| 1 | Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 3 | M & L for 25mm thick PCC 1:2:4, type B0 using (12.5 mm graded crushed stone aggregate) as in floors to receive tiles complete all as specified and as directed. |
| 4 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 5 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 6 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 7 | M & L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 8 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 200Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 9 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 10 | Complete removal of existing treatment & levelling of wall/ceiling surface using MECHANICAL / ELECTRICAL OPERATED SANDING / SCRAPING MACHINE WITH INBUILT VACCUM SUCTION system to suck the existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface complete all as specified and as directed. |
| 11 | M&L for preparation of old/new plastered surfaces and applying a coat of 1mm (average thick) white putty of new/old plaster, and applying two or more coats Distempering 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ltrs of approved manufacturer, of required shade and colour complete as per manufacturer's specification complete all as specified and directed. |
| 12 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces using Airless Paint Primer Sprayer using smart technique, on newly plastered surface of wall, cornices complete all as specified and as directed . |
| 13 | Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from frame) complete all as specified and directed. |
| 14 | Taking down chowkats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm complete all as specified and directed. Please Enable Macros to View BoQ information |
| 15 | Taking down chowkats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm complete all as specified and directed. Please Enable Macros to View BoQ information |