| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc., removing materials from site and making good disturbed surface of walls, floors etc complete all as specifed and directed. |
| 2 | M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed for :- |
| 3 | One light point/bell/Fan point controlled by one, one way switch. |
| 4 | One three pin 5 Amp socket on same board with other switches. |
| 5 | One 3 pin 5 Amp socket on independent board. |
| 6 | One light point controlled by two Nos two way switch. |
| 7 | All as per item No. 2.00 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth complete all as specifed and directed. |
| 8 | S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded (FRLS) copper conductor cable of size 6.00 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia or higher PVC non metallic concealed conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor including dismantling of old submain wiring complete all as specifed and directed. |
| 9 | All as per item No 4.00 here-in-before but with 4 Sqmm complete all as specifed and directed. |
| 10 | S&F in repair switch piano flush type 5 amps, single pole one way 240 volts. complete all as specifed and directed. |
| 11 | S&F in repair switch piano flush type 15 amps, single pole one way 240 volts. complete all as specifed and directed. |
| 12 | S&F in repair switch piano flush type 5 amps, single pole two way 240 volts. complete all as specifed and directed. |
| 13 | S&F in repair bell push piano flush type 5 Amp.complete all as specifed and directed. |
| 14 | S&F in repair Socket outlet 3 Pin 5/6 Amp flush type.complete all as specifed and directed. |
| 15 | S&F in repair socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type ISI marked complete all as specifed and directed. |
| 16 | S&F in repair ceiling fan regulator electronic flush , steped (four step) 230 Volts AC complete all as specifed and directed. |
| 17 | S&F in repair ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all as specifed and directed. |
| 18 | S&F in repair door bell ding dong type electric 230 volts AC , single phase, complete all as specified and directed. |
| 19 | S&F in repair lamp holder with 9/11 Watt led bulb PVC/polycarbonate type with back plate complete all as specified and directed. |
| 20 | Supply and fixing in repair LED lights fitting 1 x 16/18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifed and directed. |
| 21 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including street light bracket made of 32 mm GI pipe, 1.2 mtr length fixed with two Nos of clamp, nut and bolts complete all as specified and directed. |
| 22 | S&F in repair MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-42 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB's complete all as specified and directed. |
| 23 | S&F in repair MCB distribution board TPN 4 way, 415 volts, double door, with 200 Amps rated bus bar, neutral bar with shrouds, earth bar, IP-43 , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCBs as incomer and outgoing complete all as specified and directed. |
| 24 | S & F in repair MCB SP, 240 volt, 6 Amp to 30 Amp capacity, 10 KA, 'C' curve complete all as specified and directed. |
| 25 | S & F in repair MCB SPN, 240 volt, 32 to 60 Amp capacity, 10 KA , 'C' curve complete all as specified and directed. |
| 26 | S&F in repair MCB TPN, 415 volt, 63 Amp capacity,10 KA, 'C' curve complete all as specified and directed. |
| 27 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, including dismantling of old earthing complete all as specified and directed. Note : The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |
| 28 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, including dismantling of old earthing complete all as specified and directed. Note : The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |