| 1 | Taking off existing blinds from offices all complete as per direction of Engineer in Charge.Note:- 1. Responsibility of properly taking out , handling, storage will be held with the contractor, nothing extra shall be paid on account of any repair work in blinds (if any).2. If any damage occur to blinds by the act of contractorspersonnel recovery at market rate for the same will be made from contractors bill. |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal ofunserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:(A) Of area 3 sq. metres and below |
| 4 | Dismantling tile work in floors, roofs and walls laid in cement mortar including stacking material within 50 metres lead.A)For thickness of tiles 10 mm to 25 mm |
| 5 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 6 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 7 | Dismantling aluminium/ Wooden/gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed byEngineer-in-charge. |
| 8 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymermodified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form forA) Shelves (Cast in situ) |
| 10 | Edges of slabs and breaks in floors and wallsa)Under 20 cm wide |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fromnatural sources). |
| 13 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red(A) Area of slab over 0.50 sqm |
| 14 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 15 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi- chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in- Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3(ii) Sites with structure height more than 20m for all wind speeds(A)Casement cum fixed panel window having single casement panel at both ends & middle fixed panel withS.S 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles.Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Heightabove 1.8 metre; each openable shutter upto 0.8m width) |
| 16 | Providing and fixing cupboard shutter with 19 mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc. with autoclosing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately) |
| 17 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board andfinished etc. complete as per direction of Engineer-in- charge. |
| 18 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc. all complete.A)100 mm |
| 19 | Providing and laying polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Glazed vitrified floor tiles polished finish of size(A) Size of Tile 600x1200 mm |
| 20 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.A) Size of Tile 600x1200 mm sqm |
| 21 | Providing and laying polished glazed Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to 1S: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints(Payment for grouting of joints to be made separately). (A)Size of Tile 600x1200 mm |
| 22 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987,Non-combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.(a) With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles. |
| 23 | 12 mm cement plaster of mix:(a) 1:4 (1 cement: 4 coarse sand) |
| 24 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately):For fixed portionA) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately): a)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required (Fittings shall be paid for separately).A)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 26 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.a) Pre-laminated particle board with decorative lamination on both sides. |
| 27 | Providing and fixing glazing in aluminium/upvc door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge. (Cost of aluminium snap beading shall be paid in basic item):A)With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 28 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :A) 125x64x2.50 mm |
| 29 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with Si, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mmto 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 30 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.complete. |
| 31 | Providing and fixing aluminium tower bolts, ISI marked (Powder coated) to required colour or shade, with necessary screws etc. complete:a) 150x10 mm |
| 32 | Providing and fixing aluminium hanging floor door stopper, ISI marked transparent or dyed to requiredcolour and shade, with necessary screws etc. complete.A) Twin rubber stopper |
| 33 | Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the Engineer-in-charge.A) Wooven PVC cloth |
| 34 | Providing and fixing roller blinds of fabric 70% PVC, 30% polyster, fabric thickness 0.45 mm, fabric weight 350 gms/sqm, fire resistance, of required shade and including head rails with fixed movement chain, PVC hook, cabs, top channel, bottom roller etc. all complete whenever required as per direction of Engineer-in-charge. (Measurements offabric will be taken only for the purpose of payments).Note:-1. The work under this contract shall be executed in phases / parts, strictly as per the availability of site and instructions issued by the Engineer-in-Charge. The Contractor shall not claim any compensation, idle charges, or damages on account of non-availability of complete site or for execution of work in parts. The sequence and extent of work in each phase shall be decided by the Engineer-in-Charge and shall be binding on the Contractor.2. All activities causing excessive noise, vibration, or disturbance—such as drilling, chiseling, cutting, demolition, grinding, hammering, etc. shall be carried out preferably on holidays, weekends, or beyond normal working hours, as directed by the Engineer-in-Charge. No extra payment shall be made on this account.3. Water charges @ 1 % will be deduct from the bill paid to the agency as water will be supplied by the department only.4. All the malba generated after dismantling/construction at the time of execution of work to be disposed off on per day basis at earmarked location as per the direction of the Engineer-in- Charge i.e. Ground floor, back side of C block at his own expense & nothing shall be paid extra on this account by the Department so that The functioning of the office of Vikas Sadan will not interrupt. Being a headquarter of DDA, if the agency fails to disposed off malba per day then penalty of Rs.1000/- per day will be imposed, to maintain proper working of Offices of Vikas Sadan. |
| 35 | add correction factor of GST @.973 Please Enable Macros to View BoQ information |