| 1 | Civil Work School buildingDismantling old plaster and pointing in cement or lime and raking out joints to 15 mm depth ,watering and Disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 2 | Supplying ,fitting and fixing 38 mm thick good quality well dressed and well seasoned Saal wood Battened shutters,ledged and braced in door, windows or ventilations with oxidised iron fitting such as hinges sliding door ,bolts tower bolts,handles or rings hooks and eyes cleats sand blocks as per schedule taxes position all complete as per building specification and direction of E/I (A) Door |
| 3 | Providing 12 mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 4 | Renewing glass panes,with putty and nalls wherever necessary including racking out the old putty: Float glass panes of nominal thickness 5 mm(weight not less than 12.5kg/sqm) (A)window |
| 5 | Colour one coats of oil bound distemper over old surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales ofsmoke and mosh marks with jhama rugging scaffolding, curing and taxes all complete as per building specification and direction of E/l. |
| 6 | Providing primer one coat of red lead paint of approved make over old wooden surface including preparing the surface after cleaning removing dust,dirt,scales smokes and grease and cleaning the surface thorughly including cost of scaffolding and taxes all complete as per building specification and dircation of E/I Window ,door and ventiletor size Qty both side |
| 7 | Cairrage Of Materialcement |
| 8 | WATER SUPPLY & SANITARY INS AT SCHOOLSupplying and fitting 15mm dia C.P brass bib cock all complete as per specification and direction of E.l. |
| 9 | Providing and fixing G.I pipe complete with G.I fitting and clamps I/C making good the wakk etc. concealed pipe including painting with anticorrosive bitumastic paint cutting chases and making good the wall.15mm dia |
| 10 | 25 mm dia |
| 11 | 32 mm dia |
| 12 | Supplying and fixing gun metal full way valve of approved quality all complete as per specification and direction of E/l. 15mm dia |
| 13 | 25 mm dia |
| 14 | 32 mm dia |
| 15 | Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/l. 15mm dia |
| 16 | Supplying, fitting and fixing 110 mm (4) dia PVC pipes of approved quality and make with IS specification all cost complete as per specification and direction of E/l cost including all labour and materials all complete -3 mtr. Length. |
| 17 | Providing and fixing special type bathroom fittings all complete. 100 mm dia steel jali |
| 18 | Bid cock-Long thread |
| 19 | 32MM dia PVC waste Pipe |
| 20 | Supplying, fitting and fixing PVC water storage tank of approved make and as per IS specification with PCC pedestal all complete. |
| 21 | Supply extra Deep well Hand pump set with All Accessories |
| 22 | Electrial Works For School BuildingWiring for light point / fan point / exhaust fan point / cell bell pont with 1.5 sq.mm F.R PVC insulated copper Conductors singal coore cable in surface / recessed steel conduit with moduler switch moduler plate, suitable GI box and earthing the point with 1.5 sqm FR PVC insulated copper Conductors singal core cable as required Group B |
| 23 | Wiring for light / Power Plug With 2X4 Sq.mm FR PVC Insulater copper conductor singal core cable I surface/recessed medium class PVC conduit alonwith 1 No 4 sq. mm FR PVC insulated copper conductor singal core cable for loop earthing as required. |
| 24 | Supplying and fixing of following size PVC conduit along with accessorisr in surface / Recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 25 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way, Double door |
| 27 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"B\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 28 | Single pole and neutral |
| 29 | Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 30 | Providing and fixing 1200mm Ceiling fan. |
| 31 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 32 | Providing and fixing of LED Bulb - 9/10 watt |
| 33 | Reaparing Work in BuildingDismantling old plaster and pointing in cement or lime and raking out joints to 15 mm depth ,watering and Disposal of unserviceable materials with all leads all complete as per direction of E/I Outer & Inner Both HostelKitchen Room |
| 34 | Providing 12 mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 35 | Colour one coats of oil bound distemper over old surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales ofsmoke and mosh marks with jhama rugging scaffolding, curing and taxes all complete as per building specification and direction of E/l. Both Hostel internal wall 2nd Floor Re plaster Rooms Both side wall Stair Area |
| 36 | Renewing glass panes,with putty and nalls wherever necessary including racking out the old putty: Float glass panes of nominal thickness 5 mm(weight not less than 12.5kg/sqm) window |
| 37 | Colour one coats of oil bound distemper over old surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales ofsmoke and mosh marks with jhama rugging scaffolding, curing and taxes all complete as per building specification and direction of E/l. |
| 38 | Providing primer one coat of red lead paint of approved make over old wooden surface including preparing the surface after cleaning removing dust,dirt,scales smokes and grease and cleaning the surface thorughly including cost of scaffolding and taxes all complete as per building specification and dircation of E/I Door both side (30nosx2=36 |
| 39 | Carriage Of MaterialCement |
| 40 | Water supply HostelS/F/F flat back angular lipped front viterous white glazed earthen urinal of parry, Hindustan or any other I.S.S approved make do.....do.....all complete as per specification and direction of E/l. |
| 41 | Providing and fitting wash hand basin of parry hindustan or any other I.S.S approved make supported on pointed C.l or M.S brackets 32mm spindle stop cock of approved make all complete as per specification and direction of E/l. |
| 42 | Supplying and fitting 15mm dia C.P brass bib cock all complete as per specification and direction of E.l. |
| 43 | Providing and fixing G.I pipe complete with G.I fitting and clamps I/C making good the wakk etc. concealed pipe including painting with anticorrosive bitumastic paint cutting chases and making good the wall.15mm dia |
| 44 | 25 mm dia |
| 45 | 32 mm dia |
| 46 | Supplying and fixing gun metal full way valve of approved quality all complete as per specification and direction of E/l.15mm dia |
| 47 | 25 mm dia |
| 48 | 32 mm dia |
| 49 | Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/l. 15mm dia |
| 50 | Supplying, fitting and fixing 110 mm (4) dia PVC pipes of approved quality and make with IS specification all cost complete as per specification and direction of E/l cost including all labour and materials all complete -3 mtr. Length. |
| 51 | Providing and fixing special type bathroom fittings all complete. 32MM dia PVC waste Pipe |
| 52 | Supplying, fitting and fixing PVC water storage tank of approved make and as per IS specification with PCC pedestal all complete. |
| 53 | Supplying labour tools & equlpments for making grooves in walls all complete job. |
| 54 | Electrial Works Hostel BuildingWiring for circuit / submain wiring along with earth wire with the following sizes of FR PVC insulater copper conductor, singal core cable in surface/recessed steel conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq mm earth wire |
| 55 | 2 x 2.5 sq. mm + 1 x 2.5 sq mm earth wire |
| 56 | Supplying and fixing of following size PVC conduit along with accessorisr in surface / Recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 57 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way, Double door |
| 58 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"B\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 59 | Single pole and neutral |
| 60 | Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 61 | Providing and fixing 1200mm Ceiling fan. |
| 62 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 63 | Providing and fixing of LED Bulb - 9/10 watt |
| 64 | PCC Roadcleaning and grubing road land Rubbing up to a Distance Of 30 M outside Clause 201.(SOR Item No. 2.02) |
| 65 | Compacting original ground supporting Subgrade(Loosening of the ground upto a level of 500 mm below the subgrade level ,watred ,grade & compacted in layer to meet requirement of talbe 300-2 for subgrade construction (SOR item no 3.20 Case (i) case(i)) |
| 66 | Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 Clause 303.1(SoR Item No.3.18(ii)) |
| 67 | Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401(with Grade-iii Material SOR Item no.4.01B(iii)) grading-1 |
| 68 | Providing P.C.C M-200 in nominal mix of (1:1.5:3) in foundation with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of Engineer-in-charge. SOR Item No.12.08(B) Case-ii P.C.C M-20 |
| 69 | Providing shuttring including strutting of deck slab all complete as per building specification and direction of E/I |
| 70 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well waterded ,rammed , fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5M. All compelete as per building specification and direction of Engineer-in-charge. (Mode of measurement compacted volume). |
| 71 | Carriage of Matrials :-Cement |
| 72 | Chips |
| 73 | metal(53mm) |
| 74 | DrainEarth work in excavation in foundation trenches in ordinary soil(Vide classification of soil iteam-A) and disposal of excaveted earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. Abutment |
| 75 | Providing coarse clean sand in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour royalty and taxes all complete as per building specification and direction of E/I |
| 76 | providing Designation 75 B one Bricks flat soling jionts filled with local sand including cost of watering taxes royalty all complete as per building specfiction of E/I |
| 77 | Providing P.C.C M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing, cement, concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I Drain cenal & Drain Top OF wall |
| 78 | Providing designation 100A brick work with fly ash lime brick(FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x 3\\") in C.M. (1:6) in Plinth and Foundation with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.. Drain wall |
| 79 | Providing 12 mm cement plaster (1:6) with 1.5 mm neat cement punning clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. Drain Wall |
| 80 | Carriage of MaterialsCement |
| 81 | Chips |
| 82 | Bricks |
| 83 | High Mast lightSupply of 12 mtr High Mast in one section construction S355 Grade as per BS-EN 10025 top dia 100 mm bottom dia 360 mm plate thickness 3 mm 12 side polygon galvanisestion as per BS EN IOS 1461 base plate dia 520 mm, base plate thickness 25 mm G.I signal spike lighting ptotection maximum wind speed 47mm/s as per IS:875 with 6 nos foundation bolts of PCD 445 mm TS 600/24mm long dia 850mm long luminaries carriage matrials for 40 NB FRW class B M.S pipe dia of carriage ring 450mm with 8 arm welded 2 section light :twin dome aviation obstruction light LED type as required feeder piller control penal housing 32A TPN MCB incomer ,signal dial timer ,25A contactor circuit for automatic control of luminaries outgoing terminal and control circuit for power tool and remole control |
| 84 | For 12 mtr High Mast :ITC of the high mast and light fixture with the help of suitable tools and plants ,wiring of luminaries with all wiring material like PVC insulated PVC sheathed fiexible cable of sitable copper conductor ligs MCB and all labour and construction of shallow foundation with M25 grade concrete for high mast light considering safe soil bearing capacity of 10T/mtrs sq for 12 M high mast |
| 85 | S.I.T.C 240 w led flood lighting luminarie with pressure dia cast housing and toughened glass cover (IP 66 protection) in existing pole / pipe supply voitage 100-270V AC,50 Hz Luminaries shail be confirm to :10322 part -5 / section-5 and shall be complete with all meccessary as required |
| 86 | Laying of one number PVC insulated and pvc sheathed XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including exavation sand cushioning protecting and refilingtje trench etc.as required |
| 87 | Earthing with copper earth plate 600mm x 600mmx3mm yhick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( with charcoal or coke and salt) as required . |
| 88 | Supplying and drawing 4 core 10 sq mm PVC insuiated and scheathed alluminium conductor armoured cable through under ground. |
| 89 | Sign BoardEarth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50M including all lift leveling ramming the foundation trenches, removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I. |
| 90 | Providing coarse clan local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and lifts including cost of all materials labours royality and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 91 | Providing designation 100A brick work with fly ash lime brick(FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x 3\\") in C.M. (1:6) in . brick flate soling joints filled with local sand inculding cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 92 | Providing P.C.C M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm to 6 mm size graded and clene coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing, cement, concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 93 | Providing designation 100A brick work with fly ash lime brick(FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x 3\\") in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.. |
| 94 | Providing and fitting 18 mm thick kitchen platform ----do----e/i |
| 95 | Providing 12mm thick cement p;aster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specifica- tion and direction of E/l. |
| 96 | Add GST @18% |
| 97 | Add Labour Cess @1% Please Enable Macros to View BoQ information |