| 1 | M & L Double charged Vitrified tiles of size 600 mm x 600 mm 10 mm thick following the specifications as per IS 15622-2006, cut to required size set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles as in floor incl screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying of floor tiles incl dismantling of floor tiles including bedding (but not backing), and rubbish off premises or removed to store complete all as specified and directed. Note : Light Shade/ Dark Shade/ Colour/ Design of the tiles as approved by GE. |
| 2 | M & L Double charged Vitrified tiles of size 600 mm x 600 mm 10 mm thick following the specifications as per IS 15622-2006, cut to required size set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles as in skirting/ Dados incl layer of mortar 10 mm thick in CM 1:4 for fixing of tiles incl dismantling of floor tiles including bedding (but not backing), and rubbish off premises or removed to store complete all as specified and directed. Note : Light Shade/ Dark Shade/ Colour/ Design of the tiles as approved by GE. |
| 3 | M&L FibretteTile of 'Wood fiber Cement Composite '1mm width wood fiber 25 mm thick of size 600x1200mm having excellent noise absorption of 1 NRC as per ISO: 354, Density 400 Kg/ m3, meets Fire Ratings as per BS 476 Part 5,6 and 7 class 1 and P, water resistant and thermal insulated. Installed on G.I studs 600x600mm center to center 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results. including taking down old wall panelling and similar work and removing to store complete all as specified and directed. |
| 4 | Providing & fixing False ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225 : 1987, Noncombustible as per BS tiles 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws incl dismantling of old False Ceiling. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 5 | M&L Modular Brick work with Fly Ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 incl demolition of old brick work or stone/ boulder masonary built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed. |
| 6 | M&L Rendering on fair faces of brick work or concrete surfaces of wall 15 mm thick in CM 1:6 and to be finished even and smooth without using extra cement incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed. |
| 7 | M&L for applying Two coats of oil bound distemper on wall or concrete over a coat of primer over 1 mm thick Wall Care Putty including preparation on newly plastered surfaces complete all as specified and directed. |
| 8 | M&L for applying Two coats of oil bound distemper on wall or concrete over a coat of primer over 1 mm thick Wall Care Putty including completely removing the layer of old surfaces including old puuty work complete all as specified and directed. |
| 9 | M&L for 16 mm thick Granite slab, polished as mirror finish without any hairline crack, as in cooking platforms, steps, window cills, incl proper edge moulding & cutting holes for gas pipe through drill machine and like in cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl dismantling and rubbish off premises or removed to store complete all as specified and directed. |
| 10 | M&L Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth incl taking down old cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed. |
| 11 | M&L for preparation of newly plastered surfaces of ceilings and apply two coats of white wash complete all as specified and directed. |
| 12 | M&L for preparation of old painted surfaces and applying one coat of white wash on ceiling complete all as specified and as directed. |
| 13 | M&L for PCC 1:2:4 type B-0 using 12.50 mm graded aggregate as in sub-base flooring 25 mm thick (levelling course) surface finished even and rough to receive the topping layer incl demolition of old unreinforced sub base pcc complete all as specified and directed. |
| 14 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 15 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed |
| 16 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (108 mm x 52 mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.)Note : Area not exceeding 2.00 sqm each |
| 17 | S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165 incl dismantling wrought iron or mild steel work of any description complete all as specified and directed. (Note :-The rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete) |
| 18 | M & L for preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 19 | M&L Second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. (Note :- The rates include for hardwood and rebated holes for hold fasts, bolts or screws including pelletting to heads.) |
| 20 | S&F Flush shutters 40 mm thick, solid core construction, with particle board core and plywood face panels, both sides face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed. (Note : The rates for flush shutters include for the provision of suitable blocks for taking mortice locks, latches, or other fittings.) |
| 21 | S&F 200 mm Extruded brass handles, fabricated type polished complete all as specified and directed. |
| 22 | S&F 200 mm long Brass barrel tower bolts, but with barrel of extruded section complete all as specified and directed. |
| 23 | S&F 300 mm Extruded brass handles, fabricated type polished complete all as specified and directed by Engr-In-Charge. |
| 24 | M&L Butt hinges, extruded brass with galvanised mild steel hinge pin, anodised and fixed, type C-21 for 125 mm long complete all as specified and directed. |
| 25 | S&F Floor door stopper 150 mm to 250 mm overall length (as approved by GE) of cover plate of of brass body and tongue with hard drawn steel spring , fixed in floor. complete as directed by Engr-in-charge |
| 26 | S&F Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed of 375 mm length of bolt complete all as specified and directed. |
| 27 | Providing and fixing factory made uPVC white colour fixed / louvered ventilator made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.)Note : Area not exceeding 1.00 sqm each. |
| 28 | S&F in repair Brass made Double Curtain Rods 25 mm dia with abstract finial & brackets and globe at the end (as approved by GE) complete all as specified and directed. |
| 29 | S&F 5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. (Note : The Glass may be transparent or tinted as approved by GE) |
| 30 | S&F 5 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 31 | S&F 12 mm thick Toughned glass as in hinged Doors having locking system at the centre and similar work including cutting to shape, drilling holes required, including 400 mm long handles @ each shutter complete all as specified and directed.. (Note : (i) All measurements of cutting shall, unless otherwise stated, include the consequent waste and breakages involved. (ii) The rate includes for any framing required as per site condition.) |
| 32 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates, chains, square bars, cicular bars, etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including dismantling of old railing complete all as specified and directed. |
| 33 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 34 | Taking down ceiling fan/ exhaust fan/ wall fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed. |
| 35 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 36 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 37 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 38 | (a) One light point controlled by one, one way switch 5 Amps |
| 39 | (b) One fan point/ exhaust fan/wall fan point controlled by one, one way switch 5 Amps and regulator |
| 40 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 41 | Description all as per item No 39.00 above but in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 42 | S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 43 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 44 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 45 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 46 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 47 | S&F in repair modular fan regulator switch type 01 module, ISI marked complete all as specified and directed. |
| 48 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 49 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 50 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 51 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 52 | M&L for single pole and earth encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with onesingle pole MCB SP 20 Amps complete all as specified and directed. |
| 53 | S & F for energy efficient exhaust fan of 450 mm sweep heavy duty made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base including writting the MES Number with synthetic enamel paint compelte all as specified and directed. |
| 54 | S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed. |
| 55 | S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal including writting the MES Number with synthetic enamel paint complete all as specified and as directed. |
| 56 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 57 | M&L for LED surface/ceiling fitting 33 to 36 watts, 2 ft x 2 ft fittings suitable for aluminium grid ceiling, lumen out put ≥ 122 lumen/ watt,THD < 10% environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,incl inbuilt drivers suitable for Grid ceiling complete with atration of aluminium frame work wherever necessary during installation all as specified and directed. |
| 58 | S & F for TPN phase segregated distribution board double door vertical type 6 way 415 volts, 50Hz suitable for MCCB incommer IP 43 protection on wall/ floor with necessary cement work and electrical connections complete all as specified. |
| 59 | S&F in repairs MCCB 3 pole 100 Amps breaking capacity 25 KA, Ics = 100% Icu, ISI marked including spreader link & taking down and of the same make as item no. 122, complete all as specified and directed. |
| 60 | Taking down and refixing split type AC any capacity carefully at site all as specified and directed by engr-in-charge. Please Enable Macros to View BoQ information |