| 1 | Earth work in excavation of Foundation and plinth in hard soil including dressing and levelling of bed within initial lead of 50mtr.andlifi 1.5mtr etc complete as per the direction of the Engineer-in-charge. |
| 2 | Filling in foundation and plinth with sand including watering and ramming etc complete as per the direction of the Engineer-incharge. |
| 3 | Cement concrite(1:4:8) with 4cm size h.g.b. crusser broken metal of approved quality from approved quarry with ramming watering and curring etc.complete including cost , taxes, royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 4 | Cement concrite(1:2:4) with 12mm size black Crusher broken chips of approved quality from approved quarry with ramming watering and curring etc.complete including supply of all labours, cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 5 | Brick work with KB Brick 25cm x 12cm x 8cm size having croshing strength not less than 100kg/cm2 to149kg/cm2 with dimensional tolerrance± 8% in cement morter (1:6) in foundation and plinth etc. complete as per the Engineer-incharge. |
| 6 | 12mm thick cement plaster in cement morter(1:6)finished smooth to brick work after racking out joints including watering and curring etc.complete including cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-in-charge. |
| 7 | Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling them after 28 days of curing including cost of all materials complete as per direction of Egineer-In-Charge |
| 8 | R.C.C. work in C.C.(1:2:4) including hoisting, laying & curing for 28 days with 12mm size black Crusher broken chips of approved quality from approved quarry with ramming watering and curring etc.complete including supply of all labours, cost.taxes,royality convence charges of all materials to work site,supply of cement T&P required etc.comelete as per the direction of the Engineer-incharge. |
| 9 | Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & tying the grills & placing in position including cost of binding wire 18 to 20 gauge including cost of HYSD steel bar etc. complete. |
| 10 | Cement punning over plastering including watering & curing with cost, taxes, royality & conveyance charges of all materials & supply of all materials & T& P etc complte as per direction of Engineer- in - charge. |
| 11 | Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-incharge. |
| 12 | Wall painting two coats with approved paint over a coat of wall cement primer of approved shade after cleaning the surface with watering, curing, cost, conveyance royalties & taxes of all materials & labour T&P required for the work etc. complete |
| 13 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete. |
| 14 | Fitting of un plasticised 160mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-heat application method including fitting & fixing of required nos. of PVC Teee for outlet & PVC shaddle & PVC raiser, nipple for fitting of air valve, equal Tee etc. complete including conveyance of pipe from factory to work site & testing of pipe line etc complete as per direction of Engineer - in-charge. |
| 15 | Fitting of un plasticised 200mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-heat application method including fitting & fixing of required nos. of PVC Teee for outlet & PVC shaddle & PVC raiser, nipple for fitting of air valve, equal Tee etc. complete including conveyance of pipe from factory to work site & testing of pipe line etc complete as per direction of Engineer - in-charge. |
| 16 | Supply of solvent cement of approve quality for joiniting of PVC Pipe with all cost and all tax etc. complete as per direction of Engineer- in-charge. |
| 17 | Labour charges for Instalation of 10 HP pump Sets including fitting and fixing of base frame, fitting & fixing suction and delivery pipe to motor,NR Valve, Foot valve, Sluice valve and other fitting materials including cutting, welding and etc. including transportation to project site and site clearance etc. complete as per the direction of the Engineer-incharge. |
| 18 | Fabrication of special joint including cutting and welding of pipes out of M.S. pipe / 100mm dia G.I.pipe including welding charges etc. complete. |
| 19 | Construction of outlet at Tank |
| 20 | 100mm. Dia nominal bore G.I.pipe having wall thickness 4.5mm.Elecrical resistance welded.Medium class confirming to IS 1239(Pt-1/2004) with socketed at one end the other end protected with plastic thread protector.The socket confirming to IS-1239 ( pt-I/1992) with latest amendmewnts in random length of 4 to7 mtrs. Each pipe should bear ISI Certfication & manufacturers name/Trade mark including all taxes etc. with guarantee. |
| 21 | Cost of 100mm dia G.I. Bend confirming to IS-1239(Pt-II 1992) including all taxes etc. |
| 22 | 100mm dia C.I. Foot Valve should be of swing type friction less with single disc conforming to IS - 4038/1979 of reputed brand. |
| 23 | 100mm dia G.I.Flange confirming to IS-6392/1971 including all taxes etc. |
| 24 | Monoblock pump set total head of 18 Mtrs capable to discharge 1700 LPM with 10HP/7.5 KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \\"F\\" insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC Power Supply suction delivery= 100mmx100mm with BEE Star rated energy efficiency pump |& as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares. |
| 25 | Supply of 160mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transporation to work site in complete shape and handed over to Pani Panchayat Chairman of Secretary. |
| 26 | Supply of 200mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transporation to work site in complete shape and handed over to Pani Panchayat Chairman of Secretary. |
| 27 | CI double flanged 100mm Non-Return Valve swing type PN-1.0 as per IS:5312 part-I with by pass arrangement. |
| 28 | CI double flanged 100mm dia Sluice Valve |
| 29 | 50MM DIA Air release valve with saddle &Raiser pipe.The air release valve shall confirm to IS14845 with ISImark including all taxes &royality etc. |
| 30 | Cost of 200mm dia PVC Bend ( 90* W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 with latest ammendment. |
| 31 | 200 mm x200 mm x160 mm Ø PVC Tee ( W.P. 4 Kgf/cm2 ) conforming to IS - 4995/ 1988 with latest ammendment. |
| 32 | 200 mm Ø PVC End Cap ( W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 with latest ammendment. |
| 33 | 200 mm Ø PVC Coupler( 4 Kgf/cm2 agricultural PVC fitting ) conforming to IS - 4995/ 1988 with latest ammendment. |
| 34 | 160mm dia PVC Equal Tee |
| 35 | 200X160 mm PVC Reducer |
| 36 | 160mm dia PVC End Cap |
| 37 | 160mm dia PVC Coupler |
| 38 | 5/8 ' x12\\" Nut bolt & washer F.T. for foundation |
| 39 | 5/8 ' x3\\" Nut bolt F.T. |
| 40 | 1/2\\" x2 1/2\\" Nut bolt F.T. |
| 41 | ⅛\\" thick Rubber Insertion |
| 42 | Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST |
| 43 | Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of squirrel cage induction motor up to 10 HP with 16 Amp ( AC - 3 ) duty contactor at 415 volt + 6% - 15 % , 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The starter should provide dependable protection against over load & single phasing fitted with Volt Meter,Ameter,MCB etc.complete including indicator lamp. |
| 44 | 63 Amp. Main Switch Triple pole & natural of voltage range 440 volt of re-wirable fuse and shall confirming to IS-4064(PT-I& ) with ISI mark including all taxes etc. |
| 45 | Base Plate frame for pannel with Mono Block Motor made with 3'' size MS channel having suitable holes for fitting pannel Board and Mono Block Pump Sets from 10 HP to 15 HP). |
| 46 | Moror Hood size (0.45m x0.45m x 0.60m) made with 18 SWG (cold rolled MS sheet with one coat of red oxide primer and two coas of smoke gray/ navey blue enameln both side (inside & outside) suitable to cover cetrifugal monoblock Pump Set from 10HP to 15HP and having provision for attachement with the groves on rear side of the pannel board. |
| 47 | 4 KVR Power shunt capacitor including all taxes and royalities etc. |
| 48 | 3 crorex10mm2 Tarpodar cable XLPE (Cross link polyethylin) confirming to IS-7098(part-II ) including laying below 0.9mtr of the ground and filling the excavated materials including watering and rammin including all taxed etc. |
| 49 | Electrical installation with electrical materials such as PVC tape, Ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, GI flexible conduite pipe, No. 6 GI wire, Copper cable socket, GI socket and flange and petty materials required for electrical installation.All materials should be as per IS |
| 50 | Electrical earthing including all materials as per the direction of the Engineer-incharge |
| 51 | Construction of 3 Phase LT Line |
| 52 | On line DP without AB Switch including cost of all materials, labour transportation,inspection & commissioning etc. complete. Please Enable Macros to View BoQ information |