| 1 | (SCHEDULE-A PART-I B/R Works)Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site. complete all as specified and directed. |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm eachand n exc 4 sqm and removing from site. complete all as specified and directed. |
| 3 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles. complete all as specified and directed. |
| 4 | Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided complete all as specified and ditrected. |
| 5 | Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion complete all as specified and directed. |
| 6 | Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. complete all as specified and directed. |
| 7 | S&F Pressed steel frames of size 125 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed. |
| 8 | S&F Pressed steel frames of size 105 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed. |
| 9 | S & F for 35 mm thick factory made, 2nd class hard wood glazed and skeleton shutters open rebeated and prepared to received glass, gauzed, with out sash bar edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of member of shutter as per specified in SSR Part-I Section 8, clause 8.24 (a) and for door and fixed with chowkats, chemically pressure treated complete all as specified and as directed. |
| 10 | S&F for 35mm thick 2nd class hard wood plain, framed pannelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board wiyh commercial veneering on both faces. The size of rail and stile as per (IS : 1003 part-I , kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 11 | S&F for steel ventilators with top fixed type, with glazing bars complete welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed (Note :- Glass shall be measured and paid for separately). Please Enable Macros to View BoQ information |
| 12 | S&F for steel ventilators with top fixed type, with glazing bars complete welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed (Note :- Glass shall be measured and paid for separately). Please Enable Macros to View BoQ information |