| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 15m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 4 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Cold twisted bars |
| 10 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes |
| 11 | Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texturem in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. With granite stone of area less than 0.50 sqm. |
| 12 | Providing and fixing bolts including nuts and washers complete. |
| 13 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 14 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 15 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 16 | Manufacturing, supplying fixing retro reflective overhead signage boards & removing of existing damaged retro reflective made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in- charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signage, |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 18 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 19 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 20 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand |
| 22 | Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 24 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 25 | Washed stone grit plaster on exterior walls height upto 10metre above ground level,in two layers,under layer12mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool,applying cement slurry on the under layer @ 2 Kg of cement per square metre, toplayer 15mm cement plaster 1: 1/2:2 (1cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size), inpanels with groove all around as per approved pattern,including scrubbing and washing the to player with brushes and water to expose the stone chippings,complete as per specification and direction of Engineer-in- charge (payment for providing grooves shall be made separately). |
| 26 | Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :15 mm wide and 15 mm deep groove |
| 27 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 28 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 29 | Supplying of Earth in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks for filling up ground depresssion lead upto 15 Km and lift upto 1.50 m. |
| 30 | Providing & Fixing backlit Signage of size 80 ft x 3ft made out of ACP of 3mm thickness with MS framework with 3D cut letters on the ACP. Having IP 68 rated samsung chip LED's of 10000K with 140lumens per feet for brightness & uniform illumination with no hotspots including material, labour charges, freight charges etc complete with 1 year warrenty on complete product and per direction of Engineer-In-Charge. |
| 31 | Supplying and installation testing and commossioning of 40 watts smart intergarated all in one solar light of Highty effeciency solar Panel LED light and long lite PO4 battery with high effieciency micriprocessor-based charge controller per motion sensor and compact in size complete etc as required make Bajaj /volmont/Phillips/lysaght). |
| 32 | Supplying and installation LED WALL LIGHT , energy saving, decorative IP 66 LED UP-down Luminaire with wall surface mounting using COB LED as light source as required make Bajaj /volmont/Phillips/lysaght/havells). |
| 33 | Providing, fixing erection and testing of 3\\" decorative street light of 6 Mtr. Hight having base plate welded on bottom of pipe of suitable thickness with foundation including excvation shuttering and cement concrete complete etc as required and as per direciton of the Engineer-in-charge at site. |
| 34 | Supply of 150 LED Luminaire for Flood Light with Warranty for free replacement 1 year 140 to 270 Volts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V, including all wiring, circuity, switch & installation (make for LED Street light Bajaj, Cropton, Orient or equivalent). |
| 35 | Providing and fixing play equipments (swings) at sites as per specifications ,Duplex MAPS D01 as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 36 | Providing and fixing play equipments (swings) at sites as per specifications combination set 3 in 1,as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 37 | Providing and fixing play equipments (swings) at sites as per specifications FRP Wave slide 2.1 mtr., as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 38 | Providing and fixing play equipments (swings) at sites as per specifications TODDLER Swing, as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 39 | Providing and fixing play equipments (swings) at sites as per specifications STANDARD SWING,,as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 40 | Providing and fixing play equipments (swings) at sites as per specifications CIRCULAR SWING,SIMPLY GO ROUND,as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 41 | Providing and fixing play equipments (swings) at sites as per specifications HALF ROUND NET,as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 42 | Providing and fixing play equipments (swings) at sites as per specifications Std. SEE-SAW (Double),as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 43 | Providing and fixing play equipments (swings) at sites as per specifications SPRING RIDER JUMBOas per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 44 | Providing and fixing automatic Barrier 6.00 mtr. lenght Hydraulic barrier or electro mechanicall Right/Left version likde BENINCA/FAAC/CAME/MAGNATIC Auto Control/Motion or equivlaent as approved by engineer-in-charge with boom opening/closing Time5-6 sec. Fully Automatic with use cycles 100% Duty with push button, Four J hooks, Foundation plaste oliv Round Boom Push Button with following specification power supply Vac/Hz 230+6% 10 50 Absorbed power w 220 absorbed current A 1 Type of oil accordingly as requiret Oil quanity L1 1.8 winding heat protection C 120 Anti crushing system standard by pass valves Type of slow down Electronic Operating ambient temperature C 20/+55, Hood protective treatment catachresis AISI316L Protection class IP-44 Body Dimensions 390mm, 200mm, 1080mm Electric motor detail tech 1400 rpm & to 2800rpm or as per direction of Engineer-in-charge |
| 45 | Providing Fixing and Installation of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make a Leg Curl & Extension Machine that contains a leg extension/curl dual action section that is affixed to the main monolitic curved arc tube central pillar without any convex sides of 89mm OD and min wall thickness of 3 mm & has a 8mm thick, 40cm gusset support using a ONE A.R.M MODULE ( Angular resistance, bearing less module ) that works as dual action [push and pull / extension & contraction]. The ARM must be bearing less, shock less, drop less and provide 0-30 kg resistance. The seats are fixed to the main curved central pillar and do not move up and down - [Are immovable] to ensure it is safe & stable, zero drops and support disable people to use the product without risk of falling or slipping off. All fasteners to be of 304 stainless, Torx Anti Vandal Fasteners, All nuts enclosed in Polyamide Anti Vandal Caps. The seat must consist of PU Polysafe cusions seats. Finishing to be Metalized / Plasma zinc injection + Dupont/Alexta outdoor use color powder electrostatic coating. All complete fixing of equipment in foundation is to done as per the direction of engineer in charge or as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 46 | Providing Fixing and Installation of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make Double Tai Chi Teflon Resistance Trainer. The unit must consist of 4 wave shaped fan blades made of high grade poly-ethylene, with rotate free grips & without any holes or gaps to prevent entrapment. The blades are attached to an ergonomically curved, monolithic large arc tube center pillar without convex sides & minimal deformation to provide a pleasing, mordern aesthetic look. The wall thickness of the main curved center pillar is minimum 3 mm & has a 8mm thick, 40cm gusset support. The blades are connected to high grade Teflon resistance maintainance free bearings. All fasteners to be of 304 stainless, Torx Anti Vandal Fasteners, All nuts enclosed in Polyamide Anti Vandal Caps. Finishing to be Metalized / Plasma zinc injection + Dupont/Alexta outdoor use color powder electrostatic coating. All complete fixing of equipment in foundation is to done as per the direction of engineer in charge or as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 47 | Providing Fixing and Installation of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make Double Shoulder Press Station that must contain of two A.R.M MODULES ( Angular resistance, bearingless module) that works as dual action [push and pull / extension & contraction] connected to a main center pillar of OD 89mm of min 3mm thickness. The A.R.M must be bearingless, shock less, drop less and provide 0-30 kg resistance. The seats are fixed to the main post and do not move up and down - [Seats are immovable] to ensure it is safe & stable, zero drops and support disabled people to use the product without risk of falling or slipping off. Finishing to be Metalized / Plasma zinc injection + Dupont/Alexta outdoor use color powder electrostatic coating. The handles are of 3mm Endu-Rubber with aluminum cap locking anti vandal system. All fasteners to be of 304 stainless, Torx Anti Vandal Fasteners, All nuts enclosed in Polyamide Anti Vandal Caps. All complete fixing of equipment in foundation is to done as per the direction of engineer in charge or as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 48 | Providing Fixing and Installation of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make a three person body twister station that consists of three swivel stands that rotates but with a built in safety limitor that meets international safety standards as the arms and shoulders of the user are held square in the overhead hold that is fixed to a monolithic large arc tube center pillar without convex sides & minimal deformation ergonomically curved. The Center pillar has an OD of 89 mm, the wall thickness is min 3 mm & has a 8mm thick, 40cm gusset support at standard height of 1.4m. All fasteners to be of 304 stainless, Torx Anti Vandal Fasteners, All nuts enclosed in Polyamide Anti Vandal Caps. Finishing to be Metalized / Plasma zinc injection + Dupont/Alexta outdoor use color powder electrostatic coating. All complete fixing of equipment in foundation is to done as per the direction of engineer in charge or as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 49 | Providing Fixing and Installation of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make a Foot Cycle that has a central pin which connects the 2 heavy flywheels & which has 2 main bearings and in addition has a TEFLON RESISTANCE BEARING which locks the pin and creates resistance to the spin. The central pillar is a monolithic large arc tube without convex sides & minimal deformation which is ergonomically curved with an OD of 89 mm, the wall thickness is min 3 mm & has a 8mm thick, 40cm gusset support at standard height of 1.4m. All fasteners to be of 304 stainless, Torx Anti Vandal Fasteners, All nuts enclosed in Polyamide Anti Vandal Caps. Finishing to be Metalized / Plasma zinc injection + Dupont/Alexta outdoor use color powder electrostatic coating. The seat must consist of PU Polysafe cushions seats. All complete fixing of equipment in foundation is to done as per the direction of engineer in charge or as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 50 | Providing Fixing and Installation of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make an ELIPTICAL cross trainer that consists of a central pin which connects the 2 heavy flywheels & which has 2 main bearings and in addition has a DUPLEX TEFLON RESISTANCE BEARING which locks the pin and creates resistance to the spin. The central pillar is a monolithic large arc tube without convex sides is & minimal deformation ergonomically curved with an OD of 89 mm, the wall thickness is min 3 mm & has a 8mm thick, 40cm gusset support at standard height of 1.4m. All fasteners to be of 304 stainless, Torx Anti Vandal Fasteners, All nuts enclosed in Polyamide Anti Vandal Caps. Finishing to be Metalized / Plasma zinc injection + Dupont/Alexta outdoor use color powder electrostatic coating. The handles are of 3mm rubber with aluminum cap locking anti vandal system. All complete fixing of equipment in foundation is to done as per the direction of engineer in charge or as per approved drawing & design given by manufacturer including earth work, c:c work up to plinth level in 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of required size as per department / manufacturers specifications and guidelines.Engineer In-Charge |
| 51 | Providing and fixing 36mm thick EPDM (Ethylene Propylene Deine Monomer) Rubber flooring on existing surface in required color and shape. The EPDM Rubber flooring should be laid at site in dual color and pattern as per the direction of the Engineer-in-charge. All complete fixing of equipment in foundation is to be done as per manufacturer specification.Engineer In-Charge Please Enable Macros to View BoQ information |