| 1 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). |
| 3 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 4 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level.1 : 1.5:3 (1 cement :1.5 course sand (zone-III): 43graded stone aggregate 20 mmnominal size. |
| 6 | Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 7 | Providing designation 75 B brick work in C.M.(1 :6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 8 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15̊ landigs, balconis, shelves, chajja, lintels, bands, plain window sills stair cases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinfocement, with 1:1.5:3 (zone-III): 3 gradedstone agggregate 20 nominal size). |
| 10 | Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 11 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 13 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 14 | supplying, fitting and fixing 250X20X6mm L-type M.S clamp properly fishtailed, including maiking holes and setting as same in 250X125X75mm. Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I. |
| 15 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 16 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 17 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 18 | Supplying, fitting and fixing 30 mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 19 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 20 | Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19 mm thick (1:2:4) with 12 mm to 6mm size graded stone chips and top layer 6 mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l |
| 21 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 22 | Providing 12mm. cement plaster (1:3) with punning with clean coarse sand of F.M. 1.5 including cost of carriage, screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. |
| 23 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 24 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 25 | Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 26 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 27 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I |
| 28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 29 | Making holes in wall for laying H.C.L. pipe and restoring the same after pipe laying as per specification and direction of E/I. (ii) 250 mm dia |
| 30 | Supplying,fitting and fixing 40mmdia G.I. Pipe fitted and fixed in floor outlet to drain out water, in cement concrete including cutting hole,making good the wall and finishing,all complete as per building specificationand direction of E/I. |
| 31 | Centring and shuttering including struting, propping etc and removal of form work for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 32 | Centring and shuttering including struting, propping etc and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 33 | Centring and shuttering including struting, propping etc and removal of form work for Suspended floors ,roofs, landing ,balconies and access platform |
| 34 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) 40 % |
| 35 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) 30 % |
| 36 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) 30 % |
| 37 | CARRAIGE OF MATERIALS (a)Sand with av. Lead of 1 K+51P) km |
| 38 | (b)s/chips with av. Lead of 1k+9p) km |
| 39 | (d) Bricks - 8km (1k + 7p) |
| 40 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 41 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 42 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 43 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement: 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 44 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 45 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 46 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 47 | Supplying, fitting and fixing vitreous white glazed earthenware I.W.C of Parry, Hindustan or any other I.S.S approved make with 100 mm H.C.I 'P' trap, 15 litres (high level) C.I pull and let go flushings cistern-1 12.5 liter low down C.I mosquito Proof flushing cistern of Nomus or other I.S.S equivalent make, Complete with all fittings, C.I or R.S bracket, 32 mm alkathene/ P.V.C telescopic flush pipe about 2 meter long with one brass coupling and clamps. C.I chain and pull including supplying and fixing a pair of vitreous white glazed earthen ware foot rest to be fixed in floor 15 mm C.I body brass spindle stop cock of weight not less than 50 gms, 15mm P.V.C connection pipe 450 mm long and than 15 mm P.V.C connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I (A)580mm long With 12.5 litre low level P.V.C. cistern |
| 48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion (i) Single socketed pipes 110 mm dia |
| 49 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 50 | CARRAIGE OF MATERIALS (a)Sand with av. Lead of 1 K+51P) km |
| 51 | (b)s/chips with av. Lead of 1k+9p) km |
| 52 | (c) Bricks - 8km (1k + 7p) |
| 53 | Point wiring in PVC conduit, with piano type swtich:- Wiring for point /fan point /exhaust fan point /call point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch ,phenolic laminated sheet, suitable size PVC/G.I. box etc.as .Group-B |
| 54 | Circuit/submain wiring in PVC conduit:- Wiring for circuit/submain wiring along with earth with following sizeg PVCinsulated copper conductor,single core cable in surface/recessed PVC conduit as requied. 2x2.5sq.mm+1x2.5sq.mm earth wire |
| 55 | 2x4 sq.mm+1x4.5sq.mm earth wire |
| 56 | S/F Piano type switch/socket:- Supplying and fixing following piano type switch/sockit on the existing switch box/cover including connections etc as required. |
| 57 | S/F power plug point with pinao type accessories :-supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin 15/16 mps socket outlet and 15/16 mps piano type switch connection, painting etc. us rquoired. |
| 58 | S/F ceiling rose:- suppliying and fixing 2 pin mps. Ceiling roase on the existing juction box/woon bolck including connection etc. as required |
| 59 | S/F batten holder:- supplying and fixing batten/ angle holder incuding connection etc as required. |
| 60 | Supplying and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse unit in existing metal board with rewirecable type fuses, including drilling holes in metal board, making connections, etc as required. 32 amps, double pole |
| 61 | Supply of 48\\"(1200 mm)AC ceiling fan |
| 62 | 15/18 W LED Bulb |
| 63 | Add cost of S/B and Wall Writing |
| 64 | add 18 % GST |
| 65 | add 1 % labour cess Please Enable Macros to View BoQ information |