| 1 | Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retardant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retardant type) Make-Schneider(Zencelo)/ legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group-A. |
| 2 | Group-B. |
| 3 | Group-C. |
| 4 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retardant type)) with suitable size modular box & cover( falme retardant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider (Zencelo) / legrand( Myrius) /Panasonic (vision) |
| 5 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( flame retardant type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 6 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retardant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision) |
| 7 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/ Precision/ Norpack/Anchor/Kinjal as required as per direction of Engg.-in-Charge. a) 2x1.5mm2 + 1x1.5mm2 |
| 8 | b) 2x2.5mm2 + 1x1.5mm2 |
| 9 | c) 2x4mm2 + 1x1.5mm2 |
| 10 | d) 2x10mm2 + 1x4mm2 |
| 11 | e) 4x16mm2 + 2x10mm2 |
| 12 | Supply and fixing of Modular switch ,Socket , T.V Socket and Telephone socket etc. Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision) 6Amp/10Amp switch (Modular type ) |
| 13 | 6Amp/10Amp socket( Modular type) |
| 14 | 16Amp/20Amp switch (Modular type ) |
| 15 | 16Amp/20Amp socket.(Modular type ) |
| 16 | S/F of 32A Modular DP Switch with Modular GI Box and Cover Plate.Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision) |
| 17 | S/F of 20A Modular DP Switch with Modular GI Box and Cover Plate.Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision) |
| 18 | DBsSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 19 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 20 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB .Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.The MCB should be Replacement Warranty will be 1 year. |
| 21 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,DP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.The MCB should be Replacement Warranty will be 1 year. |
| 22 | Supplying and fixing 40Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year. |
| 23 | Supplying and fixing 40Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year. |
| 24 | S/F of 65KA 4P Type 1+2 SPD. Legrand /Siemens /Schneider/ ABB/OBO/Dehn |
| 25 | Fitting & FixturesSupplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) |
| 26 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 27 | S/F of Street light- 90W,120 lm/w efficacy ,IK 08 new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/ Bajaj) (5Years Warranty) |
| 28 | S/F of Street light- 120W,120 lm/w efficacy ,IK 08 new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/ Bajaj) (5Years Warranty) |
| 29 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 30 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) .The luminaire should be Replacement Warranty will be 2 years |
| 31 | Supply & Fixing of 80 Watt High Bay Light .Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj |
| 32 | S/F of Geyser 15 ltr capacity. make :Havells/Jaquar/Bajaj/AO Smith/V-Guard |
| 33 | AIR CONDITIONINGSupply , installation, testing and commisioning of 1.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/ Mitsubishi/ Hitachi/Carrier/LG) |
| 34 | Supply, , installation, testing and commisioning of 2.0 TR high wall 5 star inverter type split A.C machine (BTU/Hr-21000-24000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/ Mitsubishi/ Hitachi/Carrier/LG) |
| 35 | S/F of 5KVA Voltage stabilizer (90V - 300V) ISI Marked. (Make:- V-Guard/MICRO-TEK). |
| 36 | Supply,installation of hard/soft copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 37 | Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.25mm nom. Dia pipe |
| 38 | Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C |
| 39 | Repair & Maintenance of Existing AC MachinesPartial Gas Charging to 1.5/2 TR Split AC Units(a)R-410 Gas |
| 40 | (b)R-32 Gas |
| 41 | Full Gas Charging to 1.5/2 TR Split AC Units |
| 42 | Servicing Charges of AC Machines |
| 43 | S/F of Outdoor unit Fan Motor of 1.5 TR AC |
| 44 | S/F of Condenser of Outdoor unit of 1.5 TR AC |
| 45 | S/F of Condenser of Outdoor unit of 2.0 TR AC |
| 46 | S/F of PCB of Indoor unit |
| 47 | S/F of Compressor of Outdoor unit of 1.5 TR AC |
| 48 | S/F of 50 MFD Capacitor unit |
| 49 | UPSSupply ,installation ,testing & commissioning of 20KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 60 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 120AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/ APC/Vertiv) ) as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. |
| 50 | UPS PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed in the incomer In commer- 01 number of 63 Amps 4P Onload Changeover with Ics=100% Icu.Busbar- 04 numbers of 100 Amps Electrolytic Aluminum busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator Out going- (i) 40A 4P MCB, C series, 10kA- 02 Nos. (ii) 40A DP MCB C series, 10kA-06 Nos. Instrument- (i) 03 numbers phase indicating lamp with HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication (iii) 01 set of 40KA TYPE 2 4P SPD along with 63A 4P MCB.Make of MCCB-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD- Legrand/ Siemens/ Schneider/ ABB/ OBO/Dehn |
| 51 | Area LightingSITC of 12M high mast shaft in two sections suitable for 50 m/sec wind speed along with headframe, luminaires carriage suitable for 06 luminaires in symmetrical arrangement and other accessories manufactured in factory with raising lowering system comprising double drum winch , 5mm diameter SS wire rope, trailing cable,connector,integral power tool motor, manual handle, junction box,lightning finial, LED floodlight luminaries of high efficacy 200W (06 Nos.) lumen with secondary optics as per desired lighting design, LED type single dome aviation obstruction light including construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at siteas10T/sqmtr at 2 metre depth with all materials and labour |
| 52 | Outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch,25A TP contactor for the automatic switching of luminaries,power tool control with 2 no 9A contactors and raise lower push button, Incoming 35sq.mm and out going 16 & 2.5 sq. mm terminals |
| 53 | SITC of 4 meter long aesthetically designed Flat lighting pole with 60W LED Post Top made up of Extruded aluminium with Spun Aluminium Top and Translucent Acrylic diffuser. Pole shall made up of Mild Steel Body and coated with zinc rich primer & pure polyester powder coating of Graphite grey colour. Bottom dia of the pole will be Ø139mm, Top dia Ø76mm. The Pole shall have base Plate □200x12mm thick with founation bolt. Pole is Compatible for Ø70mm size for cable entry & exist. Junction Box service door is made up cast aluminium and the control gear tray only is prewired with 2.5sq mm cable, 6A SP MCB and 32A 4pole terminal connector for loop-in loo-out arrangement with all materials & labour as required as per the direction of Engineer-in- Charge. The final design shall be approved by concerned client and Engineer-in-charge including civil foundation (Make: K -lite Flat Series Pole KP-4792 + KL-5040/Jaquar/ Philips/Panasonic/ Wipro/ Crompton /Bajaj/Havells/LT) |
| 54 | FIRE EXTINGUISHERSSupply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Genefire/Stat-x/Equivalent |
| 55 | Providing and Fixing of Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.Make-Safex/Fireshield/Ceasefire |
| 56 | Providing fire bucket ( fabricated from 20 SWG MS sheet ) filled with sand complete including painting with white colour inside & Red out side and Letter \\"FIRE\\" in black out side as approved by Engineer-in Charge with all contractors material, labour, transportation, lead & lift etc. complete including cost of incidental charges for successful completion of work as per specifications and as directed by Engineer-in-charge. at site. |
| 57 | Fire bucket stand fabricated by MS angles to install 3 Nos. of buckets. |
| 58 | CABLESupplying,fixing of perforated cable trays with horizontal & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 59 | Supply of 10 sq.mm 4 core XLPE Al Armoured Cable of ISI marked.(Make -Polycab/Havells /KEI/RR Kable/ Finolex/ Gloster) |
| 60 | Supply of 4 sq.mm 2 core XLPE Cu.Armoured Cable of ISI marked.(Make -Polycab/Havells /KEI/RR Kable/ Finolex/ Gloster) |
| 61 | Supply of 1.5 sq.mm 3 core XLPE Cu.Unarmoured Control Cable of ISI marked.(Make -Polycab/Havells /KEI/RR Kable/Finolex/Gloster) |
| 62 | Supply of 32 mm dia HDPE Pipe . |
| 63 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
| 64 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. |
| 65 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. (4C x 10 sq.mm) |
| 66 | Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (With charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 67 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Tapping from 50mm x 6 mm bus bar to all sub panel |
| 68 | Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate. |
| 69 | Supply and installation of Rubber Mats 8 mm thick |
| 70 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 71 | Identification signage for substation lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm. |
| 72 | S/F of Danger Board. Please Enable Macros to View BoQ information |