Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-04-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-04-2026 |
| 2 | 02-04-2026 | Tender Corrigendum | Other | 14-04-2026 |
| 3 | 02-04-2026 | BOQ Corrigendum | BOQ | 14-04-2026 |
| 4 | 02-04-2026 | Tender Corrigendum | Other | 21-04-2026 |
| 5 | 02-04-2026 | BOQ Corrigendum | BOQ | 21-04-2026 |
| Sl. No. | Item Description |
| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified and directed. |
| 2 | Dismantling of asbestos, cement (corrugated, semicorrugated, etc.) sheets in roof coverings , complete all as specified and directed. |
| 3 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 4 | Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter, ridge & similar works fixed with self tapping screws complete all as specified and directed. |
| 5 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 6 | Structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified and directed. |
| 7 | Ditto as per item No 6 here in before but erection and fixing only complete all as specified and directed. |
| 8 | Dismantling wall and ceiling boards, fibre pulp insulation etc or insulation boards/ slabs / blankets, any thickness, including cover fillets, complete all as specified and directed. |
| 9 | False ceiling of grid of galvanzed steel tee/ angle (power coated ) of grid size 600x600mm as comprising of main and secondry tee ( weight not less than 240gm /RM) and wall perimeter angle (weight of section not less than 217gm/RM) all around of walls suspended with 4mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels insert of any type including 4mm thick designer ceiling boards size 595x595mm fixed in position complete all as specified and directed. |
| 10 | Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed. |
| 11 | Walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and as directed. |
| 12 | Description all as per item No 11 above but except stone. |
| 13 | Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified and directed. |
| 14 | Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 15 | Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for including removing the rubbish off the premises all as specified and as directed. |
| 16 | Demolition of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed |
| 17 | 20mm thick granite (of approved type colour) work (table rubbed & polished) in jambs, pillars, window cills, cooking platform laid over and including 15mm thick cement screed (1:4) and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the colour of granite stone including cutting and moulding the edges, complete all as specified and directed.Note : A hole shall be drilled in cooking platform for gas pipe.The rates quoted for the item shall include the same. |
| 18 | RCC (1:2:4) type B1 (using 20mm graded aggregate) for beams, centilevers, bresssummers, lintels, chajjas & Kitchen slab over 1.5m span etc complete all as specified and directed. |
| 19 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and as directed. |
| 20 | Mild steel bars 05mm dia TMT Bars & over upto & including 10mm dia and over cut to length bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with and includig mild steel wire not less than 0.9mm dia or securing with clips complete fixed in repairs all as specified and directed. |
| 21 | Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including supports, overhangs, etc. complete all as specified and directed. |
| 22 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 23 | Non-skid coloured ceramic tiles 7 to 8 mm thick (square/ractangular) area of each tiles exceeding 0.06 Sqm but n.exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement cement to match the surface laid over & including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed. |
| 24 | Non-skid coloured ceramic tiles 7 to 8 mm thick (square/ractangular) area of each tiles exceeding 0.11 Sqm but n.exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement cement to match the surface laid over & including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed. |
| 25 | Ditto all as per item No 24 here in before but as in dado/skirting etc including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 26 | Glazed ceramic tile 450x350x7/8mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick bedding layer in cement and sand mortar 1:3 complete all as specified and as directed. |
| 27 | 18-20 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge. (Size of Kota Stone slab shall be 52 cm x 52 cm). |
| 28 | Ditto all as per item No 27 here in before but as in skirting/dado incl 10mm thick CM 1:4 complete all as specified and directed |
| 29 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm and not exceeding 4 Sqm each, complete all as specified and directed. |
| 30 | Taking down chowkats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5 Sqm each, complete all as specified. |
| 31 | Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick flat iron projecting 10cm on either side & tarring back of chowkats and holdfasts with & including PCC 1:3:6 type C-0 (using 12.5mm graded crushed stone aggregate) as in back filling of pressed steel frame, complete all as specified & directed. |
| 32 | Factory made Pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick flat iron projecting 10 cm on either side & tarring back of chowkats and holdfasts with & including PCC 1:3:6 type C-0 (using 12.5mm graded crushed stone aggregate) as in back filling of pressed steel frame, complete all as specified & directed. |
| 33 | 40mm thick flush shutters, solid core with particle board exterior grade as per IS 2202 of 199 (Part-I) flush door shall be internally lipped as per clause .8.52.2 of SSR Part-I 2009, complete all as specified & as directed. |
| 34 | 35 mm thick, 2nd class hard wood , glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified. |
| 35 | Powder coated Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 36 | Powder coated aluminium Anodised door (shutters), aluminium section weighing not less than 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 37 | Powder coating Anodised aluminium window and ventilator shutters, side hung type without sash bars aluminium sections weighing 0.55 kg/m (glass & wire mess shall be measured and paid separetely) including necessary joining cleats, glazing rubber packing, anodised aluminium clips, snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 Nos.) suitable handle (1 N.) and 100 mm long aluminium tower bolt (02Nos) per shutters complete all as specified and directed. |
| 38 | 5.5 mm thick tinted sheet glass, selected quality and glazing with aluminium beads and rubber packing in square not exceeding 0.5 square metre in each pane, complete all as specified and as directed. |
| 39 | Galvanized mild steel wire-cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 40 | Door closer of aluminium (Die cast body), hydraulically regulated, designation No 3, universal type, suitable for door shutters of size 851mm to 1000mm of width , ISI marked fixed in repairs, complete all as specified and as directed. |
| 41 | PCC 1:2:4, B-1 (20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles, as in protection for interlocking tiles as directed including necessary form work, complete all as specified and directed. |
| 42 | Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as shown in drawing of relevant item in MES, schedule Part-II , 2020 as specified and as directed. |
| 43 | Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed. |
| 44 | Preparation new steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 45 | Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer,complete, all as specified and directed. |
| 46 | Preparation of old steel surfaces of any description exc 10 cm width or girth, and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 47 | Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed. |
| 48 | 250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and as directed. |
| 49 | 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed. |
| 50 | Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and as directed. |
| 51 | 300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate fixed, complete all as specified and directed. |
| 52 | S&F in Repair 25 mm dia stainless curtain steel rod complete with stainless bracket and side caps fixed in position by drilling holes in wall and fixed the bracket with rawl plug and SS screw all as specified and as directed. |
| 53 | 50mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in plinth protection finished even and fair and making 50mm deep joints at every 3 metre interval and at every corner and filling the joints with bitumen of grade 85/25 and sand mixture 1:3 complete all as specified and directed. |
| 54 | 04 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed. |
| 55 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 56 | Rendering 15mm thick in cement mortar 1:6 on stone wall or other than fair faces of bricks work or stone surfaces and finished the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 57 | Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 58 | GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste in repairs in patches n exc 5 sq. m each, including taking down old and jointing new to old as required all as specified and directed. |
| 59 | Applying 3mm thick wall care putty over newly plastered surfaces of wall, complete all as specified and directed. |
| 60 | Preparation of newly putty surface/plastered surface of walls and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed. |
| 61 | Preparation of newly plastered surface of walls applying two coats of cement base paint over a coat of alkali resistance primer all as specified and directed. |
| 62 | Preparation of old painted surfaces by washing, rubbing down and stopping of distempered and painted walls and applying one coats of oil bound distemper complete all as specified and as directed. |
| 63 | Preparation of old painted surfaces by washing, rubbing down and stopping of plastered surfaces and applying one coats of cement base paint white or tined on wall complete all as specified and as directed. |
| 64 | Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc., complete all as specified and as directed. |
| 65 | Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed. |
| 66 | Mild steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 67 | Mild steel water tubing of 20 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 68 | Refixing old steel water tubing of 15mm bore and connections in new or old position fixed to walls, ceilings and floors etc. including fittings as requiered, complete all as specified and directed. |
| 69 | Refixing old steel water tubing of 20mm bore and connections in new or old position fixed to walls, ceilings and floors etc. including fittings as requiered, complete all as specified.and directed. |
| 70 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting exc 20 cm girth Stone concrete block or slab walls all as directed. |
| 71 | Vitreous china wash basin, white, flat back, size 550x400mm with full pedestal with & including CP basin mixer including waste pipe porcelain stopper a pair of CI brackets fixed in repair complete all as specified and as directed. |
| 72 | PVC valve less symphonic action type flushing cistern 10ltr capacity , low level white with inlet ball valve float and handle including brackets fixed in repairs, complete all as specified and directed. |
| 73 | Stop valves/angle valve, cast copper alloy, chromium plated fancy type screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15 mm, supplied and fixed in repairs complete all as specified and directed. |
| 74 | Chromium plated brass towel rail 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls and fixed in repairs complete all as specified and as directed. |
| 75 | Bib taps, fancy type chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fixed in repairs complete all as specified and directed. |
| 76 | Supply only PVC connection 15mm size with PTMT nuts on both ends of length 450mm complete all as specified and directed. |
| 77 | Brass Chromium plated shower roses 75 mm size with or without swivel joints, including fixing to steel pipe or union fixed in repairs, complete all as specified and as directed. |
| 78 | Pillar taps 15mm cast copper alloy CP, fancy type with capstan head, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut, screwed for iron pipe 15 mm bore.fixed in repairs, complete all as specified and as directed. |
| 79 | Vitreous china squatting pan \\"Orissa Pattern\\" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'P' trap 110mm bore, connection to trap and flush pipe fixed in repairs complete all as specified and directed. |
| 80 | 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial quality ply-wood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repairs, complete all as specified and as directed. |
| 81 | Brass chromium plated soap dish any type fixed to plugs with chromium plated brass screws fixed in repairs, complete all as specified and directed. |
| 82 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 45cm long fixed in repiars, complete all as specified and directed. |
| 83 | PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 84 | Taking down eaves gutters and rain water pipe , soil and waste pipe PVC or CI (any size or pattern ), including all fittings, heads , shoes bends , swan-necks etc all as specified and directed. |
| 85 | 110mm bore PVC SWR Type-B pipes (pressure not less than 6 kg /cm2) single socket in any length with rubber joints laid in floors/trenches etc all as specified and directed. |
| 86 | 110mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber joints fixed to wall with PVC/MS holder clamp etc complete all as specified and as directed. |
| 87 | 75mm bore PVC SWR Type-B pipes (pressure not less than 6 kg /cm2) single socket in any length with rubber joints laid in floors/trenches etc all as specified and directed. |
| 88 | PVC (SWR) vent cowl for 110mm dia fixed, all as specified and directed. |
| 89 | PVC (SWR) bends any radius 110 mm bore, complete all as specified and directed. |
| 90 | PVC (SWR) bends any radius 110mm dia with access doors complete all as specified and directed. |
| 91 | 110mm PVC (SWR) junction single, (single T) equal or unequal provided with access door, complete all as specified and directed. |
| 92 | PVC (SWR) bends any radius 75 mm bore, complete all as specified and directed. |
| 93 | PVC (SWR) bends any radius 75mm dia with access doors complete all as specified and directed. |
| 94 | 75mm PVC (SWR) junction single, (single T) equal or unequal provided with access door, complete all as specified and directed. |
| 95 | Rotational moulded polyethylene water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) 3 layer hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and as directed. |
| 96 | Steel windows/ventilator (Box type) factory made with double shutter with or without dovetailed bar ( glass & glazed shutter) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3 .Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item |
| 97 | Ditto as per item No 96 here in before but without glazing bars. |
| 98 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15 of approved design/pattern with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @200mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed. |
| 99 | Roughening surfaces of old concrete floor/terrace by picking incl taking down existing detoriated/decayed tar felt or any treatment including lose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean and washing down with water to remove dust etc and removing the scraped materials debris to a distance not exc 1000m all as specified and directed.Step 1:-10mm thick screed bed or bedding layer in CM 1:3 mixed with WPC @3% by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. Supply only liquid water proofing compound conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement)Note : WPC shall be measured and paid seperately.Step 2:- Cleaning of plastered roof surfaces and applying a coat of bitumen primer @0.30 Kg/Sqm on top of dry surface of finished cement mortar plaster complete all as specified and directed.Step 3:- One layer of APP based polymeric membrane minimum weighing 3 Kg/Sqm & minimum 3mm thickness reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) land on primed surface by forced application complete all as specified with lap of 100mm and over lap shall be sealed by flame as directed.One coat of hot blown bitumen of grade 85/25 @1.2kg/sqm be applied over APP membrane surfaces.Step 4:- Applying two coats of aluminium paint on top of membrane. For non approachable roof. Note:- The work of water proofing treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. |
| 100 | Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in any type of soil, complete all as specified and directed. |
| 101 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plain and getting out etc in any type of soil, complete all as specified and directed. |
| 102 | Plain Cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, all as specified directed. |
| 103 | Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 104 | Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 105 | Rolled mild steel sections as in gusset plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk foring holes, without any attachement conforming to Fe 410-W(Gde E- 250)quality A , complete all as specified and directed. |
| 106 | Non skid coloured ceramic tiles 7 - 8 mm thick area of each tile exceeding 0.18sqm but not exceeding 0.38sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shed of tiles laid over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 107 | Ditto all as per item No 106 here in before but as in dado/skirting etc incl 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 108 | Hardcore of broken stone or boulder of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick, watered and rolled/rammed to a true surface, complete all as specified and directed.. |
| 109 | 150mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified and directed. |
| 110 | Chromium plated brass wall/ wash basin mixer for mixing hot & cold water screwed down for iron pipe complete with wall flange (without hand & over head shower) screwed down for 15mm bore GI pipe complete all as specified and directed. |
| 111 | Vitreous china wash down water closet (pedestal pattern) white incl fixing bolt, plaster water closet seat cover black/white closed pattern with flat bottom and cover mild steel chromimum plated hinging device and incl 32mm dia waste pipe complete all as specified and directed. |
| 112 | Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc built up from two or more beam or channel sections or angles with plates including lattice bars, stiffeners, gussest plates etc complete all as specified and directed. |
| 113 | Aluminium body Mortice lock,4-levers vertical type, size 100 mm with & including escutcheon plates and two keys, complete all as specified and as directed. |
| 114 | Urinal spreader of PTMT of size 15mm bore complete all as specified and directed. |
| 115 | Liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 116 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible spirochrome flex tube and ABS wall hook including making connections and fixed in repair in position complete in all respect as specified.Make-Jaquar Cat part no. ALD-573 or its equivalent cat part of make specified in list make, as approved by GE. |
| 117 | 20 mm dia bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairs complete all as specified and directed. |
| 118 | Nipple suitable for HDPE water tank (min weight 20mm 45gms complete all as specified and directed. |
| 119 | Vitreous China urinal with CP spreader Chrome finish hole and fixing accessories Half stall type (back or corner wall type)(size 355mm x 340mm x535mm) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including PVC Connection,waste pipe and coupling. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) fixed in repairs complete all as specified and as directed |
| 120 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 121 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 122 | 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed. |
| 123 | Precast cement concrete (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:6) including necessary form work complete all as specified and directed. |
| 124 | PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 125 | Spreading & levelling in layers n exc 25cm thick & well ramming including watering as required complete all as specified and directed. |
| 126 | Dismantling timber scantlings (framed work) 40 Sqcm and over in section, in any position complete all as specified and as directed. |
| 127 | Dismantling timber scantling under 40sqcm in section unframed work as in fillets, rails, posts, rafters, purlins etc , complete all as specified and directed. |
| 128 | Dismantling of mild steel work of any description all as specified and directed. |
| 129 | Applying 2mm thick wall care putty on internal walls complete all as specified and directed. |
| 130 | Complete removal of existing treatment of old surfaces of walls complete all as specified and directed. |
| 131 | Preparation of old plastered and unplastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and directed. |
| 132 | Preparation of new painted surfaces including complete removal of existing treatment & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered surfaces complete all as specified and directed. |
| 133 | Preparation of old painted surfaces including complete removal of existing treatment & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old prepared surfaces complete all as specified and directed. |
| 134 | Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqcm in width or girth & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:3 including formwork/scaffolding work upto height 7.00mtr above ground level of bldg complete all as specified and as directed. |
| 135 | Vitrified ceramic tiles (light shade) 10mm thick (Square/reactangular) area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 complete all as specified and directed. |
| 136 | Description all as per item No-135 above but in vertical surfaces such as in skirting, dado etc.fixed over and including 10mm thick plaster in CM (1:4), complete all as specified and directed. |
| 137 | 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed in cement and sand mortar 1:4 complete all as specified and as directed. (Size of Kota Stone slab shall be 52 cm x 52 cm). |
| 138 | Machine cut kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar, jointed and pointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete laid over & including 10 mm thick in CM 1:3 screed for laying Kota Stone, complete all as specified and as directed. |
| 139 | Makrana white marble 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including cutting, moulding & polishing laid over & including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 140 | 35mm thick 2nd class hard wood factory made plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board with commercial face veneers fitted to chowkats of size as IS-1003 Part-I, kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 141 | Aluminium anodised sliding door bolts with hasp and stapple extruded section or cast aluminium alloy with length of bolt as 300 mm including fixing bolts complete all as specified and directed. |
| 142 | Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed. |
| 143 | Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue,anodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed. |
| 144 | S&F in Repair 20 mm dia stainless curtain steel rod complete with stainless bracket and side caps fixed in position by drilling holes in wall and fixed the bracket with rawl plug and SS screw all as specified and as directed. |
| 145 | Bituminous mastic filling with 85/25 or 95/10 grade bitumen and coarse sand by mixture 1:3 by weight (comprising of one part of heated bitumen and 3 parts of sand) filling the joints with mastic at the junction of bays of plinth protection to vertical surfaces complete all as specified and as directed |
| 146 | Stainless steel peg set of six with base plate and fixed to wall/door and including rawal plugs/ss screw complete all as specified and directed. |
| 147 | 100mm thick PCC 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) as in sub base of floor/ path incl finishing the surfaces of concrete topping even and rough complete all as specified and as directed. |
| 148 | Pre-polished factory made designer parking tiles (duratuff tiles) of size 300mmx300mmx10-12mm thich with grey cement and pigment jointed and pointed with cement slurry and grey cement over and incl 20mm thich screed bed in CM 1:4 to match the existing shade of tiles complete all as specified and directed. |
| 149 | Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. all as specified and directed, |
| 150 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed. Please Enable Macros to View BoQ information |
| 151 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail