| 1 | Material Cost (Materials which are shown under erection & which are not shown under material will be supplied departmentally. |
| 2 | Supply of ACSR Zebra conductor as per GTP/specifications |
| 3 | Supply of spacers for Quad ACSR Zebra bus conductor with 250 mm sub-conductor spacing as per GTP/specifications |
| 4 | Supply Tee Connector suitable for Quad ACSR Zebra conductor to Single ACSR Zebra as per GTP/specifications |
| 5 | Supply of spacers for Twin ACSR Zebra conductor with 150 mm sub-conductor spacing as per GTP/specifications |
| 6 | Supply of Tee connector suitable for Quad ACSR Zebra conductor to Twin ACSR Zebra as per GTP/specifications |
| 7 | Supply of Disc insulators ball and socket type, type ‘A’ +B19:B27porcelain type, 90 KN (4 nos. in one string) as per GTP/specifications |
| 8 | Supply of Clamps & Connectors complete in all respect as per scope and Technical Specification for ACSR ZEBRA conductor as per GTP/specifications a) for connecting ACB/CT/PT/LA/Isolator to Single ACSR zebra conductor horizontal approach...408nos b) for connecting ACB/CT/PT/LA/Isolator to Twin ACSR zebra conductor horizontal approach..... 90nos c) for connecting Circuit breaker to Single ACSR zebra conductor Vertical approach...51nos d) for connecting Single ACSR Zebra conductors.....102nos. e) Isolator to Quad ACSR zebra conductor horizontal approach.......24nos |
| 9 | Erection of ACSR Zebra conductor as per GTP/specifications |
| 10 | Erection of spacers for Quad ACSR Zebra bus conductor with 250 mm sub-conductor spacing as per GTP/specifications |
| 11 | Erection of Tee Connector suitable for Quad ACSR Zebra conductor to Single ACSR Zebra as per GTP/specifications |
| 12 | Erection of spacers for Twin ACSR Zebra conductor with 150 mm sub-conductor spacing as per GTP/specifications |
| 13 | Erection of Tee connector suitable for Quad ACSR Zebra conductor to Twin ACSR Zebra as per GTP/specifications |
| 14 | Erection of Disc insulators ball and socket type, type ‘A’ porcelain type, 90 KN (4 nos. in one string) as per GTP/specifications |
| 15 | Erection of Clamps & Connectors complete in all respect as per scope and Technical Specification for ACSR ZEBRA conductor as per GTP/specifications a) for connecting ACB/CT/PT/LA/Isolator to Single ACSR zebra conductor horizontal approach.... 408nos b) for connecting ACB/CT/PT/LA/Isolator to Twin ACSR zebra conductor horizontal approach..... 90nos c) for connecting Circuit breaker to Single ACSR zebra conductor Vertical approach......51nos d )for connecting Single ACSR Zebra conductors.....102nos. e) Isolator to Quad ACSR zebra conductor horizontal approach.......24nos |
| 16 | Dismantling of existing conductor – ACSR Zebra conductor |
| 17 | Dismantling spacers for Quad ACSR zebra bus conductor with 250 mm sub conductor spacing. |
| 18 | Dismantling of Tee Connector suitable for Quad ACSR zebra conductor to Single ACSR zebra. |
| 19 | Dismantling of spacers for twin ACSR zebra conductor with 150 mm sub conductor spacing. |
| 20 | Dismantling of Tee connector suitable for Quad ACSR Zebra conductor to Twin ACSR Zebra. |
| 21 | Dismantling of disc insulators ball and socket type, type ‘A’ porcelain type, 90 KN. (4 nos. in one string) |
| 22 | Dismantling of hardware for Disc insulators ball and socket type, type ‘A’ porcelain type, 90 KN, 3-bolted type. Please Enable Macros to View BoQ information |