| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tilling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises complet all as specified and directed |
| 2 | M&L for vitrified Ceramic tiles light shed 8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with CM (1:6) complet all as specified and directed |
| 3 | All as per ser item No 02 above but as in vertical surfaces in skirting and dado including rendering/screeding including 10 mm thick screed bed with cement mortar (1:6) complete all as specified and directed. |
| 4 | M & L for coloured glazed ceramic tiles in vertical surface 7mm thick exc 0.06 Sqm but not exc. 0.20 Sqm, set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick rendering in cement mortar (1:6) as backing for tiles complete all as specified and directed. |
| 5 | M & L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 Sqm but not exc. 0.16 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM (1:6) complet all as specified and directed |
| 6 | M&L for 15-20mm thick granite slab, machine cut, well polished, bedded in 15mm thick in CM (1:6) as in cooking plaforms ,window cill & like and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixtures of pigments to match the shade of granite stone including cutting, polishing and rounding of edges etc. complete all as specified and directed. |
| 7 | M & L Machine cut Kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick Cement Mortar (1:6) complete. |
| 8 | M & L Kota stone slab 15-18 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and incl 10mm thick rendering in cement mortar (1:4) , on fair faces of brick work or concrete surfaces as backing complet all as specified and directed |
| 9 | M & L for Cement concrete type B-0, (1:2:4) (12.5 mm graded aggregate), 25 mm thick in flooring etc complete all specified and as directed |
| 10 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc, dressed stone work and precast concrete article complet all as specified and directed |
| 11 | M & L for Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complet all as specified and directed |
| 12 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water,complet all as specified and directed |
| 13 | M & L for 10 mm thick rendering in CM (1:6) on brick work or concrete surfaces of wall and finished surfaces fair and even without using extra cement ccomplet all as specified and directed |
| 14 | M & L for applying a thin layer of 1.0mm thick white wall care putty over newly plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 15 | M & L for 15 mm thick rendering in CM (1:4) over fair faces of brick work or concrete surfaces of wall and finished surfaces fair and even without using extra cement with WPC complet all as specified and directed |
| 16 | Supply Only integral water proofing compound |
| 17 | M&L rendering 5 mm thick on fair faces of brick work or concrete surfaces in CM (1:3) on ceiling/chajja etc upto triple storey and finishing the surface even and smooth without using extra cement. |
| 18 | M&L for preparation and filling of pitting/cracks (including V groove cutting of cracks/deepening) on surfaces with crack seal and finishing the surfaces as per existing treatment complete all as specified and directed. |
| 19 | M&L for repairing of R.C.C projections, chajjias, roofs, facia etc in patches not exceeding 3 Sqm in each patch by necessary preparation, Scarpping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose R.,C.C surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and finished with cement and sand motar (1:3) using coarse sand and work in patches including necessary form work and applying two coats of finishes to match with the existing surfaces in at any height complete all as specified and directed. |
| 20 | S & F thin flexible galvanised steel wire with hexagonal gaps chicken wire mesh about half to one inch dia incl fixing with screws, nails etc complet all as specified and directed |
| 21 | M & L for preparation of new plastered/decorated wall surfaces and applying two coats of distempering with oil bound distemper as per manufacturer instruction white or tinted complete all as specified and directed. |
| 22 | M & L for preparation of new plastered/decoarated wall surfaces and Finishing walls with Acrylic Smooth exterior weather coat putty & paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 23 | M&L for two coats of oil bound distemper on newly plastered surfaces of celling including prepration of surfaces complete all as specified and directed. |
| 24 | M & L for applying a thin layer of 1.0mm thick Birla white putty/JK white wall care putty on wall surfaces including removal of existing treatment and making the surface uniform and smooth including two coat of oil bound distemper complete all as specified and directed. |
| 25 | M & L for Preparation of old decorated surfaces of ceiling and applying one coat of distempering with oil bound distemper as per manufacturer instructions white or tinted complete all as specified and directed. |
| 26 | M&L 1mm thick exterior weather coat putty and two coat of exterior weather coat paint with roller white or tinted on walls or fascia of roof or chajjas on old decorated prepared plastered/painted surfaces of bldg including 100 % removing of existing paint complet all as specified and directed |
| 27 | Taking down chowkhat or frame exc 1.5 sqm but not exc 4.00 sqm (without taking off shutter) and removing to store/taking in safe custody for refixing the same complete all as specified and directed. |
| 28 | Taking down chowkhat or frame n.exc 1.5 sqm (without taking off shutter) and removing to store/ taking in safe custody for refixing the same complete all as specified and directed. |
| 29 | S & F solid PVC frame of size 50 mm x 47 mm made out of 5 mm single side prelam PVC sheet & edges will be printed to match with prelam sheet rein forced with MS square tube complete all as specified and directed. |
| 30 | S&F factory made solid panel PVC door shutter 30mm (Style) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame complete all as specified and directed. |
| 31 | S & F 100mm stainless steel Butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed. |
| 32 | S & F 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 33 | S & F aluminium handles, cast type, D shape anodised of size 150mm complete all as specified and directed. |
| 34 | S&F aluminum frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified and directed. |
| 35 | S&F any colour, aluminum door shutters , aluminium section weighing 0.55 Kg/ Sqm including necessary jointing cleats, glazing clips, ruber neoprene packing, handles & tower bolts 02 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 36 | S&F anodised aluminium window(Sliding or side hung shutter) and ventilator shutters, with powder coating (minimum thickness of powder coating 50 micron) side hung/ sliding type without sash bars, aluminium sections weighing not less than 1.0 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21,100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed |
| 37 | Supply & fix only sheet glass ordinary quality 3mm thick exc 0.5 sqm in each pane complet all as specified and directed |
| 38 | S&F Sheet glass 5.5 mm thickness, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complet all as specified and directed |
| 39 | S&F 4mm thick figured glass pin head type and glazing with oil putty or wooden beads or rubber beading in squares n exc 0.50 Sqm each pane complete all as specified and directed. |
| 40 | S& F galvanised mild steel wire clothes 0.56 mm nominal dia of wire and average width of aperture1.18 mm complete fixed with tinned tacks or galvanised wire staples all as specified and as directed |
| 41 | S & F in repair double action floor spring hydraulically regulated made up of minium 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty complete all as specified and directed . |
| 42 | S & F 100 mm long mortice lock with four levers (vertical type), brass body complete all as specified and directed. |
| 43 | S&F as in repair PVC connections 15mm size with PTMT nuts of length 600 mm all as specified and as directed. |
| 44 | S&F in repairs 10 ltr capacity PVC low level flushing cistern white, ISI marked make as specified with inlet, float valve and handle including breacket with 32mm dia PVC pipe 600mm long complete all as specified and directed |
| 45 | S & F in repairs counter top wash basin, white, flat back, size 550 x 400 mm including a pair of bracket, 32mm dia CP waste coupling with waste pipe screwed to iron pipe complete all as specified and directed. |
| 46 | S&F in repairs15mm bore cast copper alloy chromium plated fancy type WHB mixer tap for cold & hot complete all as specified and directed |
| 47 | S&F in repair Vitreous china Urinal, Half stall type, white including32mm cp waste coupling with waste pipe compelete all as specified and directed. |
| 48 | S & F in repair Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete all as specified and directed. |
| 49 | S & F as in repair of white soft closing seat cover for pedestal pattern water closet including fixing bolts complete all as specified and directed. |
| 50 | S & F as in repair Health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and as directed. |
| 51 | S & F in repair 6mm thick looking mirror of 1st quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete. |
| 52 | S&F in repair 15 mm dia bore bib taps, brass chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 53 | S&F in repair brass chromium plated tubler towel rail 20mm dia D type, 60cm long between flanges complete all as specified and directed. |
| 54 | S & F in repair brass chromium plated soap dish fixed to wall with CP screw complete all as specified and directed. |
| 55 | S&F of Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed. |
| 56 | S & F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 45cm long complete all as specified and directed. |
| 57 | S & F in repair 20mm bore cut to length as required stainless steel decorative draphery rods with brackets and decorative finails as required colour complete all as specified and directed. |
| 58 | S&F in repair 15 mm dia stop/angle valves, cast copper alloy, CP fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 59 | S&F in repair PVC floor trap size 75/100mm dia out let with grating including connection to waste pipe with cement jointing including taking down existing trap complete all as specified and directed |
| 60 | S & F in repairs CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11 includig all fittings on walls/ceiling or laying in floors including necessary cutting/chasing of walls and floors complete. |
| 61 | S & F of Male Brass Threaded Adaptor (MTA/ MBTA) or female Brass Threaded Adaptor (FTA/ FBTA) 20mm dia complete. |
| 62 | S & F in repairs CPVC pipes 25 mm outer dia SDR 11 & Plain CPVC SDR 11 includig all fittings on walls/ceiling or laying in floors including necessary cutting/chasing of walls and floors complete. |
| 63 | S & F of Male Brass Threaded Adaptor (MTA/ MBTA) or female Brass Threaded Adaptor (FTA/ FBTA) 25mm dia complete all as specified and directed. |
| 64 | S & F in repair 25mm dia bore CPVC gate valves with handle or wheel head, screwed both ends for pipe and fixed to CPVC /GI pipe incl all fittings and accessories as required complete all as specified and directed. |
| 65 | S & F in repair 20mm dia bore CPVC gate valves with handle or wheel head, screwed both ends for pipe and fixed to CPVC /GI pipe incl all fittings and accessories as required complete all as specified and directed. |
| 66 | S& F 1000 Ltr capacity of rotational moulded polyethylen water storage tank (Cylindrical vertical with closed tap) hoisted and fixed in position including S&F 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600 mm long with fitting and including dismantling of tank complete all as specified and directed. |
| 67 | M&L for PCC (1:2:4) type B-1 as roof padding concrete to bring the extg slab in slope of 1:40 complete all as specified and directed. |
| 68 | M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20kg per sqm incl cleaning surfaces complete all as specified and directed. |
| 69 | M&L for fixing APP based polymeric membrane minimum weighing 3.6kg/sqm and min 3mm thick reinfirced with polyster noin wove faric (wt not less than 150gms/sqm) land on primed surface by forced application complete all as specified and directed. |
| 70 | M & L for applying two coat of Aluminium paint over surfaces of any description including preparation of surfaces etc complete all as specified and directed. |
| 71 | M & L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3) complete all as specified and directed. |
| 72 | Dismantling of wall and ceiling boards, any thickness including cover fillets complete. |
| 73 | M & L for anodised aluminium snap grid frame work of size 600mm X 600mm for false ceiling incl hanging to 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 74 | S&F 4mm thick HSPC non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling complete all as specified and directed. |
| 75 | S & F sandwiched hollow PVC wall Lining/panelling consisting of 5mm thick Plain designer colour PVC sheet but single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on wall/PVC frame including removing of existing wall panelling etc complete all as per specified and directed. |
| 76 | Dismantaling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as per specified and directed. |
| 77 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as per specified and directed. |
| 78 | S & F rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 79 | S & F Pre-painted galvatume aluminum zinc coating (AZ 150) GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 80 | Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed |
| 81 | M & L for preparation of new or previously untreated steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed |
| 82 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing from the site. complete all as specified and directed. |
| 83 | M & L for cement concrete type D-2, (1:4:8) using 40mm graded stone aggregae as in foundations, filling and mass concrete complete all as specified and directed. |
| 84 | Sand filling under floors for cushioning of including watering and consolidation complete all as specified and directed. |
| 85 | M & L for machine pressed precast conctete interlocking paver block matt glossy finish any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigmentcomplete all as specified and directed. |
| 86 | M &L Chequered cement concrete coloured tiles 250x250x25 mm thick laid over and including 20 mm thick bedding layer in cement mortar 1:6 set, jointed and pointed in cement mortar (1:3) with grey cement and using pigment as in paths complete all as specified and directed. |
| 87 | Excavation in trenches not exceeding 1.5m in width and not exceeding 1.5m deep, in soft/loose soil for foundation, laying of pipes, wells, cesspits, manhole, pier holes & getting out complete all as specified and directed. |
| 88 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 89 | Removing excavated material to distance not exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 90 | M&L for providing concrete bed in PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in bed to drain pipes, dia of 150mm, including packing under and haunching against the sides of the pipes completely after pipes are laid and tested complete all as specified and directed.Note: Width of concrete bed shall be outer diameter of drain pipe plus 30cm. |
| 91 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 92 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc incl fixing with iron clamps complete all as specified and directed. |
| 93 | S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed. |
| 94 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc incl fixing with iron clamps complete all as specified and directed. |
| 95 | S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed. |
| 96 | M&L for providing concrete bed in PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in bed to drain pipes, dia of 110mm, including packing under and haunching against the sides of the pipes completely after pipes are laid and tested complete all as specified and directed.Note: Width of concrete bed shall be outer diameter of drain pipe plus 30cm. |
| 97 | M & L for cement concrete type D-2, (1:4:8) using 40mm graded stone aggregae as in foundations, filling and mass concrete complete. |
| 98 | M&L for cutting into existing manholes for connecting new drains, dia of pipe 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1, smooth finished, and reforming benching as required complete all as specified and directed. |
| 99 | Demolition of reinforced cement concrete in ground floors and pavings n exc 15 cm thickness below or above GL complete all as specified and directed. |
| 100 | M&L for precast reinforced cement concrete (1:2:4), type B-1, using 20mm graded stone aggregate as in manholes covers and similar articles, set in cement mortar 1:4 including necessary form work and similar articles complete all as specified and directed. |
| 101 | M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 102 | Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed. |
| 103 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 104 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 105 | Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed. |
| 106 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 107 | (a) One light point controlled by one, one way switch 5 Amps |
| 108 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 109 | (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 110 | (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 111 | (e) One bell point controllled by one bell switch |
| 112 | Description all as per item No 115 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH insulated unsheathed 1100 volts grade for 5/15 amps point including necessary running of 2.5 sq mm copper FRLSH wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all specified and directed. |
| 113 | Description all as per item No 115 here in before but using 4 sq mm single core copper conductor cable of multistranded FRLSH insulated unsheathed 1100 volts grade for 5/15 amps point controlled with modular motor starter for air conditioner including necessary running of 4 sq mm copper FRLSH wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 114 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and directed. |
| 115 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed. |
| 116 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed. |
| 117 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed. |
| 118 | S & F modular motor starter 32 A capacity 2 module complete all as specified and directed. |
| 119 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 120 | S& F Modular Bell push 6A 1 module complete all as specified and directed |
| 121 | S & F Fan step regulator, 120W - 2 module complete all as specified. |
| 122 | S&F Buzzer, Ding Dong AC. 230 volts, complete all as specified. |
| 123 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 124 | S & F for sheet metal enclosure MCB DB TPN 4 way suitable for MCCB with 200 Amps rated bus bar 415 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 125 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 126 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 127 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 128 | S & F for MCCB four pole rated capacity 100 Amps, 415 Volts breaking capacity 16 KA complete all as specified and as directed. |
| 129 | Re-fixing of exhaust fan of 300 mm sweep made of plastic/steel body complete with louver including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. |
| 130 | Hanging only ceiling fan including provision of fastner, cable from ceiling rose or connector to fan |
| 131 | S & F LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 132 | S & F LED lights fitting 1x 10 W, 2 feet 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 133 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 134 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 135 | Taking down carefully Split type AC of any capacity with all accessories such as indoor unit, out door unit, copper pipe inlet outlet, flair nut etc. and shifting to new position including minor accessories, and making good the opening of old location with cement mortor 1:3, treating the wall to matching with existing surface finish and making opening holes on brick wall at new location and gap well finish with cement mortor 1:3, making good the wall surface to match with existing surface, installation and commissioning with replacement of insulation of suction & discharge line complete all as directed.complete all as specified and directed. |
| 136 | M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and connected to earthing point complete all as specified and as directed. |
| 137 | Taking up/down XLPE aluminium conductor cable of any size all as specified and diected |
| 138 | M&L for laying, comnecting and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 35 sq. mm. of 4 core all as specified and directed |
| 139 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified and directed. |
| 140 | Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed |
| 141 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 142 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 143 | Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. note :-all measurement in meter |
| 144 | Supply,laying and in replacement galvanised steel tubing light grade complete with all fitting of size 50 mm dia for cable protection along with pole across road etc. Complete all as specified and directed. Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail