Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceding 30cm in depth.1.5m in width as well as 10 sqm on plan) including dressing of …...by mechanical means):- All kinds of soil |
| 2 | Supplying and filling in plinth withcrusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete.Note: - Maximum thickness of this layer shall be 20 cm. |
| 3 | With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) |
| 4 | Providing and laying in position cement concrete of specified grade cxlusing the cost of centering and shuttering - All work up to plinth level :- With 20mm nominal size graded stone aggregate. :-M 15- Grade concrete |
| 5 | Providing and laying in position cement concreteof specified grade excluding the cost of centering and shuttering - All work upto plinth level :With 40mm nominal size graded stone aggregate. M-15 - Grade concrete |
| 6 | Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominalsize graded stone aggregate.) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone….finishing and reinforcement- All work up to plinth level :- M 20-Grade Concrete |
| 8 | Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or moreconforming to IS 1786 |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for :- Foundations, footings, bases of columns, etc. for concrete up to plinth level |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for :- Walls (any thickness) including attached pilasters butteresses, plinth beams and string courses etc. up toplinth level |
| 11 | Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone….finishing and reinforcement- All work above plinth level :- M 20-Grade Concrete |
| 12 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate)in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement inconcrete grade. M-20 Grade Concrete |
| 13 | Suspended floors, roofs, landings, balconies and access platform. |
| 14 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for :- Columns, Pillars, Piers, Abutments, Postsand Struts. |
| 16 | Weather shade, Chajjas, corbels etc., including Edges. |
| 17 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : Having 50 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand) |
| 18 | Half brick masonry with fly ash lime Gypsum bricks (FALG bricks) conforming to IS: 12894, in super structure above plinth and upto floor two level. Having 50 kg/cm2 average compressive strength. Cement mortar 1 : 4 (1 cement : 4 sand) |
| 19 | Extra for providing and placing in position 2 Nos. 8mm dia. M.S.bars at every third course of in half brick masonry. |
| 20 | 12 mm cement plaster of mix :1:6 (1 cement : 6 sand) |
| 21 | 15 mm cement plaster on rough side of single or half brick wall of mix ::-1:6 (1 cement: 6 sand) |
| 22 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) |
| 23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. |
| 24 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 grams/ltr of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coat on new work. |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on newwork. |
| 26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed tosteel windows by welding. |
| 27 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved..architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 28 | For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).Powder coated aluminium (minimum thickness ofpowder coating 50 micron) |
| 29 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprenegasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) |
| 30 | Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3mm and nuts and bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. |
| 31 | Filling the gap in between aluminium frame and adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5 mm depth and 5mm width |
| 32 | Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and category withproperty of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately) Single rebate (75 mm X50 mm) |
| 33 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice.husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter |
| 34 | Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm pressed mild steel welded or rigidly fixed together by mechanical means, including 2.5mm thick M.S. pressed butt hinges, with mortar guards, lock strike-plate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre- treatment of the surface as directed by Engineer-in charge: Profile C of 1.60mm thick single rebate of size 100mmx50mm Fixing with adjustable lugs with split end tail to each jamb. |
| 35 | Providing and fixing ISI marked factory made flush door shutters conforming to IS: 2202(Part-I) laminated type, core of block board construction with kiln seasoned and chemically treated 2nd class hard wood battens (strips) and frame of kiln seasoned and chemically treated, finger jointed 1st class hard wood of width not less than 65mm for style, top rail, bottom rail and 125mm for..with IS: 2202. The rate shall be inclusive of all material and labour complete and as per specification and dirction of Engineer-in-Charge. 35mm thick including 4 nos. 100mm long, ISI marked heavy weight (2.5mm thick) Stainless steel butt hinges with necessary screws. |
| 36 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutterto be measured) : Rectangular or square. |
| 37 | Providing and fixing ISI marked stainless steel sliding door boltswith nuts and screws etc. complete:300x16 mm |
| 38 | Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm |
| 39 | Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : 125 mm |
| 40 | Providing and fixing Stainless steel hanging type floor doorstopper with necessary screws, etc. complete. |
| 41 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete. |
| 42 | Supplying and fixing rolling shutters of approved make, made of required sizeM.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufacturedfrom high tensile steel wire of adequate strength conforming to I.S. 4454- part-1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover. |
| 43 | Extra for providing suitable mechanical device chain and crank operation for operating rolling shutters. Exceeding 16.80 sqm inarea. |
| 44 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-Charge. (Area of grill to be measured). |
| 45 | Providing and fixing ball bearing for rolling shutters. |
| 46 | Providing for plaster drip course/ groove in plastered surface ormoulding to R.C.C. projections. |
| 47 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 sand) as per standard design : In 75x75mm deep chase |
| 48 | Making khurras 45x45 cm (sunk area) with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete so as to receive rain water/ spillage water on roof in a sunk area and completely rain out in a near perfect strain meter motion into rain water pipe. |
| 49 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish wherever required etc. complete at all levels. Samples approved by Engineer-in-Charge. Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black |
| 50 | Granite fine grained dark crystal of other colours and variouspatterns |
| 51 | Providing and laying gang saw cut 18 mm thick, mirror polished premoulded (wherever required) and pre polished machine cut granite stonework in flooring of required size shape of approved shade, color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-in-Charge. Area of slab over 0.50 sqm Fine grained granite dark Black/dark Red/ Whiteor equivalent with self design/ pattern/crystals of other colors of glitter |
| 52 | Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbingand polishing of cut edges etc. complete. |
| 53 | Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than0.05% and conforming to IS:15622 of approvedmake in all colours& shades, quality/ premium quality in flooring laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete In light shade glossy/ rustic /stain finishedSize 600X600 mm thickness 9-10 mm |
| 54 | Providing and laying vitrified floor tiles Multi/Double charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades,1st quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4(1cement :4sand) including grouting the joints with white cement and matching pigments etc. complete In light shade glossy/ rustic /stain finished (a) Size 600X600 mm thickness 9-10 mmSize 600X600mm thickness 9-10mm |
| 55 | Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (having thickness 9 to 10mm) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 20mm thick cement mortar 1:4 (1 Cement : 4 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 56 | Providing and laying rectified Glazed Ceramic wall tiles 300x450 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours white, ivory, grey, fume red brown laid on 12 mm thick cement mortar 1:3 (1 Cement : 3 sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 57 | Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement with matching pigments etc.,complete. |
| 58 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete with base of cement mortar 1 : 4 (1 cement : 4 sand) 25 mm thick.(Area of slab to be over 0.25 sqm) Note: - Deduction shall be made for not mirror polishing according to item no 11.43 |
| 59 | Kota stone slabs in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishingcomplete. 20 mm thick |
| 60 | Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washersetc. complete. Hot finished welded type tubes |
| 61 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in- charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 |
| 62 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-Gutter. (600 mm over all girth) |
| 63 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 64 | Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 65 | unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend (minimum wall thickness 2.2mm) |
| 66 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plasticseat and lid. |
| 67 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. |
| 68 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : Oval shape wash basin over counter /under counter with 15 mm C.P brass pillar tap (Counterto be paidsepratly). |
| 69 | Providing and fixing C.P. brass bib cock of approved qualityconforming to IS: 8931, 15 mm nominal bore. |
| 70 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mmnominal bore. |
| 71 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mmnominal bore |
| 72 | Providing and fixing C.P. brass pillar cock approved qualityand make conforming to IS: specification. 15 mm nominal bore 125 mm long foam flow. |
| 73 | Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washerscomplete. |
| 74 | Providing and fixing CP brass waste coupling of approved qualityand make for sink and wash basin. Waste coupling 38mm of 83mm length and 77mm breadth |
| 75 | Providing and fixing CP brass bottle trap of approved quality andmake for sink and wash basin. |
| 76 | Providing and fixing CP brass towel rail of approved quality andmake 600x20mm |
| 77 | Providing and fixing C.P. brass soap container 109 mm wide, 125 high and 112 mm distance from wall of standard shape with bracket of the same material with all fittings etc. of approvedquality and conforming to IS: specification. |
| 78 | Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) 110 mm diameter |
| 79 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion...Coupler 110 mm |
| 80 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion....Pushfit Coupler...110 mm |
| 81 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .Single tee with door...110x110x110 mm |
| 82 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion...Single tee without door..110x110x110 mm |
| 83 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion...Bend 87.50..110 mm bend |
| 84 | Providing and fixing Unplasticised - PVC pipe clips of approved design to Unplasticised - PVC soil and waste pipes by means of bombay nail of required length including and making good thewall etc. complete. 110 mm |
| 85 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 86 | Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 87 | Providing and fixing C.P. brass grating of approved quality andmake conforming to IS: specification. 110 mm dia |
| 88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge....Concealed work includingcutting chases and making good thewalls etc. 15 mm nominal outer dia .Pipes. |
| 89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge....Internal work - Exposed onwall 32mm nominal outer dia.Pipes. |
| 90 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge....40mm nominal outer dia.Pipes. |
| 91 | Providing and fixing uplasticised PVC connection pipe with brassunions : 45 cm length 15 mm nominal bore |
| 92 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 93 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stoneaggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep includingC.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With well burnt bricks |
| 94 | Providing and fixing square- mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tightC.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design : 150 x 100 mm size P type. Withwell burnt bricks |
| 95 | Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) upto haunches ofS.W. pipes including bed concrete as per standard design :...100 mm diameter S.W. pipe |
| 96 | Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) upto haunches ofS.W. pipes including bed concrete as per standard design :..150 mm diameter S.W. pipe |
| 97 | Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly....110 mm diameter OD (min. wall thickness 3.2mm) |
| 98 | Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly.....160 mm diameter OD (min. wall thickness 4.0mm) |
| 99 | Point wiring (excluding metallic switchbox & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :-...Light point/fan points...Primary short point |
| 100 | Point wiring (excluding metallic switchbox & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :-...Light point/fan points....Primary medium point |
| 101 | Point wiring (excluding metallic switchbox & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :-...Light point/fan points.....Primary long point |
| 102 | (Light point/fan points) loopingpoint...Secondary short point |
| 103 | (Light point/fan points) loopingpoint…..Secondary medium point |
| 104 | (Light point/fan points) loopingpoint….Secondary long point |
| 105 | 3 Pin 6 Amp socket outlet onseparate board (Normal and UPS sockets for computers)...Short point |
| 106 | 3 Pin 6 Amp socket outlet onseparate board (Normal and UPS sockets for computers)….Medium point |
| 107 | 3 Pin 6 Amp socket outlet onseparate board (Normal and UPS sockets for computers)…...Long point |
| 108 | Twin control light points…...Long point |
| 109 | Point wiring (excluding metallic switchbox & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigidP.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specificationon same board. |
| 110 | Wiring for circuit wiring with PVCinsulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification 2x2.5 Sq.mm. |
| 111 | Point wiring (excluding metallicswitch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-On separate board....Short point |
| 112 | Point wiring (excluding metallicswitch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-On separate board....Medium point |
| 113 | Point wiring (excluding metallicswitch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq.mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-On separate board....Long point |
| 114 | Same board switch & socket 16Amp./S.S. combined 20/16/6 Amp |
| 115 | PVC conduit 25 mm. (MMS) |
| 116 | Supply and fixing PVC conduit ISImarked FRLS along with the accessories in concealed system etc. as required….PVC. conduit 20 mm (HMS) |
| 117 | Supply and fixing PVC conduit ISImarked FRLS along with the accessories in concealed system etc. as required…...PVC. conduit 25 mm (HMS) |
| 118 | Supplying and fixing of approved makemodular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-3 Module metal box |
| 119 | Supplying and fixing of approved makemodular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-4 Module metal box |
| 120 | Supplying and fixing of approved makemodular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-6 Module metal box |
| 121 | Supplying and fixing of approved makemodular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-8/9 Module metal box |
| 122 | Supplying and fixing of approved makemodular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-12 Module metal box |
| 123 | Supplying and fixing of approved makemodular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-18 Module metal box |
| 124 | Supplying and drawing single core PVCinsulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification…..1 X 2.5 sq. mm. |
| 125 | Wiring for sub-mains with PVC insulatedcable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) FRLS ISI marked of suitable size (conduit included) including2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of ConduitWiring Point No.11)4 Wire sub main.....6.0 sq. mm. cable |
| 126 | Wiring for sub-mains with PVC insulatedcable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) FRLS ISI marked of suitable size (conduit included) including2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of ConduitWiring Point No.11)4 Wire sub main......10.0 sq. mm. cable |
| 127 | Supplying of approved make TPN MCB DBmetal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator):4 Way (8+12) |
| 128 | Supply of ISI marked and accepted standardof miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-Single pole...MCB SP 6Amp to 32Amp 10kA rating |
| 129 | Supply of ISI marked and accepted standardof miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-Single pole.....MCB FP For 40Amp 10kA rating |
| 130 | Fixing of MCB/MCCB/Isolator in sheet steelenclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only)..MCB/Isolator SP/DP |
| 131 | Fixing of MCB/MCCB/Isolator in sheet steelenclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only)...MCB/MCCB Isolator TP/TPN/FP |
| 132 | Supplying, erection and testing of approvedmake electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments....Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min andservice value ≥ 4.00 as per BEE.. |
| 133 | Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70.Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/cconnection wire, testing etc. to complete the job. Tube light LED 1 X 20/22Watt, Integral i/cbatten aluminium body, PC diffuser. |
| 134 | Supply and fixing surface mounting LED downlighter, LED of 1 to 3Watt each assembled on single MCPCB, having color temp upto 6500K& having 50000 burning hrs. life with minimum@ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/cconnection wire, testing etc. to complete the job.. 14/15 Watt, color temp 3000-6500k as required. |
| 135 | Supplying, fixing and testing of approved makeLED bulkhead ABS body, PC diffuser including fixing on wall as required, with necessary material complete10W IP 55 |
| 136 | Providing and fixing circular/hexagonalcast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by mean of3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of12mm dia M.S. bar bent to shape as per standard drawing. |
| 137 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor4 core armoured 16 sq. mm. (External DB Incoming cable from the nearest building) |
| 138 | SPLIT AC (inverter model) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to 50 deg. C & heating within 0 deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of samemake (brand)....1.5 TR Star rating 5 star Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail