Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | 16mm thick cement plaster (1:6) finished smooth to inside 9''/10'' thick brick walls after raking out the joint including watering, curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect as per direction of Engineer in charge. Periferal Wall |
| 2 | 16mm thick cement plaster (1:6) finished smooth to inside 9''/10'' thick brick walls after raking out the joint including watering, curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect as per direction of Engineer in charge. Parapet Wall |
| 3 | 12mm thick cement plaster (1:6) finished smooth to inside 9''/10'' thick brick walls after raking out the joint including watering, curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect as per direction of Engineer in charge. Main Gate |
| 4 | 12mm thick cement plaster (1:6) finished smooth to inside 9''/10'' thick brick walls after raking out the joint including watering, curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect as per direction of Engineer in charge. Panthasala/Choultry |
| 5 | 06 mm thick cement plaster (1:4) finished smooth to inside 9''/10'' thick brick walls after raking out the joint including watering, curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect as per direction of Engineer in charge. Ground Floor |
| 6 | 06 mm thick cement plaster (1:4) finished smooth to inside 9''/10'' thick brick walls after raking out the joint including watering, curing with cost and conveyance of all materials and labour with T&P required for the work with all taxes and royalities etc. complete in all respect as per direction of Engineer in charge. Parapet Wall |
| 7 | Painting two coat with Plastic Emulsion Paint over a coat of primer with two coat of putty to make in even finished surfaces in all floors and heights to wall surface oa pproved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.Ground Floor |
| 8 | Dinning Hall |
| 9 | Providing two coats with Weather coat paint over a coat of primer with two coat of putty on plaster surface of approved shade on new works over a coat of primer to give an even shade including scaffolding to outside walls, including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. Ground Floor |
| 10 | Providing two coats with Weather coat paint over a coat of primer with two coat of putty on plaster surface of approved shade on new works over a coat of primer to give an even shade including scaffolding to outside walls, including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. First Floor |
| 11 | Providing two coats with Weather coat paint over a coat of primer on plaster surface of approved shade on new works over a coat of primer to give an even shade including scaffolding to outside walls, including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. Boundary Wall |
| 12 | C.B Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.Main Gate |
| 13 | C.B Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.Parapet Wall |
| 14 | C.B Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.Panthasala/Choultry |
| 15 | Providing and fixing 20mm thick mirror polished granite stone in dadoo skirting, machine cut stone (sample of granite should be approved by EIC) for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. laid over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In all floors and all heights etc. required for the work all complete as per direction of the Engineer-in-charge |
| 16 | Providing and fixing 20mm thick mirror polished granite stone slab, machine cut stone (sample of granite should be approved by EIC) for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. laid over 25mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In all floors and all heights. etc. required for the work all complete as per direction of the Engineer-in-chargeGround floor |
| 17 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustarde of Size 32mmx32mmx2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification buffing polishing etc. including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge |
| 18 | Providing & laying of 80mm thick cement concrete interlocking paver block of m-40 grade and approved make variety colour and size made by block making machine with strong, vibratory compaction of approved design and shape , laid in required colour and pattern over 50mm thick including cost convayance royality labour with T&P etc complete as per drawing and Technical specification and as directed by the Engineer-in-Charge |
| 19 | Construction of Granular sub-base by providing Close graded Granular sub-base Grading VI materials as per table 400.2, spreading in uniform layers with Motor Grader on prepared surface, mixing by mix-in-place method with rotovator at OMC, and compacting with VRR to achieve the desired density complete as per clause 401 of MoRTH specification for Road and Bridge works (Latest revision) including cost, conveyance royalty and taxes of all material and labour with T&P required for the work etc. complete in all respect as per drawing and Tecnical Specification and as directed by the Engineer-in- Charge. |
| 20 | Filling in foundation trenches and plinth, with Stone Dust of approved quality including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. |
| 21 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. In depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only).Ground Floor |
| 22 | Cement concrete of prop.(1:3:6) in foundation and floors up to lowest bed level using hard black granite crusher broken metal of size 40 mm size down graded of approved quality from approved quarry as per approved design including hoisting,lowering,laying compacting concrete in layers not exceeding 6” thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc., complete in all respects including dewatering if required as per direction of Engineer-in-Charge. |
| 23 | Cement concrete of prop.(1:2:4) in foundation and floors up to lowest bed level using hard black granite crusher broken metal of size 12 mm size down graded of approved quality from approved quarry as per approved design including hoisting,lowering,laying compacting concrete in layers not exceeding 6” thick, watering, curing for three weeks shuttering the exposed surfaces, finished smooth, providing grooves of beads where necessary including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc., complete in all respects including dewatering if required as per direction of Engineer-in-Charge. |
| 24 | Supplying and fixing of precast kerb stone of size 300x600x150mm of M-30 grade of approved make design colour and sizes including cost, conveyance, royalty, & taxes of all materials, with labour, T&P required for the work etc as per direction of Engineer-in-Charge. |
| 25 | Painting two coat with approved Synthetic enamel Paint on steel work to make in even finished surfaces in all floors and heights to Iron surface of approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 26 | Painting two coat with approved Synthetic enamel Paint on steel work to make in even finished surfaces in all floors and heights to Iron surface of approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.Panthasala/Choultry |
| 27 | Earth work in excavation of foundation trenches in All kinds of Soil with all leads & lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site with dressing and levelling the bed and depositing the excavated earth at places away from work site and stacking of useful materials near by the work site with all leads and lifts including cost of all labour and T&P for the works etc. complete as directed by the Engineer-in-charge. |
| 28 | Disposal of Excavated earth by mechanical means to fromt the work site with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. |
| 29 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. |
| 30 | R.C.C.work of Grade M-20 having a minimum compressive strength in work test of 250kg/Cm2 in 15cm cubes at 28 days after mixing and tests conducted in accordance with IS 456 & IS 516 using 20mm down graded size black crusher broken hard granite stone chips of approved quality & from approved quarry including hoisting, lowering & laying concrete & compacting by using vibrators, watering & curing for 4 (four) weeks centring, shuttering & finishing the exposed surface smooth providing grooves or beads where necessary including cost & conveyance royalties & taxes of all materials & labour required for the work etc., complete in all respect but excluding cost & conveyance of M.S.Rods or tor steel and binding wires of 18 to 20 gauge & labour charges for straightening, cutting, bending etc.,of the HYSD Rods or tor steel & binding wires & laying the grills placing in proper position as per direction of Engineer-in-Charge.Footing |
| 31 | Footing Base in wall |
| 32 | Column |
| 33 | Plinth Beam |
| 34 | Roof Beam |
| 35 | Roof Slab |
| 36 | Drain Cover Slab |
| 37 | Panthasala/ ChoultryColumn |
| 38 | Roof Beam |
| 39 | Lintle |
| 40 | Roof Slab |
| 41 | Shelves |
| 42 | Stair Case |
| 43 | Supplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-500) steel of approved manufacturer as per section 1600 §ion 1900 of MORT&H specification for Road and Bridge works including cost, conveyance and taxes of all materials, binding wires 18 to 20 gauge and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. (weight of reinforcement sall be calculated on the basis of IS 1732. wastage, overlaps, couplings, welded joints, space bars, chairs, stays, hangers and annealed steel wires or other method of binding & placing shall not be considered for payment) |
| 44 | Panthasala/Choultry |
| 45 | UPVC Window |
| 46 | UPVC Door frame |
| 47 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge |
| 48 | Supplying, fitting, fixing of all types of MS Grills made of ISI marked standard MS Angles of approved thickness and quality of approved Manufacturers with all required iron and aluminum fittings, including mending to sizes supplying and fixing hinged cleats, sand blocks and fixing of oxidized iron or chromium plated iron aldrops, tower bolts, knobs or rings or handles, hinges, screws and other fittings, etc. complete as per requirement including cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge. |
| 49 | Supplying, fitting & fixing of 8-10 mm thick & size of 600x600 mm Vetrified floor tile of matt finish with veilcraft (VC/FT ) shield( Scratch free/stain free) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge |
| 50 | Supplying, fitting & fixing of 8-10 mm thick and size of 600x600 mm vertified wall tile of in dadoes, skirting and risers of steps of laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. |
| 51 | Providing, fixing retro-reflectorised, cautionary, mandatory & informatory sign as per IRC-67 made of high intensity gr. aluminium sheeting 1.5mm thick supported on MS circular pipe 65 NB firmly fixed to the ground by means of PCC M25 grade foundation of 45cm x 45cm x 60cm, 60cm below ground level as per drawing and Clause 801 of MoRT&H Specifications for Road & Bridge works etc. complete as per technical specification and direction of Engineer-in-Charge.1200x900 mm size |
| 52 | 800x600mm size |
| 53 | 90cm high octagon |
| 54 | EI WorksRecessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch legrand( Arteor) /Panasonic (vision) ,Anchor ( Roma) or equievalant reputed make & model ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/L&T/Anchor/Havells/V-Guard) Group-A L.P- 30 F.P- |
| 55 | Group-B L.P- 60 F.P- 20 |
| 56 | Group-C L.P- 30 F.P- 20 C.B.P- |
| 57 | Wiring for twin control light point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess PVC conduit with 2 way Modular type switch, Modular plate, suitable GI Box and earthing point with 1.5 sq.mm FR PVC insulated single core multistrand Modular switches connection (make-Anchor/ Legrand /Roma) or equievalant reputed make & model ISI marked as per the direction of EIC. ( Twin control) |
| 58 | Supply and fixing of 3 pin 5/6 Amps plug with 5/6 Amps switch on existing board Modular switches connection (make-Anchor/ Legrand /) ( 5A Exixting) |
| 59 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, etc. as required. ( 5 A Separate) |
| 60 | Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6pin 6Amp & 16Amp socket outlet and 16Amp Modular switches (make-Anchor/ Legrand /Roma ( 15 APower plug ) |
| 61 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 02 No.s of 3 Pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required..Modular switches (make-Anchor/ Legrand /Roma) (5A+ 5A switch socket board) |
| 62 | S/F of suitable size Modular G.l. box for surface or in recess with Modular base & cover in front including providing and fixing of 6pin 15/16Amp modular socket outlet with 20/25AMP SP MCB of (Hager/L&T/Legrand make) connection, painting etc as required.A.C |
| 63 | Supplying and fixing of Modular G.l. box for suitable module on surface or in recess with Modular base & cover and blanking plate ( if required) in front including providing and fixing of 25AMP DOL starter (ROMA/ Crabtree/Havells make) of modular type switch, connection, painting etc as required as per the direction of Engineer-in-Charge. |
| 64 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in surface /recessed PVC conduit as required (make of wire -Finolex/L&T/Anchor/Havells/V-Guard) 2 X 1.5sq.mm +1 X 1.5sqmm |
| 65 | 2 X 2.5sq.mm +1 X 1.5sqmm |
| 66 | 2 X 4sq.mm +1 X 1.5sqmm. |
| 67 | 4 X 10sq.mm +2 X 4sqmm. |
| 68 | Supply and fixing of following way single pole and neutral, sheet steel, MCB distribution board consumer unit, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic covr for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB / RCCB / Isolator) 8 WAY, DOUBLE DOOR (UPS DB) |
| 69 | 4 WAY (4 + 12) DOUBLE DOOR, HORIZONTAL TYPE |
| 70 | Supply and fixing of 5Amp to 32A rating 240V \\"B/C\\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-Legrand /L&T/C&S) Single pole (SP) |
| 71 | Double Pole (DP) |
| 72 | 63 A Triple Pole Neutral (TPN) |
| 73 | S/f.of Standard earthing with G.I.earth pipe 4.5m long 40mm dia including all accessories (With chemical powder) with masonary enclosure with coverplate having locking arrangement (Sl.No.5.2.of DSR2022) as per direction of Engineer-in-charge. |
| 74 | Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing along with cables etc as required. |
| 75 | S/F.of Special earthing complete with provision of 600x600x3mmthick or (2ft x 2ft) copper plate, 38/40mm dia 3mtr long G.I.pipe , 25x3mm thick Cu.flat charcoal and salt/ chemical powder ,funel,earthpit chamber with masonary work including all accessories and connection as per direction of Engineer-in-charge( |
| 76 | Providing and fixing earth bus of 50mm X 5mm copper strip on surface connection etc as required. |
| 77 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 78 | S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose |
| 79 | Supplying and fixing two module steeped type electronic fan regulator with proper modular plate switch box including connections etc. as required.(Make: Legrand(Myrius)/ Anchor(Vision)/ Crabtree(Athena) |
| 80 | Providing and fixing extra down rod of 60 cm length G.I. pipe 20 mm dia heavy gauge of Downrod as per direction of Engineer-in-charge. |
| 81 | Supplying and fixing of Modular G.l. box of 18 SWG on surface or in recess with suitable size Modular base & cover module in front including providing and fixing of Modular Bulbul Callbell of ROMA or Equivalent make with connection, painting etc as required. |
| 82 | Supply and fixing of 9Watt LED Lamp (Philips/ Havells/ AnchorBajaj) |
| 83 | S/F of 20W/18W LED batten light of crompton(slim LINEA /Dazzle ray)/ Havells/ Panasonic or Equivalent make. |
| 84 | S/F of 1x15W 5700K cool daywhite light surface / Recess celing LED light made up of pressure die cast housing with secondary optics ,IP66 protection Havells make((ENDURA NEO DL SURFACE/ INTEGRA NEO SURFACE) \ of Havells/Crompton or Equivalent make make including fixing on ceiling with grip and Connection as per direction of Engineer-in-Charge.(ext) |
| 85 | LED Bulk head Light fitting (1000 Lumen) of make BAJAJ .(CAT No:BIBWP 10W LED)/ Equivalent /Philips/Lighting Technologies. |
| 86 | S/F of 90 W LED street light fitting (Make-Crompton /Havels /Philips /Bajaj) |
| 87 | S/F of Gate/ Lawn light fitting with 25W LED as luminarie (Make-Bajaj/ Philips / Crompton/ Havells) (Make-Havells/Philips/C&S/Crompton) |
| 88 | S/F.of 48\\"A.C.Ceiling fans complete with ISI marked (Usha Striker Galaxy /Usha Super Striker Galaxy/Platinum/Orient(Wendy)/Crompton Greaves Aura Prime Anti-Dust Ceiling Fan (Titanium) |
| 89 | S/F of Wall Mounted Fan including all accessories of USHA(Mist Air Icy Blue)/Crompton (Wall Mounted Fan-High Flo LG 18\\") make & connection as per direction of Engineer-in-charge. |
| 90 | S/F.of 600 mm high speed Ceiling Fan,(Havells /Usha Striker)/ Orient |
| 91 | S/F of 300mm metal exhaust fan with wall cutting masonary work including all accessories of USHA (Aeroclean)/ Bajaj (Bahar)/ Crompton or Equivalent make make & connection as per direction of Engineer-in-charge. |
| 92 | Electrical Inspection charges for building |
| 93 | Supply of Insulation mats Class A insulation of size 1Mx2Mx2mm. |
| 94 | S/F of Electrical safety acrylic chart/Poster depicted with various safety precautions , management and provides information to perform First Aid in case of electric shock etc in English and odia language with Multi color images and sign |
| 95 | S/F of double battery of 150AH with 2KVA Inverter of Make Luminous/Exide/Sfsonic including all accessories and connection as per direction of Engineer-in-charge. |
| 96 | Supply of double battery inverter trolly of PVC ( Reputed make as per the direction of EIC) |
| 97 | POWER GENERATING SYSTEM COMBO SUPPLY 10 KWp 120V*Rayzon Solar Mono Half Cut Module 550Wp * 18 Nos. (NON-DCR) *Solar MPPT PCU 10KVA(8KW)120V, 1 Ph * 1 Nos.(STATCON ENERGIAA) *Solar C10 Battery 12V200AH * 10 Nos. (Eastman) *Battery Rack * 1 Nos.*Module Mounting G.I. Ground Structure * 1 Set*Solar DC Cable 10 sq.mm 1 Core: 60 Mtr *Solar DC Cable 4 sq.mm 1 Core: 50 Mtr *ACDB 10 KW 1 Phase * 1 Nos.*63A Change Over Switch 1 PH * 1 Nos.*MC4 Connector * 5 Pair*Lightening Arrestor * 1 Nos.*Chemical Earthing Kit * 3 Nos.*16 sq.mm Aluminum Cable 1 Core * 15 Mtr*6 sq.mm Aluminum Cable 1 Core * 60 Mtr*10 sq. mm Copper Cable 1 Core * 20 Mtr Fittings & Fixtures*25 mm PVC Conduit Pipe * 15 Nos.*25 mm PVC C-Clip * 50 Nos.*25 mm PVC Elbow * 25 Nos.*25 mm PVC \\"T\\" * 5 Nos.*Flexible Pipe * 10 Mtr*Cable Tie * 30 Nos.*PVC Tape * 2 Nos.*Battery Cabling With Ring Socket * 1 SetInstallation & Commisioning Charges |
| 98 | S/F of 6 sq.mm 2 Core Alluminium, armoured LT power CableWith G.I Stay Wire of XLPE insulated 650/1100 grade (makeHavells /Polycab) |
| 99 | S/F of 2.5 sq.mm 2 Core Copper, unarmoured flexible LT Cable 650/1100 grade (makeHavells /Polycab/KEI/RR) |
| 100 | Supply and laying of 63mm (2 inch) HDPE pipe of PN6 grade of wall thickness of min 3 mm and max 3.5mm including all accessories and connection osq.mm (make-Sudhakar)ncluding excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as |
| 101 | S/F of Street Light Panel 3 Phase, Frame Size 1, Max. Load10 kW, Digital 24 Hr. Timer, Contactor Rating (A) 32/TP, 40 / TPN MCB Rating of Havells make including all accessories and connection. |
| 102 | S/F of 16 sq.mm 4 Core Alluminium, armoured LT power Cable main insulated 650/1100 grade(make-Havells/Polycab) (5Omtr for High Mast) |
| 103 | S/F 1X40W New generation, LED post-top latern , energysaving, environmental friendly, long life aesthetically designedwith symmetrical light distribution, spun aluminium landscapeluminaire with high power LEDs as light source. ofHavells(RUBY CLEAR/CORAL OPAL)/crompton/Halonixmake with suitable size of G.I pipe for Fitting and all accessories |
| 104 | Supply of 3Mtr Ornamental MS pole (bottom section 1mtr long, 114mm dia 3.65mm thick pipe, : Top section 2mtr long ,90mm dia Make Halonix (Pro Slice Pole)/bajaj/Havells or Equivalent make |
| 105 | Cement concreting for pole CC foundation 1:3:6 size by using 4cm size HBG metal(=0.5X0.5x1.5=0.375Cum including eexcavation and filling as reqiured |
| 106 | S/F of 1x200W 5700K LED Flood light made up of pressure die cast housing with toughned glassindividual high powered LEDs with secondary optics ,IP66 protection Havells make(JETA IRIS )/ Crompton/Philips/Panasonic/Wipro/ Halonix make including all accessories and connection as per E.I.C (9 Nos for High mast) |
| 107 | S/F of 1x30W Flood light made up of pressure die cast housing with toughned glassindividual high powered LEDs with secondary optics ,IP66 protection Havells make JETA QUANTO )/ Halonix/Crompton make including all accessories and connection as per E.I.C(inside temple) |
| 108 | Suplying Of 15W LYCUS LED SPIKE/BUSH focus LIGHT LYCUSSPS15WLED730PSYMBOTG Environmental friendly, new generation, energy saving, decorative IP66 LED spike light using COB LED as light source.(inside temple) |
| 109 | Suplying Of 15W CLIO LED WALL DECORATIVE LIGHT CLIOLL15LED730PSYMTOTUGEnvironmental friendly, new generation, energy saving, decorative IP66 LED spike light using COB LED aslight source.(wall washer) |
| 110 | Suplying Of 10W UNECO TRACK/SPOT LIGHT HLDLSS-44-10-WW-CYL Environmental friendly, new generation, energy saving, decorative IP66 LED spike light using COB LED as light source. |
| 111 | Suplying and fixing of ACP board with SMPS, LED Letter for name plate size 16 ftx3.5ft. |
| 112 | Suplying and Installation Of single color/MulticolorLED flexible strip light of 50 mtr with driver,IP-65.(for temple building) |
| 113 | VENTILATION EXHAUST FANS Ducting & GrillsRectangular GI Ducting Supply, installation, balancing and commissioning of factory fabricated G.S.S. (Class VIII 120 GSM) rectangular ducting complete with neoprene rubber gaskets, elbow, splitter dampers, vanes, hangers, supports etc as per approved drawings and confirming to SMACNA standard of following sheet thickness complete as required inluding GI jalli at inlet and outlet end as required 22 G (0.8 mm) |
| 114 | Supplying, installation, testing and commissioning of following direct driven 200mm Inline type fan and casing suitable for smoke exhaust application & for 300 Deg C for 2 hours Class F rating. Motor shall be suitable for 220 Volt ,1297 RPM 50 c/s, 3 ph AC,0.15kW, 4Pole supply and of efficiency class IE2.The fan shall be equipped with mounting bracket & outlet cone required at discharge. (Make ELTA or Equivalent) 700 cfm |
| 115 | 16 MTRS HIGH MAST FABRICATED PART AS PER DIMENSION:TOPDIA. 150 mm, BOTTOM DIA 360 mm, SECTION 2 nos. (SECTIONLENGTH 8300) THICKNESS 4,3 mm. BASE PLATE Dia. 520 mm X25 mm., PCD 445 mm, with following items: High Mast sections withBase Plate, Lantern Carriage suitable to fix up to 9 nos. (200 W LED)luminaries symmetrically in 9 nos. welded arm, 3 suspension Headframe, L-Stopper (3 Nos.), Mounting Plates, Lightening Arrestor andEarthing Pipe (MS GI). 16 MTR LIGHTING MAST ACCESSORIES PART: Double Drum Winch 350 Kg. (Gear Ratio 53:1), 1 HP Motor (3Ph, 230 V) , Ø6 mm.SS Wire Rope (Grade-AISI 316 ), Manual Operating Handle, TrailingCable (1 sets 5 core x 2.5 sq. mm. EPR PCP Round Copper), GIJunction Box. (Without AOL, Plug-Socket & Feeder Pillar-ControlSwitch, Luminaries) FOUNDATION ACCESSORIES: Bolt M30 x 850 (8 Nos.) withTemplate and Anchor Plate ( including transportation) of reputaed make make including all accessories and connection as per E.I.C (make-Utkarsh/Valmont/Bajaj) |
| 116 | Supply of outdoor stand mounted Feeder Panel of reputaed make make including all accessories and connection as per E.I.C |
| 117 | Supply of Single type aviation dome obstruction LED light fittingof reputaed make including all accessories and connection as per E.I.C |
| 118 | Construction of R.C.C foundation for erection of 16 Mtr High Mast |
| 119 | High Mast Installation including Hydra |
| 120 | FIRE FIGHTING SYSTEM Supply & fixing of Terrace tank (5000 ltr) Fiber Water tank triple layer unbrakable extra thick and flexible material for long life new UV threaded lid to keep dust particles out with all needed accessories. (make-intex/Ashirvad/Supreme) |
| 121 | Supplying, Installing, testing and commissioning of C.I. wafer type butterfly valves as per BS 5155 slim seal standared lever operated type with required flanges, nuts, bolts etc. complete. Make-Audco/Zoloto/Leader. 100mm nominal dia |
| 122 | Supply , installation ,testing and commissioning of Isolation Sluice valves tested to ISI marked ,PN 1.6 with CI body, bonnet & brass trim parts, & having necessary companion flanges, bolts, nuts, gasket including indicator for open and shut position to be installed. (Make-Kartar) 100mm NB |
| 123 | Supplying, installing, testing and commissioning of C.I. waffer type Non-return valves ( PN 16 ) swing check type with required flanges, nuts, bolts and gaskets etc. complete. Make-Audco/Zoloto/Leader. 100mm NB |
| 124 | Supply and installation testing and commissioning of Pressure gauges of suitable range (0-16 bar), 100 mm diameter dial for pumpsets completes with necessary Ball valves, siphon, Fittings like unions / colors / reducers etc. Make- H Guru/G Guru. |
| 125 | Supply and installation testing and commissioning of differential Pressure switches of suitable range (0 to 12 bar) for pumpsets complete with necessay Ball valves, Fittings like unions / colors / reducers etc. Make- Danfoss/Grundfoss/Indfoss. |
| 126 | Supply, Installation of structural steel like ( Beam , Channel, Angle, Plate & Sheet) made of size min 100mmx50mm channel of thickness minimum 6mm and also tank base plate of thickness 6mm for 2 nos terrace tank base & barricade .(Make-SAIL/JINDAL/TATA) |
| 127 | Supply, Installation,Testing and Commissioning of 1\\" Air Release Valve with all accessories as per direction of Engineer-in-charge.(make-Kartar) |
| 128 | Supply, Installation,Testing and Commissioning of 2 - way fire brigade connection with all accessories as per direction of Engineer-in-charge.. |
| 129 | Supplying, installation testing and commissioning of the following. ‘C' class MS pipe as per IS 1239 with welded / flanged / with heavy clamps, hangers, brackets or pipe supports as required including MS pipe of shorter lengths, tapering connecting pieces, short or long bends, forged specials like sockets, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities. The pipes will have to be laid and fixed on walls, ceilings, into brick walls or RCC with lead anchor fasteners to the satisfaction of the Consultant/Client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes. Make TATA/Sail/Jindal 100mm NB |
| 130 | 80 mm NB |
| 131 | 25 mm NB |
| 132 | Supplying, erecting and commissioning of Hydrants Single headed hydrant valve as per IS 5290, made of SS with 63 mm dia instantaneous outlet of 80 mm dia fanged inelt ,Blank caps , chain and hand wheels etc complete. Make: Newage/Minimax/ Fireshield/Kartar. |
| 133 | SITC of SS short branch pipe with nozzle conforming to IS 903. Make: Newage/Minimax/ Fireshield/Kartar. |
| 134 | Providing & fixing 63mm dia 15 meter long RRL hose pipe as per IS 636 TYPE A TAC/ LFA approved of standard length of approved pattern and size including ss male and female Coupling duly bound with copper wire etc. complete(Make-CRC) |
| 135 | Supplying and fixing MS hose box of suitable size made of 1.6 mm thick MS sheet with double door arrangement , front door fixed with full glass and locking arrangement to accomodate two nos. 63 mm dia RRL hose reel , one no. branch pipe with powder coated and postal red finishing along with all accessories etc as required.The hose box size is 750 mm x 600 mm x 300 mm (MAke-Winco) |
| 136 | Supply and installation, testing and commissioning of NRV conforming to API 594/598 (dual plate check type) with CI body & trim part, PN 1.6 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved. (Make-KArtar) 100mm NB |
| 137 | SITC of First aid Hose reel drum of 180° swinging type with 19mm dia Rubber braided hose of 30M. length with Ball Valve and 6mm diameter Shut off nozzle, complete. The hose reel shall conforming to IS 884 Make: Newage/Minimax/ Fireshield.(Make-Mitras) |
| 138 | Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type. 25 mm nominal dia Make-Audco/Zoloto/Leader/KArtar. 25 mm |
| 139 | 15 mm |
| 140 | Supply, Installation, Testing and Commissioning of electric motor driven Terrace booster pump capable to deliver 450 LPM at 36 mtr head ,7.5 HP, 3 phase.(make-Kirloskar) |
| 141 | Supply, installation, testing and commissioning of 32mm SDR11 upvc pipes of 60mtr length for filling line from existing tank to fire water tank on terrace floor on with Tees,Elbows, Ball valve , Tank connector, coupler end cap, etc all accessories , clamping on wall surface as required .(make-Supreme/Astral/Finolex/Sudhakar) |
| 142 | Supply , Installation,Testing and Commissioning of MCC cum Starter control panel (7.5 HP)for Terrace pump sets with incomer and selector switch for standby and working and auto/manual operation and necessary annunciation asper direction of Engineer-in-charge.(Make-Powertech) |
| 143 | Supply , Installation,Testing and Commissioning of Power cable (4 C X 10 SQMM) with clamping on wall surface as required for motor run from Panel of the pump system as per direction of Engineer-in-charge.(Make-Polycab/Havells/KEI/RR/Finolex) |
| 144 | Supply , Installation,Testing and Commissioning of Control cable (3C X 1.5 SQMM) with clamping on wall surface as required for establishing automation Panel of the pump system as per direction of Engineer-in-charge.(Make-Polycab/Havells/KEI/RR/Finolex) |
| 145 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire |
| 146 | 6 Kg ABC (Powder Type) Fire Extinguisher In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 (Make-Safex/Fireshield/Ceasefire) |
| 147 | Supply, Installation of Fire bucket 3 nos with stand |
| 148 | Supply, Installation of Pump protection shed on terrace made by structural steel & sheet |
| 149 | Way to exit signage at each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground. Size shall be 15cm x 60cm. |
| 150 | Supplying and installing of in position the signages \\" FIRE ORDER\\" it should contain the following matter on 3mm thick \\"Opaque\\" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3' x 4'. as per BIS Specification.a. A) evacuate the occupants by obeying fire exits / way to exit and emergency exits only and assemble at various assembly points. (B) if possible try to extinguish the fire by using nearest / suitable portable extinguisher or water from nearest wet riser. C) be calm and do not give any room from panic, walk, do not run. (D) if you encounter serious difficulty in evacuation, flat and try to attractattention of rescue team. |
| 151 | Fire hose reel (Size:6\\" X 4\\") |
| 152 | Fire extinguishers (Size:6\\" X 4\\") |
| 153 | PH WorksProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20mm dia C-PVC pipe SDR-11 First Floor |
| 154 | 25mm dia C-PVC pipe SDR-11 First Floor |
| 155 | 32mm dia C-PVC pipe SDR-11 |
| 156 | 40mm dia C-PVC pipe SDR-11 |
| 157 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 15mm dia CP angle stop cock (Jaquar)CON-CHR-059KN |
| 158 | 15mm dia CP two way bib cock (Jaquar)CON-041KN |
| 159 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 160 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 161 | 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
| 162 | 25mm dia CP Health Faucet (Jaquar Make)ALD - CHR - 565 |
| 163 | 25mm dia brass full way valve (Shakti make) |
| 164 | 32mm dia brass full way valve (Shakti make) |
| 165 | 40mm dia brass full way valve (Shakti make) |
| 166 | 15mm CP Extension piece |
| 167 | 125mm CP grating |
| 168 | 15mm size C.P. flange |
| 169 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank roof of 1st Floor |
| 170 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 171 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge |
| 172 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
| 173 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 174 | 110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
| 175 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 176 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 177 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 178 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 179 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 180 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 181 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 182 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 183 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 184 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge European water closet with 'p' trap plain(Hindware/Parryware/Neycer make) |
| 185 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge Halfpedestal basin(560x450)Hindware No.91049+91115 |
| 186 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 187 | CP towel Ring |
| 188 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 189 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. |
| 190 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. 600mmx450mm size Frammed mirror |
| 191 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. ½” x 5” CP Shower (Plaza Deluxe Make) |
| 192 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 193 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 194 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 195 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge )Kajaria/Somany/Johnson/RAK/Oasis tile 60cmx60cm |
| 196 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 197 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge ) Kajaria/Somany/Johnson//RAK/Oasis tile 45cmx30cm |
| 198 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 199 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 200 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liter's along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge |
| 201 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 110mm dia u-pvc pipe alround concrete |
| 202 | 160mm dia u-pvc pipe alround concrete |
| 203 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge |
| 204 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size 76cmx76cmx46cm with 18” dia RCC MH cover |
| 205 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) |
| 206 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 207 | 50 Users septic tank of size Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 208 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 209 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 210 | Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete. |
| 211 | Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site. |
| 212 | Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. |
| 213 | Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor. RCC floor, roof slab chhaja up to 4.430 m height |
| 214 | Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site. |
| 215 | Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site. |
| 216 | Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site. Same as plaster |
| 217 | Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. |
| 218 | Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. |
| 219 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. |
| 220 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessoriesLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 30mtr |
| 221 | Drilling of 200mm dia bore30 mtr to 45mtr |
| 222 | Drilling of 150mm dia bore 45 mtr to 195.00mtr |
| 223 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200mm dia P.V.C casing pipes00 mtr to 30 mtrs |
| 224 | 30 mtr to 60mtr |
| 225 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. |
| 226 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 227 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 228 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:Rocky terrain with boulder formation for 300m depth |
| 229 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 230 | DOL Control panel |
| 231 | 40mm dia steel short piece |
| 232 | Well cap |
| 233 | 50mm size CI bracket |
| 234 | 2.50sqmm flat cable |
| 235 | 20mm dia rigid UPVC pipes |
| 236 | Steel rope with cover |
| 237 | Labour charges for lowering including transportation |
| 238 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge32mm HDPE pipes (Finolex/Supreme make Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy