| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | M&L for dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed. |
| 3 | M&L for demolition of mud phuska on roof any thickness complete all as specified and directed. |
| 4 | M&L for roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. |
| 5 | M&L for PCC 1:3:6, type B-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100 ,complete all as specified and directed. |
| 6 | M&L dor dutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 7 | M&L for Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm th 5 layered APP membrane shall be laid using butane torch and sealling all joints etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength inlongitueinal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147)(iii) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only complete all as specified and directed. |
| 8 | M&L for Plain Cement Concrete tiles 25cm x 25cm x 22-25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished laid over 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 9 | M&L for Plain cement concrete 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregate as in roof kerbs or mud stops and benching, rounded or chamfered on edges, coving shall be 150 mm in radius mixed with acrylic based polymer water proofing compound complete all as specified and directed.Note:WPC shall be paid separately |
| 10 | M&L for taking down of Eaves gulter/rain water pipe(AC rain water pipe /SWG pipe line of any size or pattern), including at fittings, heads, shoes, bends, swan-necks, etc., including cleaning for refuxing or removal from site (measured overall as fixed along the centre line including fitting and accessories) complete all as specified and directed. |
| 11 | S&F uPVC (SWR) Type ‘B’ , 160 mm nominal outside diameter confirming to IS : 13592-1992 single socketed in any length including jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction, fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc complete all as specified and directed.Note : Clamps will be measured and paid separately. |
| 12 | S&F uPVC (SWR) bends, 160 mm dia confirming to IS : 14735-99 and jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction complete all as specified and directed. |
| 13 | S&F for MS Clamps, Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay) and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 14 | M&L for demolition of RCC work as in Roof slabs, floors slabs (other than ground floors), beams, roof beams, roof projections, chajjas, staircases, landing, chajjas, fins and similar suspended work including reinforcement cut as required to facilitate demolition including provision of necessary scaffolding for the same upto triple storey complete all as specified and directed. |
| 15 | M&L for Reinforced Cement Concrete (RCC) 1:2:4 using 20mm graded stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 16 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | M&L for Form work of flat surface rough finished to soffits of suspended slabs such as roof slabs, shelves not exc 200mm thick upto 10m height (Horizontal or sloping) complete all as specified and directed. |
| 18 | M&L for Form work rough finished to edges of concrete slabs exc 5 cm but not exc 10 cm thick complete all as specified and directed. |
| 19 | S&F MS hollow/solid angle section rectangular/ square/ circular tubes/ pipes of YST 310 Grade as in frame work for roofs/ rafters/ purlins/ chajjas/ trusses/ columns/ struts etc and like similar items etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
| 20 | S&F MS hollow/solid angle section rectangular/ square/ circular tubes/ pipes of YST 310 Grade as in frame work for roofs/ rafters/ purlins/ chajjas/ trusses/ columns/ struts etc and like similar items etc. complete all as specified and directed. Please Enable Macros to View BoQ information |