| 1 | Taking down old existing water proofing treament from the top of RCC/arch slab, including demolition of existing PCC padding, plaster, brick bat coba (upto the thicknes of 15cm) and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises. Complete all as specified and directed. |
| 2 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for |
| 3 | M&L cement concrete type B1-1 1:2:4 (using 20mm graded aggregate) as in roof padding, roof/chajjas kerbs or mud stops, rounded or chamfered on edges, haunching etc. finished even and smooth without using extra cement with water proofing compound. Note- WPC shall be paid separately. |
| 4 | Supply only liquid water proofing compound. |
| 5 | Providing and applying HS TPO membrane of 1.2mm thick over the layer of 200gsm Geo-textile with overlap joints of 75mm in both longitudial and traverse direction of the TPO and sealed properly with hot air welding and terminate TPO at the top of parapet wall with termination strip and fix it by screw at 300 mm C/C and sealed with HS jointseal PU on top including surface preparation like remove all loose gravels, dirt, oil, grease and other foreign particles by jet or dry air and clean the surface mechanically or by grinding to make it smooth before application and PCC/cementitious coving of 75mm radius shall be provided at all junction between vertical and horizontal faces before applicaiton of TPO completely as per specificaiton and direction. |
| 6 | Supply and Application of 3 Layer SHR Waterproofing Coating System as per manufacturer application procedure on leaking concrete roof surface by thorough surface preparation with high pressure water jet min. 125 bars, opening the cracks, followed by one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and min. 50% solids, filling and sealing the cracks, then top-coating with 2 Coats of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2500 hrs accelerated durability test and other tests as specified, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 Coats, DFT 120 +/- 20 microns using brush, roller, airless spray gun as applicable. |
| 7 | S&F 1500 litres rotational mouded polyethylene three layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I incl 20 mm bore ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed and incl dismantling of water capacity 1500 litres and Complete all as specified and directed. |
| 8 | S&F 1000 litres rotational mouded polyethylene three layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I incl 20 mm bore ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed and incl dismantling of water capacity 1000 litres and .Complete all as specified and directed. |
| 9 | S & F 25 mm dia GI tubing medium grade with all fittings and fixed to walls and ceiling or laid in floors and incl taking up or down 25mm bore of pipe steel tubing and connections, including cleaning for re-fixing or removal to store and . Complete all as specified and directed. |
| 10 | S & F 40 mm dia GI tubing medium grade with all fittings and fixed to walls and ceiling or laid in floors. and incl taking up or down 40 mm to 50mm bore of pipe steel tubing and connections, including cleaning for re-fixing or removal to store and Complete all as specified and directed. |
| 11 | M&L 100mm thick cement concrete type B-1 1:2:4 (using 20mm graded aggregate) as in platform of water storage tank incl necessary formwork. |
| 12 | Demolition of cement concrete roof facia/chajja (unreinforced) of any description and in any position not otherwise specifically provided for. |
| 13 | M&L RCC (nominal mix) type B-1, 1:2:4 (using 20mm graded aggregate) as in chajjas, roof facia and height of bldg upto 8 m and incl necessary scaffolding. Complete all as specified and directed. |
| 14 | Formwork to chullah hoods, chajjas, troughs and similar items including edges flat rough finished surface of concrete. |
| 15 | M&L for preparation for old concrete surfaces for drilling extra bars suitable for 10mm dia deformed TMT bar upto specified depth including filling with epoxy resin and TMT bar for chajja repair etc Complete all as specified and directed. |
| 16 | Supply only applying nitto bond chemical as per manufacture instruction over demolished surface of old concrete surface complete all as specified and directed. |
| 17 | S&F GI wire netting 0.91 mm dia and 20 mm mesh lathing to wood or metal studding, joists etc in ceiling, stanchions, beams etc including all laps, cutting and waste complete all as specified and as directed. |
| 18 | S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ens and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing clips. |
| 19 | Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc. Complete all as specified and directed. |
| 20 | M&L 12mm thick ready mixed cement plaster in CM 1:3 on wall, chajjas surface (top, bottom and sides), roof facia, hanging facia portion etc upto 6m to 8m height and incl scaffolding. |
| 21 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces upto 6m to 8m height incl scaffolding. |
| 22 | Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of upto 1km from total distance, beyond the lead included in the rates, including loading, unloading and stacking at the destination |
| 23 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 24 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 25 | S&F Fe 410-W (Gde E- 250) quality A Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 26 | Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome |
| 27 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 28 | M&L for pre-cast cement concrete block masonry Type C-I 1:3:6 (20 mm graded aggregate) with solid block ,exc 10cm in width and set in cement mortar 1:6 complete. |
| 29 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm in floors {Superior/Premium quality}, set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 4) complete all specified and directed. Please Enable Macros to View BoQ information |