| 1 | Please Enable Macros to View BoQ information |
| 2 | S&F 5mm thick hollow PVC panels for ceiling with EPS stuck to 0.60mm plain PVC sheet suitably placed including false ceiling grid made of GI with parameter of wall support channel size of 25 mm, inner centre frame support channel size 50mm and section for panel support channel size 75mm as per specification same as waiting area at PUPSA HQ Colour texture and pattern of ceiling should be fixed including aluminium hollow pipes of appropriate size to support the ceiling as per the direction of Engr-in-charge/GE, complete all as sepecified and directed. |
| 3 | S & F in 10 to 12 mm thick toughned glass as in fixed glass, hinged doors, partitions, automatic doors, sliding door, windows and similar work including cutting to shape, drilling holes, including single leg spider, ceiling/bottom to glass connector and pivots, glass to glass connector, stabilizer rod, floor clamp, plastic parts, wall to glass hinge, knob, roller, Sliding Channels and all necesaary fittings, floorspring (With S.S. Cover), C Shape Square SS Handle - 450mm, Locking Arrangement etc. all fittings for doors/partitions (including SS fittings) required to make functional all as specified and directed |
| 4 | M&L for fabrication and fixing BWP (Boiling water Proof) solid block Board 19 mm thick conforming to IS 1659- 2004 to be used ,inside depth not less than 0.50 metre. All the exposed surface which are or can be visible to be covered with 1.0 mm th. Sunmica of Approved colour, shade and finish. The surface which will come in contact with wall/ masonary/tiles etc shall be premiered with Appropriate Wood primer mixing Approved Antitermite chemical and pasting 250-micron water proof Plastic Sheet with appropriate adhesive. All the Pastings to be done with water resistant Adhesive. Any Butt joint should be strengthen with Screw and Fissures inserted with appropriate pasting compound. Shutters of storage unit to be formed out of 19 mm thick BWP ply and faced with 1.0 mm thick Sunmica. Provide shelf etc. made of 19 mm thick BWP B.B., polished to engineer-in-charge's approval. Complete Including with all necessary fittings like knobs, magnet catcher, running track for sliding, hinges any type, ball catchers, SS tower bolts 150mm , locks,SS handles 300mm long, adjustable shelves etc. as per directions of Engineer Incharge. Inside surfaces to be finished with 1.00 mm thick Sunmica and outer exposed surface with 1.00 mm th. Sunmica. Cupboard depth of 600- 750 mm. (Note: 1.Rates inclusive of solid block board, adhesives, fittings/fixtures, Sunmica and plastic sheet etc and shall not be paid separately. 2.Front facing area shall only be considered for payment complete all as sepecified and directed. |
| 5 | Supply and fixing factory made Two track two shutter sliding window with frame ( Colour of frame - Black/white/brown and texture as per the direction of Engr-in -charge /GE ) & 5.5 mm thick glass (As approved by GE) panes fixed (Two nos. glazed ) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 (+) (-) 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension uPVC white colour sliding glazed window comprising uPVC multi chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 (+) (-) 0.2 mm thick alvanized mild steel section made from roll forming porcess of required length (shape & size according to uPVC profile) including appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing grame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Rate inclusive of (Single/ double glass panes, wire mesh and silicon sealent and shall not be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made complete all as sepecified and directed. |
| 6 | S&F Factory made UPVC Collapisable mesh system for doors/windows/any opening, featuring high quality UPVC Profiles for frame and housing ( colour of frame as per the direction of Engr-in-charge/GE), Mesh Material should be high strength non corrosive stainless steel (SS 304 or 316 ) or Fibre mesh in pleated/collapsoble form, mechanism should be smooth sliding in vertical/horizontral folding with tension cord for stability, Frame should be multi chambered UPVC Profile ( approx 30 mm X 70 mm or similar ) with necessary sliding track including magnetic closing strip,rollers,guide rails,handles,EPDM gaskets and GI Fastners for fixing to wall/ any other surface, complete all as specified and dirceted. |
| 7 | Providing and fixing sand stone (Colour as approved by GE) cladding in (wall lining) any shape at all heights with 18 to 20 mm thick gang saw cut stone with (machine cut edges) of uniform colour and size, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with adhesive (not to be paid separately) in proportion as per manufacture's specification, including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade at all levels including cutting, making recesses in stone slab, drilling holes, rubbing, polishing, curing, and scaffolding etc. complete all as specified and directed |
| 8 | M&L for ultra charged vitrified tiles 10-15mm thick (or thickness as specified by manufacture), (square/ rectangular) polished, area of each tiles exceeding 0.36 Sqm (including 2400mmx800mm size) but not exceeding 2 Sqm in flooring set and jointed in premium epoxy grout (Kajaria KE-100 or equivalent) to match the colour of tiles and including bedding of average thickness 6mm thick premium tile adhesive kajaria CX-1 or equivalent for laying of tiles on brick/concrete surface complete all as specified and directed. (Note: Rates Inclusive of Premium epoxy grout, premium tile adhesive and shall not be paid separately). |
| 9 | M&L for Screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed |
| 10 | M & L for 75 mm thick Plain cement concrete 1:3:6 type C-2 using (40 mm graded stone agg) as in sub base complete all as specified and directed. |
| 11 | M&L for hardcore of broken bricks gauges n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 12 | M&L for premium quality wallpaper of Nilaya Asian paint, Marshall's wallcovering, D'decor, Elementto or equivalent fixed with adhesive over the finished wall surfaces in required colour / shade as complete all as specified and directed. (Note: Rates inclusive of adhesive) |
| 13 | S & F for Steel work in tubular trusses etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 14 | M&L for Rendring 15 mm thick on fair faces of brick work on wall surfaces in CM 1:4 finished even and smooth without using extra cement Complete all as specified and directed |
| 15 | M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including 2 mm thick wall care putty over new surfaces using roller for painting complete all as specified and directed. |
| 16 | M&L for brick work with sub class fly ash bricks straight or curved on plan exc 6 m mean radis built in CM 1:6 complete all as sepecified and directed. |
| 17 | M&L for 18-20mm thick granite stone slab ( colour and texture as per directed by Engr-in-charge ) machine cut in cooking platform, jams, pillars, windows cills, top of shleves and the like laid over and including 15mm thick screed bed or backing coat in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding, bull nosing and polishing complete all as specified & directed. |
| 18 | S&F mild steel TMT bars No 500D 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing clips complete all as specified and directed. |
| 19 | All as described ser item no 17.00 here-in-before but 6 to 8 mm dia complete all as specified and directed. |
| 20 | M&L for RCC design mix M 25 ( using 20 mm graded stone aggregate) as in roof slabs supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 21 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete complete all as sepecified and directed. |
| 22 | M&L for Ceramic glazed wall tiles including designer/digital/HD/Polished tiles (thickness as specified by the manufacturer), area of each tiles exceeding 0.18 Sqm but not exceeding 0.72 Sqm in flooring set and jointed in premium epoxy grout (Kajaria KE-100 or equivalent) to match the colour of tiles and including laying over cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness bedding on brick/concrete surfaces complete all as specified and directed. (Note: Rates Inclusive of Premium epoxy grout, premium tile adhesive and shall not be paid separately) over and including 10 mm thick screed bed for fixing floor tile complete all as specified and directed. |
| 23 | M&L for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, unsheathed, multistranded, flexible,copper conductor cable 1.5 sqmm,1100 volts grade drawn through and including in PVC conduit of size 25 mm or above as required at site with all accessories such as Tee,corner, overlaping connector etc.on surface walls, roofs and ceilings etc. including concealed MS box factory made of suitable size fabricated out of 1.2mm thick MS sheet/modular plate and frame suitable for mounting switches, sockets, fan regulators etc.and including 1.5 Sqmm PVC insulated, multistranded, unsheathed(Green colour),FRLS type single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for One light point / fan point controlled by one switch complete all as specified and directed. |
| 24 | All as described item ser no 22.00 here-in-before but for One 3 pin 6 amps socket out let point controlled by one 6 amps switch on independent board complete all as specified and directed. |
| 25 | All as described item ser no 22.00 here-in-before but for One 3 pin 6 amps socket point controlled by one 6 amps switch on same board complete all as specified and directed. |
| 26 | M&L for each additional light point with 1.5 sqmm copper conductor on the same switch circuit, complete all as specified and directed. |
| 27 | All as described item ser no 22.00 here-in-before but with 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switch on on same board complete all as specified and directed. |
| 28 | S&F modular switch 10 Amps, one way, one module complete all as specified and directed. Make Havells (wooden finish) or equivalent to L&T and Indoasian complete all as specified and directed. |
| 29 | S&F modular switch 20 Amps,one way, one module complete all as specified and directed. |
| 30 | S & F modular socket 10 Amps, 2/3 Pin combined, two module complete all as specified and directed. |
| 31 | S&F in repairs modular socket 6 A/16 Amps, 6 Pin combined, two module complete all as specified and directed. |
| 32 | S&F 5 w round LED surface dowlighter ,striker surface under cabinet LED light complete all as specified and directed. |
| 33 | S&F profile light LED Strip aluminium channel 25 mm rectangular surface channels with difusssed cover, end caps mounting clips including driver, complete all as specified and directed. |
| 34 | Supply & fix antique metal single light hanging, with adjustable chain hieght , Inside Amber Glass with E27 filamnet bulb vintage decorative for outdoorn and indoor, complete all as specified and directed. |
| 35 | S&F 3 in 1 multicolour 15 Watt LED flush / surface/reccesd mounting down light luminaire powder coated finish in round or square shape with integral electronic driver THD<10% complete all as specified and directed.. |
| 36 | S&F MCB distribution board SPN 4 way 240 volts, single door with IP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete all as specified and as directed. |
| 37 | S&F MCB SP 6 to 32 Amps,10 KA, \\"C\\" series, 240 volts complete all as specified and directed. |
| 38 | S&F MCB SPN 40 to 63 Amps 10 KA, \\"C\\" series, 240 volts complete all as specified and directed. |
| 39 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections complete all as specified and directed. |