| 1 | Supply and filling compressor oil complete all as specified and directed. |
| 2 | Material and labour for charging of refrigerant gas R-410A/R-134A/R-22/R-32/R-407C in AC plant complete all as specified and directed. |
| 3 | Servicing of cassette type/ hi wall split type indoor units of cap 1.28/2.0/3.18/1.5/2.0 TR installed at high pulse bldg Zone-IV from OEM/ authorised dealer of OEM complete all as specified and directed. |
| 4 | Supply and fixing in replacement display controller complete unit of package type /central type AC plants of various capacity complete all as specified and directed. |
| 5 | Supply and fixing in replacement finned strip heater having terminal at one end and two holes at another end for installation, 240 volt, 2.5-3.0 KW complete all as specified and directed. |
| 6 | Supply and fixing in replacement finned strip heater having terminal at one end and two holes at another end for installation, 240 volt, 1.5-2.0 KW complete all as specified and directed. |
| 7 | Supply and fixing in replacement fan assembly with blade for FRP cooling towers as per sample of approved make complete all as specified and directed. |
| 8 | Supply, install, testing and commissioning of hermetically sealed scroll compressor of capacity 11.00 ton compatible with R22 refrigerant gas , suitable for water cooled AC plant complete all as specified and directed. |
| 9 | Supply, install, testing and commissioning of hermetically sealed scroll compressor of capacity 8.5 ton compatible with R22 refrigerant gas , suitable for duct able AC complete all as specified and directed. |
| 10 | Supply, install, testing and commissioning of hermetically sealed scroll compressor of capacity 5.5 Ton 3 phase 440 Volts compatible with R22 refrigerant gas , suitable for Duct able AC complete all as specified and directed. |
| 11 | Supply ,installation, testing and commissioning of centrifugal monoblock type pumping set i.e chiller water pump having discharge capacity minimum 500 LPM at 45 mtr head coupled with electric motor 3 phase, 415 volt ,50 Hz of suitable capacity (approx 10 HP or above) to drive pump delivering water up to 45 mtr head and suction del pipe size 100mmx100mm ,mounted on common MS base frame including PCC foundation, nut, bolts etc complete all as specified and directed. Modal no-KDS -1030+ , make -Kirloskar |
| 12 | Supply, replacing, commissioning and testing of mono block water pump set electric driven 415 volt 1450 RPM (approx. cap 7.5 HP or above) ,Kirloskar model no FEF42/XV-1004 suitable for existing suction/discharge 400 LPM and not less than 30mtr head suitable for condenser water complete all as specified and directed. |
| 13 | Supply and fixing in repairs MCCB rating 125 Amps, 4 pole, 415 volts breaking capacity 16 KA complete all as specified and directed. |
| 14 | Supply and fixing in repairs MCCB rating 250 Amps, 3 pole, 415 volts breaking capacity 36 KA complete all as specified and directed. |
| 15 | Supply and fixing in repairs MCB TPN rating 40-100 Amps, 4 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and directed. |
| 16 | Supply and fixing in repairs MCB TP rating 25-63 Amps, 3 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and directed. |
| 17 | Supply and fixing in repairs MCB SP rating 6-32 Amps, single pole, 240 volts complete all as specified and directed. |
| 18 | Supply and fixing in repairs MCB SPN rating 40-63 Amps, single pole neutral, 240 volts complete all as specified and directed. |
| 19 | Taking out old unserviceable power/auxiliary contactor from control panel / starter and supply and fix new power contactor of following size and capacity power contactors of AC3 rating 12 Amps MNX type complete all as specified and directed. |
| 20 | Supply and fixing for power contactors AC3 rating 22 Amps ML type complete all as specified and directed. |
| 21 | Supply and fixing for power contactors AC3 rating 32-40 Amps ML type complete all as specified and directed. |
| 22 | Supply and fixing in replacement phase failure relay with fixed under & over voltage cut out complete all as specified and directed. |
| 23 | Supply and fixing in replacement single phase preventor complete all as specified and directed. |
| 24 | Supply and fixing in replacement compressor motor protector relay 22A, 240V reset delay 30 min + 5 min complete all as specified and directed. |
| 25 | Supply and fixing in replacement time delay relay range 0-30 Sec complete all as specified and directed. |
| 26 | Supply and fixing in replacement of blower fan motor for 4.0 TR cassata type inverter AC as per existing pattern complete all as specified and directed. |
| 27 | Material and Labour for repair of printed control board (PCB) of indoor unit and outdoor unit both of cassette type AC (inverter type) Cap 4.0 TR as per existing pattern complete all as specified and directed. |
| 28 | Supply, installation and testing of printed control board (PCB) of indoor unit and outdoor unit both of cassette type AC (inverter type) cap 4.0 TR as per existing pattern complete all as specified and directed. |
| 29 | Supply, install, testing and commissioning of sealed unit compressor of cap 1.5 Ton after taking down defective compressor from foundation and making connection with suction/discharge of the AC capacity 1.5 Ton complete all as specified and directed. |
| 30 | Supply, programme , testing & commissioning of AC drive, 5.5kW ,V/F control, input 3- phase, 415Volt, AC, output 3phase, 415Volt, AC for control AHU motor of VRV/VRF AC plant and chiller plant complete all as specified and directed. MAKE- YASKAWA/Delta / ABB/Siemens |
| 31 | Supply, programme , testing & commissioning of AC drive, 2.2KW ,V/F control, input 3- phase, 415Volt, AC, output 3phase, 415Volt, AC for control AHU motor of VRV/VRF AC plant and chiller plant complete all as specified and directed. MAKE- YASKAWA/Delta / ABB/Siemens Please Enable Macros to View BoQ information |