| 1 | Supply, installation, testing and commissioning factory made, outdoor type panel, made out of 3.00 mm thick MS powder coated, weather, dust & vermin proof with suitable size angle iron frame fixed on raised PCC platform including control wiring with suitable copper wire and locking arrangement including suitable working space for Automatic micro Processor based energy monitoring system for upto 1000 KVA, 11 KV transformer via V sat satellite Controlled Data communication out put pot with following features complete all as specified and directed:- (A) Automatic monitoring of electrical data parameters of LT side of Transformer Load /Voltage of each phase communication pot . (B) Sending ringer tone based alert with voice calling with nature of fault to 5 mobile nos and with alpha numatic Alert with alert value and location with date and time to 5 mobile nos for high loading perameters of transformer on pre-defined numbers with 12 parameters of transformer out put communication pot via Vsat satellite controlled data transmitter panel as mentioned below:-i) High voltage R Phaseii) High voltage Y Phaseiii) High voltage B Phaseiv) High current R Phasev) High current Y Phasevi) High current B Phasevii) MCCB-1 Tripviii) MCCB-2 Tripix) MCCB-3 Tripx) MCCB-4 Tripxi) Transformer body Temperature Highxii) Oil Level Empty (C) Satellite Vsat controlled out put data pot for transmition of transformer energy data to control room For record generation with live graphical trends for current peak load on each phase for load balancing / high voltage / high temperature of transformer.(D) Live data monitoring at an interval of 60 seconds via Satellite Vsat controlled data transmitter.(E) Inbulit Data storage for at least Two year.(F) With LCD Display(G) Energy Parameters such as frequency, 3 Phase Voltage, current, Power factor, KVA, KVAH, KW and KWH can be monitored from the central control room. |
| 2 | (H) Automatic monitoring of electrical data parameters for transformer upto 1000 KVA.(J) All the electrical and alarm data can be printed in EXCEL Format for report generation with date and time for weekly/monthly/yearly. Note : All Vsat data transmission are free of cost to department for 10 years. MoU in this regard to be submitted from OEM without any extra charges.Make :- Unison Engg Enterprises/Rockwell automation(Allen Bradely)/megha automation/Siemens |
| 3 | Supply, installation, testing & commissioning of CTs upto capacity 1400/5 or suitable for transformer upto 1000 KVA capacity complete all as specified and directed (Set of three) including the Supply ,installation, commissioning and testing of Desk top Computer of Core i5,8 GB RAM, SSD 500GB, Windows 11 , with monitor of 23 inch with SCADA software compatible Make Dell/HP/ Lenovo/Intel with 1 KVA UPS of make :- Microtech, Sukam, Exide, Luminous /Amron/ Dell/with Printer suitable for A4 size paper B & W Make: HP/ Canon/Epson With VSAT to Wi-Fi Micro controller controlled Modem make :- Unison Engg Enterprises/Rockwell Automation/ Megha Automation . |
| 4 | Supply, installation, testing & commissioning of CTs upto capacity 700/5 or suitable for transformer upto 500 KVA capacity complete all as specified and directed (Set of three) of Make:- AE/UEE/DELTA. |
| 5 | All as per item no 3.00 here-in-before-but CTs upto 560/5 complete all as specified and directed (set of three).Make:- AE/UEE/DELTA |
| 6 | All as per item no 3.00 here-in-before-but CTs upto 140/5 complete all as specified and directed (set of three).Make:- AE/UEE/DELTA |
| 7 | Supply, installation, testing & commissioning of micro chip type temperature sensor suitable for transformer upto 1000 KVA capacity complete all as specified and directed Make :- Unison/crystal/select. |
| 8 | Supply, installation, testing & commissioning of SS type oil level Magnetic sensor with ss float for monitoring oil level in conservator tank of transformer upto 1000 KVA capacity complete all as specified and directed of Make :- Unison/crystal/select. |
| 9 | Supply, installation, testing and commissioning factory made, outdoor type panel, made out of 3.15 mm thick MS powder coated, weather, dust & vermin proof with suitable size angle iron frame fixed on raised PCC platform including control wiring with suitable copper wire and locking arrangement including suitable working space for V-sat satellite Controlled transmitter with inbuilt micro chip antenna to be installed at Automatic micro Processor based 11 KV Transformer energy monitoring panel of capacity upto1000 KVA to transmit Energy monitoring data to control room via Vsat Satellite controlled High power transmitter and to transmit Transformer 12 alert via Ringer tone based alert with voice calling with nature of fault to 5 mobile nos and via Vsat Controlled alpha numeric based alert with alert value of fault to pre-defined 5 mobile numbers with area code with date and time to 5 mobile , wiith SMPS power supply complete all as specified and directed. Note: All Vsat data transmission are free of cost to department for 10 years. MoU in this regard to be submitted from OEM without any extra charges. Make :- Unison Engg Enterprises/Rockwell automation(Allen Bradely)/megha automation/Siemens |
| 10 | Supplying & Fixing on wall / laying in ground 6 X 1.5 Sqmm PVC insulated Copper armoured cable with heavy duty PVC Saddles 60 cm apart complete all as specified and directed by Engineer-in-charge. Make: Grandlay/Gloster/Polycab |
| 11 | All as per item no 09.00 here-in-before-but 4 x 1.5 Sqmm PVC insulated copper armoured cable. Make: Grandlay/Gloster/Polycab |
| 12 | All as per item no 09.00 here-in-before-but 2 x 1.5 Sqmm PVC insulated copper armoured cable.Make: Grandlay/Gloster/Polycab Please Enable Macros to View BoQ information |