| 1 | Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed. |
| 2 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and as directed. |
| 3 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and as directed. Note: To be executed for provision of ridges and hips. |
| 4 | S&F 1.25mm thick and 150mm dia mild steel sheet eaves gutter half round with rounded edges, galvanized class 3, coloured preprinted matching the colour to extra roof sheet with necessary brackets complete all as specified and as directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 6 | Dismantling timber scantling 40Sqcm and over in section as in unframed work in any position complete all as specified and as directed. |
| 7 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (GdeE- 250) quality A complete all as specified and as directed. |
| 8 | S&F rolled mild steel plates (plain or chequered) square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment GDE Fe410-W (GdeE- 250) quality 'A' complete all as specified and as directed. |
| 9 | M&L for mild steel flat iron in bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 10 | S&F mild steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and as directed. |
| 11 | S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed. |
| 12 | M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer complete all as specified and as directed. |
| 13 | S & F 4mm thick High Pressure steam Crude Non Asbestos Fiber Cement plain Board (E-Board Classic) of size 605mm x 605mm with Anodised aluminium snap grid frame work for false ceiling, flat or sloping fixed or laid/ inserted to timber/GI/Aluminium framework with screws and hangers 6 mm dia GI (n.exc 1200 mm in length apart) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long including dismantling of old ceiling of any description complete all as specified and as directed. |
| 14 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as directed. |
| 15 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in sub base/plinth protection complete all as specified and directed. |
| 16 | M & L for 100 mm thick PCC 1:2:4, type B2 (using 40 mm graded crushed stone aggregates) as in path / paving / hard standing / floor and finished the surface even and fair without using extra cement complete all as specified and as directed. |
| 17 | M & L for 25mm thick PCC 1:2:4, type B0 using (12.5 mm graded crushed stone aggregate) as in floors to receive tiles complete all as specified and as directed. |
| 18 | M&L for cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre including non circular Synthetic Fiber @ 0.25% by weight of cement or as per manufacturer instruction, thickness of concrete 25 cm or more complete all as specified and as directed.NOTE : Synthetic Fiber Shall be measured and paid separately. |
| 19 | Supply only Polyester triangular fibres as secondary reinforcement in all types of concrete and mortars. |
| 20 | Supply only high performance water reducing super plasticising admixture (fosroc conplast SP-500 or equivalent to IWL/Sika/IWP/Pidilite) for producing pumpable concrete of high grade strength low permeability high early strength improve workability, dense and close textured concrete with reduced porosity and high cohesion for reducing risk of segregation and bleeding complete all as specified and as directed. |
| 21 | Finishing surface of concrete pavement by belting and finally brooming when concrete still remains green complete all as specified and as directed. |
| 22 | M & L for Forming 12mm thick expansion joints filled with pre-formed polyurethane joint filler (fosroc hydrocell XL or Equivalent) and top 30mm primed (Fosroc primer 7E of equivalent) and sealed with sealing compound, Grade \\"A' (Fosroc Thioflex 555 or equivalent) for concrete pavement 250mm complete all as specified and as directed. |
| 23 | M & L for forming contraction (dummy) joints 65mm deep x10mm wide, sealed with sealing compound Grade 'A' (Fosroc Thioflex 555 or equivalent) Before priming the surface complete all as specified and as directed. |
| 24 | M & L for forming Construction joint 30mm deep x10mm wide, sealed with polyurethane sealant (Fosroc Thioflex 555 or equivalent) complete all as specified and as directed. |
| 25 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for all as specified and as directed. |
| 26 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in beams, cantilever, lintels over 1.5 m span complete all as specified and as directed. |
| 27 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 28 | M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 29 | M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 30 | Use and waste formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels over 1.5m clear span, cantilevers, shelves including supports overhangs etc also splays between floors and beams for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 31 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja, floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 32 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 33 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 34 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 35 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 36 | M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 37 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 200Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 38 | M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 39 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 40 | Complete removal of existing treatment & levelling of wall/ceiling surface existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface complete all as specified and as directed. |
| 41 | M&L for preparation of new plastered surfaces of wall and ceiling and applying two or more coats of acrylic distemper 1st quality (ready mixed) having VOC content less than 50 gms/ltrs of required shade and colour complete as per manufacturer's specification over a coat of 1mm(average) thick wall care putty complete all as specified and directed. |
| 42 | M & L for preparation of newly plastered surfaces of walls and applying Two or more coats of 100% Premium exterior acrylic emulsion paint of required shade, having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all specified and as directed. |
| 43 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 44 | Taking down all existing roof treatment and demolition of cement concrete padding/levelling course (any thickness as available in site) including wire brushing and cleaning loose dust etc from surfaces of RCC roof including flashing and junction of parapet complete all as specified and as directed. |
| 45 | M&L for 25mm thick PCC 1:2:4, type B0 (using 12.5mm size graded crushed stone aggregate) as levelling course, padding on chajjas, etc including angular moulding at junction upto 10cm height mixed with WPC as per manufacturer's instruction, applied over prepared surfaces complete all as specified and directed.Note : (i) WPC shall be measured and paid separately as supply only.(ii) PCC shall be laid to achieve true slope towards the drain/weep holes. |
| 46 | M&L for applying a coat of Nano technology based water proofing compound (1 part powder: 1 part liquid), of desired consistency with nylon brush @ 5 sqm/kg coverage over vertical/horizontal surface of RCC roof and parapet complete all as specified and as directed. |
| 47 | M&L for applying Nanotechnology based Anti-corrosive with high strength carbon Fiber based shorter chain Epoxy coating (Bond Coat) of finest quality, high strength, high penetration, durable, UV resistant, high scratch/ impact resistant, bacteria resistant and thermally stable, Semi transparent, mixed in proportion (4 Base : 1 Hardner) in required consistency @ 8 sqm/kg over the entire prepared surfaces of roof/parapet/sunken floor complete all as specified and as directed.Note: 1. Rate shall include for making surface clean, dust free, dry, and free of wax, grease, oil, loose or peeling particle, and other foreign materials.2. During application ambient temperature is preferred. Frost, fog, or damp conditions should be avoided. |
| 48 | M&L for applying two coats of Nanotechnology based water-based one pack epoxy based Nano barrier coat, durable, highly water repellent, UV resistant, fungus/ algae/ bacteria resistant, thermally insulating and elastomeric including high capillary pressure resistance, anti-bacterial, low VOC, UV resistance, high coverage area @ 6.5 sqm/kg in each coat complete all as specified and as directed. Note : 1. Rate shall include for making surface clean, dust free, dry, and free of wax, grease, oil, loose or peeling particle, and other foreign materials.2. During application ambient temperature is preferred. Frost, fog, or damp conditions should be avoided. |
| 49 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm complete all as specified and as directed.Note - Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces |
| 50 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and as directed. Note - Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces. Please Enable Macros to View BoQ information |
| 51 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and as directed. Note - Rate shall be deemed to be include for cutting holes/demolition of masonry walls etc for taking down chowkhats and making good the damaged surfaces. Please Enable Macros to View BoQ information |