| 1 | BUILDING PORTION |
| 2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 3 | Providing and laying in foundations and plinth cement concrete 1 : 3: 6 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 4 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 5 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 6 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 7 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 8 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 10 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete. |
| 11 | c)Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 12 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 13 | e) Column, pillars, posts and struts etc. |
| 14 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks |
| 15 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/ TMT steel |
| 16 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 17 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 18 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 19 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.a) 38 mm thick best available local wood, class - B I |
| 20 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill. |
| 21 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.b) 250 x 10 mm |
| 22 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm |
| 23 | 25 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement. |
| 24 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 25 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 26 | Finishing walls with Acrylic Smooth exterior paint of required shade : (a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 27 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 28 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 29 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 30 | Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand). |
| 31 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 :6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cmthick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cementmortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 32 | Tile works |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., completeD) Size of Tile 1000x1000 mm |
| 34 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 35 | WATER PROOFING |
| 36 | Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45, 1.20 & 1.70 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-2 grade-I (fibre base self finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete |
| 37 | Grading roof for water proofing treatment withc) Cement mortar 1 : 3 (1 cement : 3 coarse sand). |
| 38 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard designa) 100 mm dia SW pipes |
| 39 | Providing and fixing MS fan clamps of standard shape and size in existing RCC slab including cutting chase and making good and painting exposed portion of the clamps compl |
| 40 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in foot path,parks,lawns,drive ways or light traffic parking etc,of required strength, thickness & size/ shape,made by table vibratory method using PU mould, laidin required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. |
| 41 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required.d) Range of four urinals with 15 Litre CI automatic flushing cistern |
| 42 | Providing and fixing Water Tank (plastic type) & Including necessary fittings |
| 43 | Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.(a) 8mm thick (mirror polished and machine cut edge) |
| 44 | Providing and fixing aluminum Tower bolts anodizedor transparent or dyed to required color or shade with necessary screws etc complete.a) 300 x 10 mm |
| 45 | Providing and fixing aluminum Handle sanodised transparent or dyedto required color or shade with necessary screws etc complete. a) 125 mm |
| 46 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 47 | Exterior and Interior decoration of the building |
| 48 | Add carriage charge |
| 49 | Civil external service connection charge |
| 50 | Internal electrical installation charge |
| 51 | Internal water supply charge |
| 52 | SH:- C/o Septic Tank |
| 53 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 54 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 55 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : |
| 56 | a) Foundations and plinth |
| 57 | Brick work with best available local bricks in foundations and plinth in cement mortar1:4 (1 cement : 4 fine sand). |
| 58 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand |
| 59 | Neat cement punning. |
| 60 | Centring and shuttering including strutting, propping etc and removal of form work for :c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 61 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 62 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Mild steel |
| 63 | Providing and fixing on wall face as best os cement soil, waste and vent pipes including jointing with spunyarn soaked in bitumen and cement mortar 1:2 (1cement :2coarse sand) complete |
| 64 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design |
| 65 | Add Carriage charge Please Enable Macros to View BoQ information |