| 1 | Demolition of Brick work or stone/ boulder masonary built in Cement mortar complete all as specified and directed. |
| 2 | M&L old size brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1.6 complete all as specified and directed. |
| 3 | Dismantling of Wall Panelling/ false ceiling board ,fiber insulation board of any thickness including wooden cover fillets/ aluminium frame work complete all as specified and directed. |
| 4 | S&F Anodised aluminium snap grid frame work for false ceiling, Size of grid 605 x 605mm complete all as specified and directed. |
| 5 | S&F 6mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 6 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 7 | Dismantling of floor, hearth or walls tiles including cement mortar bedding but not backing and rubbish off permises complete all as specified and directed. |
| 8 | M&L 25 mm thick PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in floor etc complete all as specified and directed. |
| 9 | M&L Machine cut kota stone slab flooring 20-25 thick over and including 20mm thick screed bed in CM 1:6, set & jointed in neat cement slurry and pointed in white cement mixed with pigments to match with the floor and polishing complete all as specified and directed. |
| 10 | M&L Machine cut kota stone slab flooring 20-25 thick as in riser of step,skirting ,dado and pillar laid over and including 15mm thick rendering in CM 1:4, set & jointed in neat cement slurry and pointed in white cement to match with the floor and polishing complete and all as specified & directed. |
| 11 | Taking down cement plaster on wall of any description incl racking out joints, hacking for key and scrubbing down with water complete all as specified and directed. |
| 12 | M&L for 15 mm thick rendering in on fair faces of brick / concrete surfaces in cm (1:6) finished even and smooth without using extra cement complete all as specified and directed. |
| 13 | M & L for preparation of newly plastered surfaces of wall & concrete and applying 2mm thick wall care putty including preparation complete all as specified and directed. |
| 14 | M&L for applying two coats of oil bound distemper over a coat of chalk whitening on newly plastered wall surfaces complete all as specified and directed. |
| 15 | M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete. |
| 16 | M&L for applying two coats of oil bound distemper on old plastered wall surfaces complete all as specified and directed. |
| 17 | M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement or as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete.Note : Liquid WPC will be measured and paid separately. |
| 18 | M&L preparation of new plastered or unplastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 19 | M&L Preparing old painted surfaces of walls, chajjas etc by washing rubbing down and stopping and applying two coat of cement base paint white or tinted complete all as specified as directed. |
| 20 | M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified and directed. |
| 21 | M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 22 | Taking down chowkats or frame with shutters (without taking off shutters from the frames) n. Exc 1.5 Sqm each |
| 23 | Same as item No 22 above but exc1.5 Sqm and n.exc. 4 Sqm. |
| 24 | S&F steel windows with side hung shutters incl projecting type hinges with one MS flat iron 25x3 mm of appx 200mm length and two nos MS Tower bolt 150mm long and one peg stay on each leaf with glazing bars, dovetailed or welded complete all as specified and directed. |
| 25 | Same as item No 24 above but without glazing bar. |
| 26 | S&F steel ventilators with top hung shutters including hinges, steel peg stay complete. |
| 27 | S & F 30 mm thick flush shutters solid core construction with particle board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats. |
| 28 | S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (with sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkats for windows, ventilators,etc complete all as specified and directed. |
| 29 | S&F 100 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed. |
| 30 | S&F aluminum alloy anodised sliding door bolts with hasp & staple & fixing clips of sheet cast extruded section & fixing bolts & sliding bolts of extruded section 300 mm long. |
| 31 | S&F mild steel, 150 mm long ordinary helical door spring incl roller and roller plate complete all as specified and directed. |
| 32 | S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 33 | S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 34 | S&F floor door stopper 140 mm overall length of cover plate of aluminium alloy body and tongue, anodised. With hard drawn spring, fixed in floor complete all as specified and directed. |
| 35 | S&F in repair GI wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staple complete all as specified and directed. |
| 36 | S & F pressed steel frame of size 125 X 60 mm and 1.25 mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed. |
| 37 | S&F framed work such as grills gratings etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed, baluster walk ways, railings, framework of water tanks and similar work conforming to Fe410-0 or Fe310-0 . |
| 38 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for insertion of hold fast ,coping lintels ,plinth course, cills etc incl necessary form work complete all as specified and directed. |
| 39 | S&F in repair 5 mm thick looking mirror selected quality glass exc 0.50 sqm each and fixed to wall with stainless steel flat head mirror screw cups and washers including polished , rounded off edges of glass and drilling hole in glass complete as specified and directed. |
| 40 | M & L for 75 mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3. |
| 41 | M&L 5mm thick rendering on fair faces of bk/ concrete surfaces as on ceiling in CM (1:3), finished even and smooth (without using extra cement) complete all as specified and directed. |
| 42 | M&L for preparation of newly plastered surfaces of ceiling and applying 2mm thick wall care putty including preparation of new surface complete all as specified and directed. |
| 43 | M&L for applying two coats of oil bound distemper on ceiling over a coat of primer on prepared surfaces including rubbing with sand paper complete all as specified and directed. |
| 44 | M&L for sand filling under floors or in foundations, laid in layers n exc 15cm thick, spread levelled including watering and consolidation complere all as specified and directed. |
| 45 | M&L for 100 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) complete all as specified and directed. |
| 46 | M&L for 55 mm thick PCC 1:2:4 Type B1 (using 20mm graded stone aggregate) complete all as specified and directed. |
| 47 | Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 48 | M&L old size brick work with sub class 'B' bricks laid flat in floors laid in dry complete all as specified and directed. |
| 49 | M&L for 100 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) complete all as specified and directed. |
| 50 | M&L Rubber moulded coloured chequered tile 20 cm x 20 cm x 20-22 mm/ 30 cmx30cmx25 mm thick, set, jointed and pointed in neat cement slurry in floors ( with grey cement and pigments) over and including 20 mm thick Screed bed or bedding of cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 51 | Dismantling of Plain or corrugated steel sheeting of any, gauge , thickness, including nainital or similar pattern roof coverings in any types. |
| 52 | M&L Pre painted galvalume sheet aluminium zinc coating GI based corrugated steel sheet with curved type 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /ridge/cladding to wall fixed with self tapping screws as specified.(cut groves & put in sheet and covered with PCC and plaster at near bldg connecting sheds). |
| 53 | Dismantling of fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section |
| 54 | M&L for Roof Trusses (framed trussed purlins ,crane gantries , rails and fastenings and heavy brackets framing (beam tee, angle ,channel or flat sections) including distance piece ,cleats etc.e all as specified & directed. |
| 55 | M&L Mild Steel Work for wind ties for roof including securing bolts complete all as specified and directed. |
| 56 | Taking down carefully copper/aluminium point wiring (Light,fan,socket are power) complete fitting such as switches, ceiling rose, regulator, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors, etc. all as specified and directed. |
| 57 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one light/fan/call bell / exhaust fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 2.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed. |
| 58 | Same as item No 57 above but one 3/5 pin socket out let 5 amp on same board with other switches. |
| 59 | Same as item No 57 above above but socket 5 amp on independent board. |
| 60 | Same as item No 57 above above but socket out let 3/6 pin 15 Amp with 2.5 sq mm size copper conductor for power point on indipendent board. |
| 61 | S & F for switch piano, flush type, 5 amps, single pole , one way , 230 volt complete all as specified and directed. |
| 62 | S & F for 2/3 pin, 5 Amp/ 6 Amp , socket outlet, flush type, 2 in 1 complete all as specified and directed. |
| 63 | S&F switch socket combination 2 in 1, 6 pin 16 Amps multipurpose type 240 volts complete all as specified and directed. |
| 64 | Supply & Fixing ceiling rose surface backlite 65X20 mm two to three terminals complete all as specified and directed. |
| 65 | Supply & Fixing lamp holder PVC / Ploycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 66 | M & L for power/sub main wiring with two runs of single core 6 Sqmm size and one run of single core 6 Sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC conduit complete all as specified and directed.( Note - two runs of 6 Sqmm single core copper conductor and one runs of 6 Sq mm copper conductor shall be measured as one unit length.) |
| 67 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 12 way. |
| 68 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail TPN 4 way. |
| 69 | S & F in replacement of MCB TPN 40 to 100 Amps 415 volts, 10KA \\"C\\" curve. |
| 70 | S & F in replacement of MCB SPN 32 Amps 240 volts, 10 KA, \\"C\\" curve. |
| 71 | S & F in replacement of MCB SP 5 to 32 Amps 240 volts, 10 KA, \\"C\\" curve. |
| 72 | Supply & Fixing in replacement LED lamps 9 W. |
| 73 | Taking down existing light fitting of any type, make & capacity . |
| 74 | Supply and fixing LED lights fitting 1x 20W, 220V,AC integrated type including driver, Extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser , 4 ft,2000lm,voltage protection range 140V -270 V,NW 4000K , ,connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 75 | Same as above item No 74 but of 10 W 2 feet . |
| 76 | Supply and fixing integral LED bulkhead luminaire, 10 W, 230 Volts, IP 65 protection decorative surface mounted , complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. |
| 77 | Supply & fix exhaust fans heavy duty complete steel body and copper winding fan motor,1400 rpm ,AC single phase 230/ 240 V, 50 Hz AC, of size 300 mm sweep with louver including breaking necessary hole in wall for fixing the exhaust fan and making good to disturbed surfaces with cement mortar to match with existing after commissioning complete all as specified and directed. |
| 78 | Supply & Fixing wall mounting fan complete steel body and copper winding fan motor 400 mm sweep, 230 V AC,including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. |
| 79 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL with top edge of plate not less than 1.50 m below normal ground level) connected to galavanised earth lead wire 4.0 mm dia (7.5m) as means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, GI pipe (ISImark) light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregate ) chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover 1:2:4 , type B-1(using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade(ISI marked) for watering all as shown in electrical plate No 3 of SSR Part-I and connected to earth test point including testing of earthing & dismantling /taking down existing old / unserveciable earthing complete all as specified and directed. (Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 meter beyond the earth plates electrode.) Please Enable Macros to View BoQ information |