved quality from approved quarry as per approved design including hoisting,lowering,laying compacting concrete in layers not exceeding 6” thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc., complete in all respects including dewatering if required as per direction of Engineer-in-Charge. |
| 10 | Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.Foundation & Plinth |
| 11 | Superstructure |
| 12 | 12mm thick cement plaster (1:6) finished smooth to inside 9''/10'' thick brick walls after raking out the joint including watering, curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect as per direction of Engineer in charge. |
| 13 | Providing 2.5 mm thcik A.S Flooring. CC (1:2:4) using 12mm size HBG Chips of approved quality from quarry etc complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge |
| 14 | Providing and laying Grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge |
| 15 | Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm Vetrified floor tile of matt finish with veilcraft (VC/FT ) shield( Scratch free/stain free) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 16 | Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm Vetrified floor tile of matt finish with veilcraft (VC/FT ) shield( Scratch free/stain free) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 25 mm thick cement mortar (1:1) (1 cement : 1 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 17 | Supplying, fitting & fixing of 8-10 mm thick and size of 600x600 mm vertified wall tile of in dadoes, skirting and risers of steps of laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 18 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD./ Equivelent make) three track Sliding Window duly manufactured using UPVC reinforced profiles of 108 mm x 45 mmx2.5 mm for outer frames, and window Sash of 39x58x2.5 mm Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards.------ (V) etc complete as per direction of Engineer-in-Charge. |
| 19 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD./ Equivelent make) Casement Door with top fixed 60 series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Door Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards.------ (V) etc complete as per direction of Engineer-in-Charge. |
| 20 | Supplying, fitting, fixing of all types of MS Grills made of ISI marked standard MS Angles of approved thickness and quality of approved Manufacturers with all required iron and aluminum fittings, including mending to sizes supplying and fixing hinged cleats, sand blocks and fixing of oxidized iron or chromium plated iron aldrops, tower bolts, knobs or rings or handles, hinges, screws and other fittings, etc. complete as per requirement including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.All Floors |
| 21 | Supplying fitting fixing wire mesh to window with all fittings with batton including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 22 | Supplying, fitting, fixing of all types of MS Angle in proper position made of ISI marked standard MS Angles of approved thickness and quality of approved Manufacturers with all required iron and aluminum fittings, including mending to sizes supplying and fixing hinged cleats, sand blocks and fixing of oxidized iron or chromium plated iron aldrops, tower bolts, knobs or rings or handles, hinges, screws and other fittings, etc. complete as per requirement including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.All Floors |
| 23 | Hoisting position in trusses & purlin joist etc (Labour only) |
| 24 | Supplying fitting fixing of Profile Colour Sheets on roofing with all fittings including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 25 | Painting two coat with Plastic Emulsion Paint over a coat of primer to make in even finished surfaces in all floors and heights to wall surface oa pproved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 26 | Providing two coats with Weather coat paint over a coat of primer on plaster surface of approved shade on new works over a coat of primer to give an even shade including scaffolding to outside walls, including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 27 | Painting two coat with approved Synthetic enamel Paint over the wall surface to make in even finished surfaces in all floors and heights to Iron surface of approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 28 | R.C.C.work of Grade M-20 having a minimum compressive strength in work test of 250kg/Cm2 in 15cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 & IS 516 using 20mm down graded size black crusher broken hard granite stone chips of approved quality & from approved quarry including hoisting, lowering & laying concrete & compacting by using vibrators, watering & curing for 4 (four) weeks centring, shuttering & finishing the exposed surface smooth providing grooves or beads where necessary including cost & conveyance royalties & taxes of all materials & labour required for the work etc., complete in all respect but excluding cost & conveyance of M.S.Rods or tor steel and binding wires of 18 to 20 gauge & labour charges for straightening, cutting, bending etc.,of the HYSD Rods or tor steel & binding wires & laying the grills placing in proper position as per direction of Engineer-in-Charge.Precast Slab |
| 29 | Supplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-500) steel of approved manufacturer as per section 1600 §ion 1900 of MORT&H specification for Road and Bridge works including cost, conveyance and taxes of all materials, binding wires 18 to 20 gauge and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. (weight of reinforcement sall be calculated on the basis of IS 1732. wastage, overlaps, couplings, welded joints, space bars, chairs, stays, hangers and annealed steel wires or other method of binding & placing shall not be considered for payment) Ground Floor |
| 30 | Construction of Granular sub-base by providing Close graded Granular sub-base Grading Iv materials as per table 400.2, spreading in uniform layers with Motor Grader on prepared surface, mixing by mix-in-place method with rotovator at OMC, and compacting with VRR to achieve the desired density complete as per clause 401 of MoRTH specification for Road and Bridge works (Latest revision) including cost, conveyance royalty and taxes of all material and labour with T&P required for the work etc. complete in all respect as per drawing and Tecnical Specification and as directed by the Engineer-in- Charge (measurement to be taken on finished compacted thickness under OMC compaction). |
| 31 | Providing & laying of 80mm thick cement concrete interlocking paver block of m-40 grade and approved make variety colour and size made by block making machine with strong, vibratory compaction of approved design and shape , laid in required colour and pattern over 50mm thick including cost convayance royality labour with T&P etc complete as per drawing and Technical specification and as directed by the Engineer-in-Charge |
| 32 | Carriage of excavated materials by mechanical means with 5 km initial lead and lift including dressing and levelling the bed etc complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 33 | EI WorksRecessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch legrand( Arteor) /Panasonic (vision) ,Anchor ( Roma) or equievalant reputed make & model ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/L&T/Anchor/Havells/V-Guard) Group-A L.P- 60 F.P- |
| 34 | Group-B L.P- 80 F.P- 50 |
| 35 | Group-C L.P- 20 F.P- 55 C.B.P- 17 |
| 36 | Supply and fixing of 3 pin 5/6 Amps plug with 5/6 Amps switch on existing board Modular switches connection (make-Anchor/ Legrand /) ( 5A Exixting) |
| 37 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, etc. as required. ( 5 A Separate) |
| 38 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6pin 6Amp & 16Amp socket outlet and 16Amp Modular switches (make-Anchor/ Legrand /Roma ( 15 APower plug ) |
| 39 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 02 No.s of 3 Pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required..Modular switches (make-Anchor/ Legrand /Roma) (5A+ 5A switch shocket board) |
| 40 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 01 No.s of 6 pin 15/16A modular socket outlet and 15/16 A modular switch & and 01 no. of 5/6 A modular socket outlet and 5/6 A modular switch , connections etc. as required.Modular switches make-Anchor/ Legrand /Roma) (5+15 A switch shocket board) |
| 41 | S/F of suitable size Modular G.l. box for surface or in recess with Modular base & cover in front including providing and fixing of 6pin 15/16Amp modular socket outlet with 20/25AMP SP MCB of (Hager/L&T/Legrand make) connection, painting etc as required.A.C |
| 42 | Supplying and fixing of Modular G.l. box for suitable module on surface or in recess with Modular base & cover and blanking plate ( if required) in front including providing and fixing of 25AMP DOL starter (ROMA/ Crabtree/Havells make) of modular type switch, connection, painting etc as required as per the direction of Engineer-in-Charge. |
| 43 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Finolex/L&T/Anchor/Havells/V-Guard) |
| 44 | 2 X 1.5sq.mm +1 X 1.5sqmm |
| 45 | 2 X 2.5sq.mm +1 X 1.5sqmm |
| 46 | 2 X 4sq.mm +1 X 1.5sqmm. |
| 47 | (2 x 6 sq.mm + 1 x 2.5 sq.mm) |
| 48 | Supply and fixing of following way single pole and neutral, sheet steel, MCB distribution board consumer unit, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic covr for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB / RCCB / Isolator)12 WAY, DOUBLE DOOR |
| 49 | Supply and fixing of 5Amp to 32A rating 240V \\"B/C\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-Legrand /L&T/C&S) Single pole (SP) |
| 50 | Double Pole (DP) |
| 51 | S/f.of Standard earthing with G.I.earth pipe 4.5m long 40mm dia including all accessories (With chemical powder) with masonary enclosure with coverplate having locking arrangement (Sl.No.5.2.of DSR2022) as per direction of Engineer-in-charge. |
| 52 | Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing along with cables etc as required. |
| 53 | S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose |
| 54 | Supplying and fixing two module steeped type electronic fan regulator with proper modular plate switch box including connections etc. as required.(Make: Legrand(Myrius)/ Anchor(Vision)/ Crabtree(Athena) |
| 55 | Providing and fixing extra down rod of 60 cm length G.I. pipe 20 mm dia heavy gauge of Downrod as per direction of Engineer-in-charge. |
| 56 | Supplying and fixing of Modular G.l. box of 18 SWG on surface or in recess with suitable size Modular base & cover module in front including providing and fixing of Modular Bulbul Callbell of ROMA or Equivalent make with connection, painting etc as required. |
| 57 | Supply and fixing of 9Watt LED Lamp (Philips/ Havells/ AnchorBajaj) |
| 58 | S/F of 20W/18W LED batten light of crompton(slim LINEA /Dazzle ray)/ Havells/ Panasonic or Equivalent make. |
| 59 | S/F of 1x30W 5700K LED street light made up of pressure die cast housing with secondary optics ,IP66 protection Havells make(ENDURA CITYLITE PLATINUM)/ Crompton (ASTRA+) including all accessories and connection as per direction Engineer-in-Charge. |
| 60 | S/F of 1x15W 5700K cool daywhite light surface / recess celing LED light made up of pressure die cast housing with secondary optics ,IP66 protection Havells make((trim) \ of Havells/Crompton or Equivalent make make including fixing on ceiling with grip and Connection as per direction of Engineer-in-Charge.(ext) |
| 61 | S/F of B.H fitting energy saving,surface mounted decorative Hexagonal shape plastic bulk head 1x10Wt LED luminaires comprising high brightness LED with IP54 protection.Make-Havells(Hexa) or Equivalent model of philips/Crompton(TERRACE) |
| 62 | S/F of 4 sq.mm 2 Core Alluminium, armoured LT power Cable of XLPE insulated 650/1100 grade(make-Havells/Polycab) |
| 63 | S/F.of 48\\"A.C.Ceiling fans complete with ISI marked (Usha Striker Galaxy /Usha Super Striker Galaxy/Platinum/Orient(Wendy)/Crompton Greaves Aura Prime Anti-Dust Ceiling Fan (Titanium) |
| 64 | S/F of 300mm metal exhaust fan with wall cutting masonary work including all accessories of USHA (Aeroclean)/ Bajaj (Bahar)/ Crompton or Equivalent make make & connection as per direction of Engineer-in-charge. |
| 65 | Supply, Installation, Testing, and Commissioning of 63 Amp DP Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links,interconnections, earthing, etc. as required as per direction of Engineer in Charge.Make-SEIMENS/ HPL/ ANCHOR/ L&T/HAVELS/C & S/ RK Please Enable Macros to View BoQ information |