| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE WELLINGTON NAME OF WORK: SPECIAL REPAIRS TO OTM BLDG NO. WL-06 AT DSC CENTRE, KANNUR UNDER GE (ARMY) TRIVANDRUM Contract No: CWE/ WEL/ OF 2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Item of Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency Rate in Figures to be entered by the Bidder including all Taxes etc.Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category Total amount TOTAL AMOUNT With Taxes Total amount in words |
| 2 | Dismantling Single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed |
| 3 | Dismantling Battens for tiles, shingles etc, of any size including tilting fillets, spaced exc 15cm complete all as specified and directed |
| 4 | Dismantling timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and directed. |
| 5 | M & L for second class hardwood, scantlings, clean sawn, in framed work and fixed but except timber complete all as specified and directed. (Note: Old serviceable timber as obtained from dismantling above shall be re-used at site) |
| 6 | S & F MS steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed. |
| 7 | M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-B as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 8 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 9 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. |
| 10 | S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. |
| 11 | M & L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with one coat of creosote oil complete all as specified and directed. |
| 12 | M & L for aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering complete all as specified and directed. |
| 13 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 14 | S & F aluminium Anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed by the Engr-in-Charge. |
| 15 | S & F 4 mm thick, Non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified and directed. |
| 16 | M & L for preparing new surfaces of ceiling, etc and applying two coats of distemper oil emulsion over a coat of chalk whitening complete all as specified and directed. |
| 17 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 18 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) complete all as directed by the Engr-in-Charge |
| 19 | M & L for 20 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed. |
| 20 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, including 20 mm thick screed bed in cement mortor 1:4 complete all as specified and directed. |
| 21 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, as in vertical surfaces as in skirting, dado etc, and including 10 mm thick screed bed in cement mortor 1:3 complete all as specified and directed. |
| 22 | Demoltion of Brickwork or stone/boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing the debries outside the MD land complete all as directed by the Engr-in-Charge. |
| 23 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 24 | M & L for rendering 5mm thick in cement mortar 1:4, mixed with integral water proofing compound with weight of cement as per manufacturer's instructions over 10 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 25 | M & L for rendering 15 mm thick on stone masonry or other than fair faces of brick work surfaces in cement mortar 1:6 complete all as specified and directed. |
| 26 | Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 27 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 28 | Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed. |
| 29 | S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. |
| 30 | S & F 35 mm thick, factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed |
| 31 | S & F 35 mm thick, factory made, glazed/skeleton shutters with first class hard wood, open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I complete all as specified and directed |
| 32 | M & L for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:4 complete all as specified and directed. |
| 33 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 34 | M & L for Cutting holes in brick walls exc half brick but n.exc one brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement oncrete 1:2:4 Type B-1 as required complete all as specified and directed. |
| 35 | M & L for Mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 36 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed. |
| 37 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators ncluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene asket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed. |
| 38 | Providing and fixing Powder coated Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge complete all as specified and directed. |
| 39 | S & F 4 mm thick, sheet glass, ordinary quality and glazing with oil putty (or beading) in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 40 | S & F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed. |
| 41 | S & F 300mm long, Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 42 | S & F 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 43 | S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 44 | S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 45 | M & L for preparation new external surfaces of wall etc and applying Two coats of water based 100% Premium acrylic smooth exterior emulsion paint with silicon aditive and colour stay technology, excellent Dirt Pick up resistance with low VOC less than 50 gm/litre as per the LEEDS specifications and UV resistance as per IS 15489:2004, Alkali & fungal resistance of required shade (Company Depot Tinted) @ 1.43 Ltr (undiluted)/10 Sqm per two coat diluted with water as per manufacturer instructions over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over over 1mm thick external wall care putty complete all as specified and directed. (Note: Work shall be carried through an authorised applicator of the manufacturer's) |
| 46 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of wall primer and over 2mm thick of wall care putty to a smooth surface complete all as specified and directed. (Note: Work shall be carried through an authorised applicator of the manufacturer's) |
| 47 | Material and labour for complete removal of existing treatment from old decorated plastered surfaces of wall and preparation of new surfaces and applying two coats of distemper oil emulsion over a coat of wall primer (water thinnable/solvant thinnable) over 2mm thick wall care putty to a smooth surface complete all as specified and directed. (Note: Work shall be carried through an authorised applicator of the manufacturer's) |
| 48 | M & L for preparation new external surfaces of wall etc and applying Two coats of water based 100% Premium acrylic smooth exterior emulsion paint with silicon aditive and colour stay technology, excellent Dirt Pick up resistance with low VOC less than 50 gm/litre as per the LEEDS specifications and UV resistance as per IS 15489:2004, Alkali & fungal resistance of required shade (Company Depot Tinted) @ 1.43 Ltr (undiluted)/10 Sqm per two coat diluted with water as per manufacturer instructions over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over over 1mm thick external wall care putty complete all as specified and directed. (Note: Work shall be carried through an authorised applicator of the manufacturer's) |
| 49 | M & L for 100 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed. |
| 50 | M & L for Chequered cement concrete tiles of size 20cm x 20cm x 25mm thick, as in floors etc, including 20 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed with grey cement and pigments to match with the shade of tiles complete all as specified and directed. |
| 51 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed. |
| 52 | Taking down unserviceable distribution boards etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed. |
| 53 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes flush to wall including cover plate for fixing surface type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and directed..(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) Wiring shall be carried out in proper colour i.e Red, Yellow, Blue phases, Black for neutral and green for earth(iii) Unit quoted rate is deemed to include metal flush boxes with cover plate of suitable size(iv) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 54 | All as per item No. 52 above but for One 3/5 pin socket outlet 6 amps point on same board with other switches complete ditto |
| 55 | All as per item No. 52 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 56 | All as per item No. 52 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto |
| 57 | S & F Distribution Board, TPN, 6 Way, 415V, Double door with IP 43 protection, IK 09 with 200 Amps rated bus bar complete all as specified and as diretced |
| 58 | S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43 protection, IK 09, with 200 Amps rated bus bar complete all as specified and as directed. |
| 59 | S & F Distribution Board, SPN 4 Way, 240V, metal Double door with IP 43 protection, IK 09 with 200 Amps rated bus bar complete all as specified and as diretced complete all as specified and directed. |
| 60 | S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection, IK 09 with 200 Amps rated bus bar complete all as specified and as directed. |
| 61 | S & F MCB, TPN, 63 Amps, 415 Volts, 10KA, B Curve including electrically connecting up with wiring lugs complete all as specified and as directed |
| 62 | S & F MCB, SP, 6 to 32 Amps, 240 Volts, 10KA capacity, B Series including electrically connecting up with wiring lugs complete all as specified and as directed |
| 63 | S & F MCB SPN 40 Amps, 240 Volts, 10KA, B curve including electrically connecting up with wiring lugs complete all as specified and as directed |
| 64 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 65 | S & F Switch socket combination, 6A/16A, 5 in 1, flush type complete all as specified and as directed. |
| 66 | S&F socket outlet 5/6 Amps 3 pin flush type 5 pin for the same board complete all as specified and directed. |
| 67 | S&F switch socket combination 5/6 Amps 2 in 1 flush type 5 pin multi purpose for independent board complete all as specified and directed. |
| 68 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 69 | S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 70 | S & F LED, B lamp, 10 Watt complete all as specified and directed. |
| 71 | S & F LED lights fitting 1x 20W, 220V AC (4ft), 6000K, extruded aluminium, decorative ultra slim, linear with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories complete all as specified and directed. |
| 72 | S & F Street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp of size 25x3mm, two Nos with nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer including taking down existing unserviceable brackets complete all as specified and directed. |
| 73 | S & F Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and connecting up complete all as specified and as directed. |
| 74 | M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper conductor cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper conductor cable as earth continuity conductor including taking down of existing unserviceable wiring complete all as specified and as directed.(Note :- (i) Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length(ii) Wiring shall be carried out in proper colour i.e Red, Yellow, Blue phases, Black for neutral and green for earth(iii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 75 | M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper conductor cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper conductor cable as earth continuity conductor including taking down of existing unserviceable wiring complete all as specified and as directed.(Note :- (i) Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length(ii) Wiring shall be carried out in proper colour i.e Red, Yellow, Blue phases, Black for neutral and green for earth(iii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 76 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 77 | Taking down ceiling fan of any sweep, sealing cable end, dismantling blades and removing fan and blades to MES store yard complete all as directed. |
| 78 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00, BEE Five star rated with brushless direct current motor (BLDC) and connecting up with PVC insulated, multistranded copper conductor cables of suitable size from ceiling rose to fan complete all as specified and directed. |
| 79 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 4 core including taking out old one complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately) |
| 80 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil including taking out and removal of bricks protections complete all as specified and directed. |
| 81 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 82 | Removing excavated soil not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 83 | M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) |
| 84 | Supply and laying well burnt sub class 'B' bricks, old size laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed. |
| 85 | M & L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 86 | M & L for cutting roads/ hard standing/ path etc for laying LT cables through pipes of any size n.exc 35cm depth from ground level and making good the damaged surfaces complete as per the existing specifications of roads/ hardstanding/ path etc to match with the existing surfaces complete all as specified and directed. Total in Figures 0.0 0.0 Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |