| 1 | Taking down carefully aluminium/copper point wiring (light,fan,socket or power) of any type complete including fittings and fixtures such as switches,ceiling roses, pendants, holders , sockets, light fittings, removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls/ceiling/floor at various site etc, complete all as specified and directed. |
| 2 | M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed cable in and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed in walls/roof/ ceiling with suitable size of sunk type pressed steel modular terminal box and modular white cover plate with frame of suitable module as per site requirements for mounting of modular switches, sockets, fan regulator etc and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth complete all as specified and directed for the following : |
| 3 | One light point/bell point/ceiling fan/exhaust fan point controlled by one way 5 Amps single pole switch |
| 4 | One 5 pin 5 Amps socket outlet on same board with other switch |
| 5 | One 5 Pin 5 Amps socket outlet on independent board with other switch |
| 6 | One light point controlled by two, 2-way switches |
| 7 | All as per item No 2.00 above but with 2.5 Sqmm cross sectional area electric cable for 15 Amp socket outlet on independent board, complete all as specified and directed. |
| 8 | S&F in repair of modular switch 1 way 6/10Amp , 1 module, complete all as specified and directed. |
| 9 | S&F in repair of modular switch 1 way 16Amp, 1 module, complete all as specified and directed. |
| 10 | S&F in repair of modular switch 2 way 6 Amp, 1 module complete all as specfied and directed. : |
| 11 | S&F in repair of modular bell push, 6 Amp, 1 module, complete all as specified and directed. |
| 12 | S&F in repair of modular socket 6 Amp, 2/3 pin combined 2 module complete all as specified and directed. |
| 13 | S&F in repair of mdoular socket 6 Amp/16 Amp, 2/3 pin combined 2 module complete all as specified and directed. |
| 14 | S&F in repair modular stepped type ceiling fan regulator, 230 volt AC, 2 module, complete all as specified and directed. |
| 15 | S&F in repair modular TV Socket, complete all as specified and directed. |
| 16 | S&F in repair modular Telephone Socket, complete all as specified and directed. |
| 17 | S&F in repair of ceiling rose,surface type bakelite 65x17.5 mm, three terminals, complete all as specified and directed. |
| 18 | S&F in repair of door bell electric, ding dong type, AC 230 volts, single phase, complete all as specified and directed. |
| 19 | S&F in repair in repair lamp holder with 9W LED Bulb PVC/polycarbonate type with back plate complete all as specified and directed. |
| 20 | Supply & fix in repair surface/wall mounting LED batten (1200mm) 20 watt 6500 k Triyca is a 20 W three color CCT change LED batten which can change the color of batten from warm white to natural white to cool white with the help of a simple toggle switch. complete with wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified and directed. |
| 21 | Supply & fix in repair Mirror Light surface/wall mounting LED batten (600mm) 20 watt 6500 k Triyca is a 20 W three color CCT change LED batten which can change the color of batten from warm white to natural white to cool white with the help of a simple toggle switch. complete with wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified and directed. |
| 22 | S&F in repair wall mounted decorative luminarie fitting alongwith 9/10 Watt LED lamp champagne gold finish fixture with plastic body suitable for B22 Base complete all as specified and directed.Make: Havells Cat No LHFOFUE1TZ1W012 or equivalent to Philips/CG |
| 23 | S&F in repair in repair LED light fittings, 10 W bulk head luminaries 230V, 50 Hz complete with all accessories and including connecting up with three core copper conductor cable with suitable size complete all as specified and directed. |
| 24 | S & F in repair Crafted from Aluminum Die Cast with Four-Directional Beam. Its integrated LED ensures long-lasting and energy-efficient with IP65 Protectedcomplete all as specified and directed. |
| 25 | S & F in repair Crafted from Aluminum Die Cast with Two-Directional Beam. Its integrated LED ensures long-lasting and energy-efficient with IP65 Protected complete all as specified and directed. |
| 26 | S&F in repair testing and commissioning energy saving street light luminaire 30 watt LED , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete, IP 66 protection incl connecting with three core copper flexible wire from ceiling rose to connector of light fitting complete alongwith GI Bracket 1.2 mtr made of GI Pipe 32 mm dia suitable for fixing street light on wall alongwith clamps ,nut and bolt all as directed at site all as specified and directed. |
| 27 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling or casing caping for geyser and AC including dismantling of old submain wiring complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 28 | M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, including dismantling of old submain wiring complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length. |
| 29 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections , one twin core cable flat or circular 16 sqmm including taking out old cable complete all as specified and directed. |
| 30 | S & F in repair of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed. |
| 31 | S&F in repair of MCB SPN 10 to 40 Amp capacity, 10KA , 'C' curve complete all as specified and directed. |
| 32 | S&F in repair of MCB SPN 63 Amp capacity, 10 KA , 'C' curve complete all as specified and directed. |
| 33 | S&F in repair of MCB TPN 63 Amp capacity,415 volt complete all as specified and directed. |
| 34 | S&F in repair of MCB TPN 100 Amp capacity, 415 volt, complete all as specified and directed. |
| 35 | S&F in repair in repair MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 8 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. |
| 36 | S&F in repair in repair MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 12 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. |
| 37 | S&F in repair of in repair MCB distribution board triple pole & neutral IP-43 double door metal, 4 way ,415 volt made out of CRCA sheet steel , factory made powder coated with insulated bus bars , shrouded neutral bars, earth bars , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed. . |
| 38 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, including dismantling of old earthing complete all as specified and directed. Note. The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |
| 39 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, including dismantling of old earthing complete all as specified and directed. Note. The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |