Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Proposed Construction of Type-B (16 Nos) of Residence at Mehnagar Thana in District-Azamgarh |
| 2 | (A)- TYPE- II RESIDENCE |
| 3 | (a)- CIVIL WORKS |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 5 | Supplying and filling in plinth with sand under floor, including watering,ramming,consolidating and dressing complete. |
| 6 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel 1:3:6 (1 Cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 8 | RCC WORK UPTO PLINTH |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. |
| 10 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 11 | All works upto plinth level |
| 12 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 13 | R.C.C. work in Plinth beams |
| 14 | R.C.C. work in Raft foundation |
| 15 | R.C.C. Work in Column |
| 16 | RCC WORK ABOVE PLINTH |
| 17 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. |
| 18 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 19 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 20 | R.C.C. work in Lintel |
| 21 | All works above plinth level upto floor V level |
| 22 | First Floor |
| 23 | Second Floor |
| 24 | Third Floor |
| 25 | Fourth Floor |
| 26 | Fifth Floor |
| 27 | Sixth Floor |
| 28 | Sseventh Floor |
| 29 | Eighth Floor |
| 30 | R.C.C. work in slab |
| 31 | All works above plinth level upto floor V level |
| 32 | Stilt Floor |
| 33 | First Floor |
| 34 | Second Floor |
| 35 | Third Floor |
| 36 | Fourth Floor |
| 37 | Fifth Floor |
| 38 | Sixth Floor |
| 39 | Seventh Floor |
| 40 | Eighth Floor |
| 41 | Terrace Floor |
| 42 | R.C.C. work in beams |
| 43 | All works above plinth level upto floor V level |
| 44 | Stilt Floor |
| 45 | First Floor |
| 46 | Second Floor |
| 47 | Third Floor |
| 48 | Fourth Floor |
| 49 | Fifth Floor |
| 50 | Sixth Floor |
| 51 | Seventh Floor |
| 52 | Eighth Floor |
| 53 | Terrace Floor |
| 54 | R.C.C. Work in Column |
| 55 | All works above plinth level upto floor V level |
| 56 | Stilt Floor |
| 57 | First Floor |
| 58 | Second Floor |
| 59 | Third Floor |
| 60 | Fourth Floor |
| 61 | Fifth Floor |
| 62 | Sixth Floor |
| 63 | Seventh Floor |
| 64 | Eighth Floor |
| 65 | Terrace Floor |
| 66 | Add for using extra cement in the items of design mix over and above the specified cement content therein. DSR-5.35 |
| 67 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR-5.22.6 |
| 68 | Upto plinth level |
| 69 | Stilt Floor |
| 70 | First Floor |
| 71 | Second Floor |
| 72 | Third Floor |
| 73 | Fourth Floor |
| 74 | Fifth Floor |
| 75 | Sixth Floor |
| 76 | Seventh Floor |
| 77 | Eighth Floor |
| 78 | Terrace Floor |
| 79 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 80 | Brick work with bricks of class designation 15 (Class-150) in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand (FM 1.50 to 2.00)) |
| 81 | Stilt Floor |
| 82 | First Floor |
| 83 | Second Floor |
| 84 | Third Floor |
| 85 | Fourth Floor |
| 86 | Fifth Floor |
| 87 | Sixth Floor |
| 88 | Seventh Floor |
| 89 | Eighth Floor |
| 90 | Terrace Floor |
| 91 | Half brick masonry with bricks of class designation 15 (Class-150) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand (FM 1.50 to 2.00)) |
| 92 | First Floor |
| 93 | Second Floor |
| 94 | Third Floor |
| 95 | Fourth Floor |
| 96 | Fifth Floor |
| 97 | Sixth Floor |
| 98 | Seventh Floor |
| 99 | Eighth Floor |
| 100 | Terrace Floor |
| 101 | 12 mm cement plaster of mix : 1: 6 (1 cement : 6 coarse sand) |
| 102 | Stilt Floor |
| 103 | First Floor |
| 104 | Second Floor |
| 105 | Third Floor |
| 106 | Fourth Floor |
| 107 | Fifth Floor |
| 108 | Sixth Floor |
| 109 | Seventh Floor |
| 110 | Eighth Floor |
| 111 | Terrace Floor |
| 112 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement : 6 coarse sand) |
| 113 | Stilt Floor |
| 114 | First Floor |
| 115 | Second Floor |
| 116 | Third Floor |
| 117 | Fourth Floor |
| 118 | Fifth Floor |
| 119 | Sixth Floor |
| 120 | Seventh Floor |
| 121 | Eighth Floor |
| 122 | Terrace Floor |
| 123 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. |
| 124 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm (Granite of any shade) |
| 125 | First Floor |
| 126 | Second Floor |
| 127 | Third Floor |
| 128 | Fourth Floor |
| 129 | Fifth Floor |
| 130 | Sixth Floor |
| 131 | Seventh Floor |
| 132 | Eighth Floor |
| 133 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 134 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-lll) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%) |
| 135 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm DSR 11.41.2 |
| 136 | First Floor |
| 137 | Second Floor |
| 138 | Third Floor |
| 139 | Fourth Floor |
| 140 | Fifth Floor |
| 141 | Sixth Floor |
| 142 | Seventh Floor |
| 143 | Eighth Floor |
| 144 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to |.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 DSR 11.46.2 |
| 145 | First Floor |
| 146 | Second Floor |
| 147 | Third Floor |
| 148 | Fourth Floor |
| 149 | Fifth Floor |
| 150 | Sixth Floor |
| 151 | Seventh Floor |
| 152 | Eighth Floor |
| 153 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 154 | Stilt Floor |
| 155 | First Floor |
| 156 | Second Floor |
| 157 | Third Floor |
| 158 | Fourth Floor |
| 159 | Fifth Floor |
| 160 | Sixth Floor |
| 161 | Seventh Floor |
| 162 | Eighth Floor |
| 163 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 164 | Stilt Floor |
| 165 | First Floor |
| 166 | Second Floor |
| 167 | Third Floor |
| 168 | Fourth Floor |
| 169 | Fifth Floor |
| 170 | Sixth Floor |
| 171 | Seventh Floor |
| 172 | Eighth Floor |
| 173 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 174 | First Floor |
| 175 | Second Floor |
| 176 | Third Floor |
| 177 | Fourth Floor |
| 178 | Fifth Floor |
| 179 | Sixth Floor |
| 180 | Seventh Floor |
| 181 | Eighth Floor |
| 182 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 183 | Stilt Floor |
| 184 | First Floor |
| 185 | Second Floor |
| 186 | Third Floor |
| 187 | Fourth Floor |
| 188 | Fifth Floor |
| 189 | Sixth Floor |
| 190 | Seventh Floor |
| 191 | Eighth Floor |
| 192 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : |
| 193 | (a) 35mm thick Single leaf |
| 194 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. |
| 195 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). DSR 9.53 |
| 196 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (by weight) DSR 9.48.1 |
| 197 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)( Z section windows) (by weight) DSR 10.11.1 |
| 198 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40X40X5 mm, joints mitred and welded by angle iron 40X40X5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (by weight) DSR 10.31 |
| 199 | Supply and fixing galvanized mosquitos proof heavy quality iron wire guage of expended metal heavy quality over windows and including supply of C.P. teak wood batten 8 cm (3\\"3/8\\") flat iron 25 mm 4 mm and including supply of necessary screws all labour and tools & plant etc required for proper comletion of the work. |
| 200 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters |
| 201 | Sheesham wood |
| 202 | P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. |
| 203 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 204 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type). |
| 205 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 206 | Stilt Floor |
| 207 | First Floor |
| 208 | Second Floor |
| 209 | Third Floor |
| 210 | Fourth Floor |
| 211 | Fifth Floor |
| 212 | Sixth Floor |
| 213 | Seventh Floor |
| 214 | Eighth Floor |
| 215 | Terrace Floor |
| 216 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.43 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 217 | Stilt Floor |
| 218 | First Floor |
| 219 | Second Floor |
| 220 | Third Floor |
| 221 | Fourth Floor |
| 222 | Fifth Floor |
| 223 | Sixth Floor |
| 224 | Seventh Floor |
| 225 | Eighth Floor |
| 226 | Terrace Floor |
| 227 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 228 | Stilt Floor |
| 229 | First Floor |
| 230 | Second Floor |
| 231 | Third Floor |
| 232 | Fourth Floor |
| 233 | Fifth Floor |
| 234 | Sixth Floor |
| 235 | Seventh Floor |
| 236 | Eighth Floor |
| 237 | Terrace Floor |
| 238 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 239 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (a) 250mm x 16mm . |
| 240 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (a) 250 mm x 10mm |
| 241 | Providing and fixing ISI marked oxidised M.S. handles conforming to 1S:4992 with necessary screws etc. complete (Copper oxidised as perIS 1378) (a) 125 mm |
| 242 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 243 | (C ) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e ) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 244 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 245 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 246 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 247 | Providing & laying of light cinder filling/coil under floor of toilets & other sunken roofs. |
| 248 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 249 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. by weight (DSR-10.28) |
| 250 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 251 | Foundations, footings, bases of columns, etc. for mass concrete |
| 252 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 253 | Lintels, beams, plinth beams, girders, buttresses and cantilevers. |
| 254 | Suspended floors, roofs, landings, balconies and access platform. |
| 255 | (B)- INTERNAL WATER SUPPLY & SANITARY WORKS |
| 256 | SUB HEAD - I - (SANITARY FIXTURES & C.P. BRASS FITTING) |
| 257 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 258 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 610x460 mm bowl depth 200 mm |
| 259 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 260 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia |
| 261 | Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore |
| 262 | Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 263 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) 15 mm nominal bore |
| 264 | Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect. |
| 265 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 266 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter |
| 267 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 268 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore 15 mm nominal bore |
| 269 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore |
| 270 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 271 | Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects. (Angle valve to be provide under item no. 18 and measure with that item.) . |
| 272 | SUB HEAD - II - (SOIL, WASTE, RAIN WATER AND VENT PIPES) |
| 273 | RAIN WATER DRAINAGE WORK |
| 274 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarsesand : 10 graded stone aggregate 40 mm nominal size) all-roundS.W. pipes including bed concrete as per standard design : 100 mm dia |
| 275 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 100 mm dia |
| 276 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm |
| 277 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee with door 110x110x110 mm |
| 278 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee without door 110x110x110 mm |
| 279 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110mm bend |
| 280 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110mm shoe |
| 281 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 282 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 283 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 110mm dia pipe. |
| 284 | UPVC SWR SOIL, WASTE & VENT PIPES AND FITTINGS |
| 285 | Cutting holes up to 30x30 cm in walls including making good the same: With With common burnt clay F.P.S. (non modular) bricks |
| 286 | Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof |
| 287 | Internal Toilet (Soil, Waste & Rain Water Pipe) |
| 288 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 110 mm dia. . |
| 289 | Providing and fixing SWR PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 110mm x 110mmX110mm . |
| 290 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (45°) 110mm . |
| 291 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Y' Fitting without door 110mm . |
| 292 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Single Tee without door 110mm . |
| 293 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Coupler 110mm . |
| 294 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Clean Out Plug 110mm . |
| 295 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Vent Cowl 110mm . |
| 296 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 50mm dia. Pipe . |
| 297 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc 40mm dia. Pipe (for wash basin & sunken toilet spout) . |
| 298 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (90°) 50mm . |
| 299 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (90°) 40mm . |
| 300 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (45°) 50mm . |
| 301 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (45°) 40mm . |
| 302 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . T fitting 50mm . |
| 303 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . T fitting 40mm . |
| 304 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Coupler 50mm . |
| 305 | Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Coupler 40mm . |
| 306 | SUB HEAD - III - (WATER SUPPLY) |
| 307 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore |
| 308 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia nominal bore |
| 309 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 15 mm dia nominal bore |
| 310 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 20 mm dia nominal bore |
| 311 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall / Terrace 20 mm dia nominal bore |
| 312 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall / Terrace 25 mm dia nominal bore |
| 313 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall / Terrace 32 mm dia nominal bore |
| 314 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall / Terrace 40 mm dia nominal bore |
| 315 | Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc External work. 65 mm dia nominal bore |
| 316 | Painting G.I. pipes and fittings with synthetic enamel white paintwith two coats over a ready mixed priming coat, both of approvedquality for new work : 20 mm dia nominal bore |
| 317 | Painting G.I. pipes and fittings with synthetic enamel white paintwith two coats over a ready mixed priming coat, both of approvedquality for new work : 25 mm dia nominal bore |
| 318 | Painting G.I. pipes and fittings with synthetic enamel white paintwith two coats over a ready mixed priming coat, both of approvedquality for new work : 32 mm dia nominal bore |
| 319 | Painting G.I. pipes and fittings with synthetic enamel white paintwith two coats over a ready mixed priming coat, both of approvedquality for new work : 40 mm dia nominal bore |
| 320 | Painting G.I. pipes and fittings with synthetic enamel white paintwith two coats over a ready mixed priming coat, both of approvedquality for new work : 50 mm dia nominal bore |
| 321 | Providing and fixing gun metal gate valve with wheel of approved quality. 20mm dia nominal bore |
| 322 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore |
| 323 | Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore |
| 324 | Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore |
| 325 | Providing and fixing gun metal gate valve with wheel of approved quality. 65mm dia nominal bore |
| 326 | Providing & fixing Brass Compact Pressure Reducing Valve of brass body with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 25 mm dia nominal bore . |
| 327 | Providing & fixing Brass Compact Pressure Reducing Valve of brass body with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 32 mm dia nominal bore . |
| 328 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 25mm dia. . |
| 329 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 40mm dia. . |
| 330 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 50mm dia. . |
| 331 | Providing and fixing motorised butterfly valve with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box etc. complete. 50mm dia. . |
| 332 | (C.)- INTERNAL ELECTRICAL WORKS |
| 333 | SUBHEAD I- WIRING POINTS |
| 334 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 335 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 336 | Wiring for light/ Power plug with 2X4 sq. mm FRLS PVC insuleted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 Nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 337 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire |
| 338 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire |
| 339 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire |
| 340 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 x 16 sq.mm. + 1 x 6 sq.mm. earth wire |
| 341 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 x 16 sq.mm. + 2 x 6 sq.mm. earth wire |
| 342 | Supply and wiring of 3 number 25 sq.mm. PVCinsulated 1100V grade single core Copper conductorcable in 50 mm dia heavy guage rigid steel conduit partlyconcealed in wall and partly laid in slab along withreinforcement before concreting, with two number 16sqmm single core Copper conductor calbe as earthcontinuity wire drawn in coudit including matchingcolour wash etc, complete in all respect. |
| 343 | Add for Invertor Wiring in wiring Point for light/ Fan/ Plugwith 1.5 mm Cu Wire |
| 344 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 345 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 5/6 amps switch |
| 346 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 2 Way 5/6 amps switch |
| 347 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 15/16 amp switch |
| 348 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 3 pin 5/6 amp socket outlet |
| 349 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 6 pin 15/16 amp socket outlet |
| 350 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 351 | Installation of exhaust fan in the existing opening , including making good the damage, connection, testing commissioning etc. as required. (a): Up to 450mm sweep |
| 352 | SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS |
| 353 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 354 | Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housingwith heat sink, diffuser/ Reflector and driver set complete in all respect. CAT AAA |
| 355 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. CAT AAA |
| 356 | Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect CAT AA |
| 357 | Supply & fixing of 7W Bulb etc suitable for both surface & surface complete in all respects. . Make: Bajaj/ Havells etc. |
| 358 | Supply and fixing of single unit LED aviationobstruction light complete with transformer and LEDspiral etc complete in all respect.. CAT AAA |
| 359 | Supply and fixing of Mirror Light 10 Watt LED . complete in all respect . Make: Wipro/ Havells etc. |
| 360 | SUBHEAD III-DISTIBUTION BOARD |
| 361 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way Double door (4 + 12) |
| 362 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door (4 + 18) |
| 363 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A FP MCB Triple pole and neutral |
| 364 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 16A DP MCB Double pole |
| 365 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 366 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve CAT A |
| 367 | S&F of 40 Amp. 4 pole MCB (10 KA) CAT A |
| 368 | S&F of 40 Amp. DP MCB (10 KA) C Curve CAT A |
| 369 | S&F of 63 Amp. DP MCB (10 KA) CAT A |
| 370 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 371 | SUBHEAD IV-CABLES |
| 372 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 25 sq. mm (28mm) |
| 373 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4 X 16 sq. mm (28mm) |
| 374 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4 X 10 sq. mm (25mm) |
| 375 | SUBHEAD V -MISCELLANEOUS |
| 376 | Supply of 250mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. Make : Hevells (Modle Trill Air DX) . |
| 377 | Supply of 450mm size PVC exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. Make : Hevells (Modle Turbo Force Neo) /Hindware etc |
| 378 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 379 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 380 | SUBHEAD VI-CABLE TRAY & RACEWAY |
| 381 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 382 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 750 mm width X 75 mm depth X 2.0 mm thickness |
| 383 | Supplying and installing 32 mm G.I Conduite . |
| 384 | Supplying and installing 40 mm G.I Conduite . |
| 385 | Supplying and installing 50 mm G.I Conduite . |
| 386 | SUBHEAD VII-LIGHTNING CONDUCTOR |
| 387 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30cm square C.I. frame with hinged cover & masonry housing.Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. |
| 388 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 389 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. |
| 390 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run) |
| 391 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run) |
| 392 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 393 | SUBHEAD VIII-PANELS |
| 394 | LT PANEL |
| 395 | Design, Supply, installation, testing and commissioning of indoor/outdoor floor mounted/ wall mounted, IP43/IP65, IEC 61439/IS 8623, factory built, modular, sectionalised, compartmentalized, extendable type HT/LT cubicle panel of suitable size suitable for operation on 33/11/0.433/0.415 kV, 50 Hz AC 3 phase supply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears as per SLD ,technical specifications etc.complete in all respect so as to fulfill all as required. . |
| 396 | The minimum clearances between bus bars shall be as follows : |
| 397 | Phase to phase - minimum 20mm |
| 398 | Phase to neutral-minimum 15mm |
| 399 | Incoming : |
| 400 | 1Nos 500 Amp. 4P MCCB of 36kA Breaking capacity |
| 401 | Metering : |
| 402 | 1 Set of CT's one of 500/ 5Amp ratio for Multifunction Meter |
| 403 | 1 Nos. Set of Phase Indication Lamp. |
| 404 | 1 Nos. of class-III Type SPD |
| 405 | Bus Bar : |
| 406 | 600 Amp.TPN aluminimum bus bar of suitable length.50KA |
| 407 | Outgoing : |
| 408 | Phase indication lamps on each outgoing to be provided. |
| 409 | 6 No.63 Amp 4P MCCB. (10 KA) |
| 410 | 4 No.63 Amp 2P MCB. (10 KA) |
| 411 | 55 No.40 Amp 2P MCB. (10 KA) |
| 412 | Panel described as above with 2 Years AMC & comprihensive warranty. . |
| 413 | Fire Panel |
| 414 | Incoming : |
| 415 | 01 No. 250 Amp 4P MCCB. (50 KA) |
| 416 | 01 No. 250 Amp 4P ATS |
| 417 | Metering : |
| 418 | 1 Set of CT's one of 250/ 5Amp ratio for Multifunction Meter |
| 419 | 1 Set of CT's one of 250/ 5Amp ratio 50/51 |
| 420 | 1 Nos. Set of Phase Indication Lamp. |
| 421 | 1 Nos. of class-III Type SPD |
| 422 | Bus Bar : |
| 423 | 1 Set of 300 Amps TP Aluminium Bus Bars |
| 424 | Outgoing : |
| 425 | Phase indication lamps on each outgoing to be provided. |
| 426 | 01 No.125 Amp TPN MCCB. (50 KA) |
| 427 | 02 No. 63 Amp TPN MCCB. (50 KA) |
| 428 | Panel described as above and with two years AMC & Comprihensive warranty. |
| 429 | Plumbing Panel |
| 430 | Incoming : |
| 431 | 01 No. 100 Amp 4P MCCB. (25 KA) |
| 432 | 01 No. 100 Amp 4P ATS |
| 433 | Metering : |
| 434 | 1 Set of CT's one of 100/ 5Amp ratio for Multifunction Meter |
| 435 | 1 Set of CT's one of 100/ 5Amp ratio 50/51 |
| 436 | 1 Nos. Set of Phase Indication Lamp. |
| 437 | 1 Nos. of class-III Type SPD |
| 438 | Bus Bar : |
| 439 | 1 Set of 200 Amps TP Aluminium Bus Bars |
| 440 | Outgoing : |
| 441 | Phase indication lamps on each outgoing to be provided. |
| 442 | 03 No.63 Amp 3P MCCB. (25 KA) |
| 443 | 02 No.40 Amp 3P MCCB. (25 KA) |
| 444 | 01 No. 25 Amp 3P MCCB. (25 KA) |
| 445 | 01 No.63 Amp DP MCB. (10 KA) |
| 446 | Starter As per Type 2 & Pump Rating |
| 447 | Panel described as above and with two years AMC & Comprihensive warranty. |
| 448 | (D)- FIRE FIGHTING & ALARM SYSTEM |
| 449 | Schedule Items |
| 450 | Manually Operated Fire Alarm System : |
| 451 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. |
| 452 | 10 Zone |
| 453 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 454 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 455 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 456 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 457 | Terrace Pump Set : |
| 458 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump |
| 459 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 460 | Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. |
| 461 | M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
| 462 | Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 463 | 900 lpm at 35 m Head |
| 464 | Pipes & Accessories : |
| 465 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 466 | 80 mm dia |
| 467 | 100 mm dia |
| 468 | Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 469 | Single headed Stainless steel |
| 470 | Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: |
| 471 | Single headed Stainless steel |
| 472 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 473 | 80 mm dia |
| 474 | 100 mm dia |
| 475 | Supplying, fixing, testing & commissioning of double flanged Sluice Valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : |
| 476 | 100 mm dia |
| 477 | Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 478 | Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 479 | 80 mm dia |
| 480 | 100 mm dia |
| 481 | Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 482 | 100 mm dia |
| 483 | Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 484 | Stainless Steel (Grade 304) |
| 485 | Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 486 | Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : |
| 487 | Stainless Steel (Grade 304) |
| 488 | Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : |
| 489 | 2 way - 100 mm dia M.S. Pipe |
| 490 | Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. |
| 491 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 492 | 3½ X 35 sq. mm (35mm) |
| 493 | Earthing Work : |
| 494 | Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/ coke and salt as required. |
| 495 | Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 496 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. |
| 497 | 100 mm dia |
| 498 | Non-Schedule Items |
| 499 | Fire Extinguishers : |
| 500 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 501 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 502 | Providing & Fixing of 1.6 mm thick M.S / Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making Recessed type mansoary box (by civil contractor). |
| 503 | 1500x900 mm (Indoor Cabinet) Only Frame |
| 504 | Providing & fixing cast iron Air Release Valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. |
| 505 | Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. |
| 506 | Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. |
| 507 | Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-15 Kg/cm2. |
| 508 | Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45°C temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :- |
| 509 | 100 mm dia |
| 510 | Control Panel (for Terrace Pumps) : |
| 511 | supplying, Installtion, testing and commissioning of Electrical Control Panel of cubicle construction, floor/wall mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalised with hinged locakable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection, having switchgears and access ories mounting and internal wiring, earth terminals numbering etc. complete in all respects, suitable Outlet Piping Stop Ball Cock, Drain Valve, Drain Pipe Air Check Valve protection class IP 42 as required.for terrace, Roof Cover over panel. |
| 512 | 63 Amp, 25kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 1 Set |
| 513 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 514 | 35 sq. mm 3-1/2 core |
| 515 | (B)- EXTERNAL DEVELOPMENT |
| 516 | (1)- RAINWATER HARVESTING |
| 517 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 518 | In all kind of soil upto 1.5m depth |
| 519 | In all kind of soil upto 1.5m to 3.0m. depth |
| 520 | In all kind of soil upto 3.0m to 4.5m. depth |
| 521 | In all kind of soil upto 4.5m to 6.0m. Depth |
| 522 | Providing and laying in position cement concrete of specified grade excluding the ccost of centering and shuttering -All work up to plinth level: |
| 523 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 524 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 525 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 526 | Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) |
| 527 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 528 | Mild steel and Medium Tnsile steel bars. |
| 529 | Centring and shuttering including struting , proping etc and removal of form for : |
| 530 | Suspended floors, roofs, landings, balconies and access platform. |
| 531 | 15mm cement plaster on rough side of single or half brick wall mix |
| 532 | 1:4 (1 cement : 4 coarse sand) |
| 533 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 534 | With 20x20mm square bar |
| 535 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 536 | M.D. -10- Circular shape 500mm internal diameter |
| 537 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. |
| 538 | Drilling of 300mm dia bore hole manually. |
| 539 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 540 | 150 mm nominal size dia |
| 541 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 542 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 543 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 544 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 545 | EXTERNAL PIPE NETWORK SYSTEM |
| 546 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, |
| 547 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 548 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 549 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 550 | 150mm diameter |
| 551 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 552 | 150mm diameter S.W. Pipe |
| 553 | Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix |
| 554 | (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 |
| 555 | (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. |
| 556 | a) Inside size 60x60 cm & 60 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. |
| 557 | (2)- CC ROAD |
| 558 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by engineer in charge. All kinds of soil 0 to 0.30 m |
| 559 | Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. |
| 560 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 561 | Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 562 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. |
| 563 | Providing and fixing in position pre-moulded joint filler in expansion joints. |
| 564 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. |
| 565 | (3)- BORING & TUBE WELL |
| 566 | Boring/drilling bore well of required dia for casing/ strainer pipa, by suitable method prescribed in IS: 2800 (part I), Including collIecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plents & machineries required for the job, all complete as per direction of Engineer -in charge, upto 90 metre depth below ground leval. |
| 567 | ALL TYPE OF SOIL |
| 568 | 350 mm dia |
| 569 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IG: 2800 (part I), including collecting sample from differeht streta, preparing and submitting strata chart/ bore log. including hire & running charges of all equipments, toots, plants & machineries required for the job, all complete as per direction of Engineer -in- charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 570 | Rocky strata lnciuding Boulders |
| 571 | 350 mm dia |
| 572 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Résistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of raquired dia, conformlng to IS: 4270, of reputed & approved make, lnduding painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. |
| 573 | 150 mm nominal size dia having minimum wall thickness 5.00 mm |
| 574 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Rasistance FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pips (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, induding painted with outside surface with two coats of anticorrosive bitumestic paint of approvad brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for alt deptha, as per direction of Engineer -in-charge. |
| 575 | 200 mm nominal size dia |
| 576 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit over the existing Iayer of boulders, in required thickness, for all leads & Iifts, all compete as per direction of Engineer-in-charge. |
| 577 | Around Pipe(3.14*0.15*0.15*90.00) |
| 578 | Gravel packing in tubewsll construction in accordance with IS: 4097, including providing gravel fine/ medium/ .coarse, in required grading. & sizes. as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 579 | (3.14*1.50*1..50*0.20) |
| 580 | Development of tube well in accordance with IS : 280D (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limît), with required capacity air compressor, running the compressor for required time. tifl well ïs fully developed, measuring yield of well by 'V* notch method or any other approved method, measuńng static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of aİr compressor, tools & accessories etc., .all as per requirement and direction of Engineer-in-charge. |
| 581 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable ae per requirement, all complete for bore well of. |
| 582 | 15ü mm dia |
| 583 | Providing and fixing M.S. clamp of required dia to the top of casings housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. |
| 584 | 1õß mm.dia |
| 585 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe.assembly of tube well as per IS:2800 (part I). |
| 586 | 150 mm dia |
| 587 | Providing and fixing G.I. pipes complete with G.I. fittings induding trenching and refilling etc. |
| 588 | 80 mm dia nominal bore |
| 589 | Supplying and drawing following sizes.of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steël/ PVC conduit as required. 10 x 4 sq. mm |
| 590 | Supply of Submersibule pump with control panel, support wire etč. complete 2.0 H.P. (KSB / EQ.) |
| 591 | (4)- SEPTIC TANK & SOAK PIT |
| 592 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. DSR-2.8.1 |
| 593 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 594 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 595 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement 12 mm cement plaster |
| 596 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 597 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slabs |
| 598 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (Plinth Beam) |
| 599 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 600 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 601 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 602 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 603 | Providing and fixing 150 mm S.C.I. tee at the inlet and outlet of septic tank. |
| 604 | Providing & fixing 75mm dia vent pipes. |
| 605 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 606 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 607 | M.D. -10- Circular shape 500mm internal diameter |
| 608 | L.D. -2.5- Circular shape 450mm internal diameter |
| 609 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 610 | With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 611 | (5)- DRAIN |
| 612 | Earth in excavation |
| 613 | P.C.C. in foundation (1 : 4: 8 ) |
| 614 | P.C.C. in foundation in 1:2:4 |
| 615 | Plaster 15mm |
| 616 | Brick work in 1:4 |
| 617 | BOUGHT OUT ITEMS |
| 618 | (6)- Passengers Lift (8 Nos.) |
| 619 | Supplying, Installation ,Testing & Commissioning of 8 Passenger/ Bed Elevators, 544 Kg, With AC ,VVVF drive,stainless steel door, and automatic power operated doors, ARD, with standard controls and operating divices for G+8 Floors. Travel distance / Stops (Mtrs) 38m approx /9 Stops /9 Opening, 1.5 mps speed Including Lift License, and machine room, Free service for one year all Complete in all respect. |
| 620 | (7)- DG SET (100 KVA) |
| 621 | GST Extra as applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail