| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 2 | Group C |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 4 sq. mm |
| 6 | 6 x 6 sq. mm |
| 7 | Supply and fixing of 32 x 20 mm DLP mini- trunking white-system with independent cover etc. as required complete. |
| 8 | Supply and fixing of following accessories suitable for 32 mm x 20 mm size plastic trunking white system. |
| 9 | End cap |
| 10 | internal / external angle |
| 11 | changeable flat angle |
| 12 | flat junction |
| 13 | Supply and fixing of 105 x 50 mm DLP trunking white-system but without cover and partition etc. as required complete. |
| 14 | Supply and fixing of following accessories suitable for 105 mm x 50 mm size plastic trunking white system. |
| 15 | 85 mm flexible cover |
| 16 | End cap |
| 17 | Internal angles- adjustable from 80°-100° |
| 18 | external angles- adjustable from 60°-120° |
| 19 | flat junction |
| 20 | flat angles |
| 21 | separation partitions |
| 22 | Joints for 85mm width cover |
| 23 | base joints |
| 24 | S & F following size of steel flexible pipe along with the accessories on surface etc as required |
| 25 | 20 mm |
| 26 | 25 mm |
| 27 | Supply and fixing of following LED light fixture with efficiency >100 lumen/ watt, P.F. >0.95, THD<10%, Electronic driver, LED lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete. |
| 28 | 1 X 20W Box type LED tube with fitting |
| 29 | 36 watt recess mounting LED light fixture 600 x 600 mm |
| 30 | 36 watt surface mounting LED light fixture 300 x 1200 mm |
| 31 | Supplying, installation of Clip-on frame with finishing plate for 85mm cover for DLP plastic trunking 105mm x 50mm etc. as reqd. |
| 32 | 3 module |
| 33 | 6 module |
| 34 | Supplying and fixing following modular switch/ socket on the existing clip-on frame fixed on 85mm cover of 105 x 50 mm DLP plastic trunking including connections etc. as required complete. |
| 35 | 6 A switch |
| 36 | 20 A switch |
| 37 | 6 A pin 2/3 pin socket outlet |
| 38 | 6/16 A 3 pin socket outlet |
| 39 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 40 | 5/6 A switch |
| 41 | 15/16 A switch |
| 42 | 3 pin 5/6 A socket outlet |
| 43 | 6 pin 15/16 A socket outlet |
| 44 | Blanking Plate |
| 45 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 46 | 3 Module |
| 47 | 6 Module |
| 48 | Supplying and fixing following size/ modules, plastic box for modular switches in recess etc as required. |
| 49 | 3 Module |
| 50 | 6 Module |
| 51 | Supply and installation of 400mm sweep AC 230/250 volts, 50 Hz wall mounting revolving fan with brackets etc complete. |
| 52 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 53 | Dismantling and refixing of pole fuse box/ changeover switch/ main switch/ contactor/MCCB/ DB kWH meter etc. as required complete. |
| 54 | Dismantling, disconnecting old damaged unserviceable fl fitting/ exhaust fan/ ceiling fan/ bulkhead fitting with bracket etc. as reqd. and depositing in sectional store. |
| 55 | Dismantling concealed & damaged DB/TPN Switches/starter/ loose wire boxes along with all accessories and depositing the same in the sectional store repairing the damages as reqd complete. |
| 56 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 57 | 20 mm |
| 58 | 25 mm |
| 59 | Laying of 1/2/3 run of UTP cable enhanced cat 5/cat 6 cable in existing steel conduit pipe/GI pipe/ raceway / RCC pipe as reqd. the cost shall also include numbering of networking wire from room to rack as reqd. (wire will be supplied by dept) |
| 60 | Fixing of RJ-45 modular box with cover plate or I/o box for internet on surface/ recessed cutting the wall making good the same as required. ( box and cover plate will be supplied by dept.) |
| 61 | Supply & Laying of 32 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete. |
| 62 | in ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 63 | On Surface |
| 64 | S&F, Copper tube / reducer/ lug terminals suitable for following size of conductor. |
| 65 | 6 /10/16 Sq.mm. Please Enable Macros to View BoQ information |