| 1 | Repairs and maintenance of following electrical and mechanical installations(w.r.t electric related works ), details as follows and according to terms and conditions mentioned as per I.E. rules with specified attendance of wiremen and helpers/khallsis. a) E.i., Lights/Fans/Plug Points/Power Points and Street/Compound lightning arrangements as per I.E. Rules as detailed inside at page.b) Water Supply arrangementc) Water Coolers d) Air Coolers e) Air conditioner f) Feeder pillars/LT panels maintenance. |
| 2 | Note:(1) Contractor may read all the clauses including \\"GENERAL DESCRIPTION OF WORK FOR AMC OF ELECTRICAL AND MECHANICAL SERVICES\\" and ''Condition of contract'' of the MTF carefully before quoting rates. (2) Wages paid to the worker for this work must not less than minimum wage as provided by chief labour commissioner(C), ministry of labour & Employment(3) In addition to all the documents as described in MTF Clauses the Contractor has to submit Monthly Wagesheets & EPF/ ESIC Challans. (4)The contractor may be asked to produce Monthly Transaction receipt of monthly wage to be paid to the employed labour.(5) In case of non compliance of EPF act 1952/ partial submission of EPF Contribution, as specified in Condition of contract Clause 19B, FCI will be at liberty to withhold the pending bills, Security Deposit etc., and or any other payments due to the Contractor.(6) The contractor must arrange for all types of ladders (Self supported & wall supported), safety gears and tools at sites w.r.t. Working height up to 20 feets in suspension / wall or pole. |
| 3 | FSD Meghnagar (6960 MT Capacity) |
| 4 | Sub Head - 2 Materials as and when required only, for installation, no labour charges is to be involve, as the same has to be get replaced by staff supplied under AMC contract. |
| 5 | Supply of XLPE insulated PVC sheathed cable of 1.1 KV grade (heavy duty) armoured under ground aluminium conductor cable as required confirming to IS-1554(Part-1) with up to date amendments of the following sizes. : 2 x 10 sqmm |
| 6 | 4 x 16 sqmm |
| 7 | 4 x 25 sqmm |
| 8 | For Repairing of ceiling fan / exhaust fan: Capacitor |
| 9 | Bearing |
| 10 | Rewinding including credit the damage wire |
| 11 | Supply of FRLS PVC Insulated copper conductor single core cable of following sizes : 1.5 sqmm |
| 12 | 2.5 sqmm |
| 13 | 4 sqmm |
| 14 | Supply of following 6 amp to 32 amp capacity \\"c\\" curve MCB as and when required : Single pole MCB |
| 15 | Double pole MCB |
| 16 | Triple pole MCB |
| 17 | Supply of 25 amp capacity 30ma to 300ma breaking capacity RCCB |
| 18 | Supply of 63 amp capacity 30ma to 300ma breaking capacity RCCB |
| 19 | Providing for replacement of driver/ LED plate of following range of wattage capacity of well glass/ street light as required.: 30W to 70W |
| 20 | 71W to 150W |
| 21 | Supply of following sizes PVC conduit with saddle(Labour part involved vide AMC labour at Item 1) |
| 22 | PVC conduit-20 mm dia |
| 23 | Supplying of following sizes of steel conduit along with accessories in surface/recess including painting(Labour part involved vide AMC labour at Item 1) : 20mm |
| 24 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 25 | Providing 20 watt retrofit LED tube for replacement as required. (NABL certified as per specification) |
| 26 | Providing for replacement of Metalik box type batten fixture suitable for fixing of 18 to 22 watt LED tube rod with provision of conduit entry at side and top etc. as required. (NABL certified as per specification) |
| 27 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 28 | 50 Watt |
| 29 | 150 Watt |
| 30 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 31 | 30 Watt |
| 32 | 45 Watt |
| 33 | 70/72 Watt |
| 34 | Supplying / Installation / Testing / Commissioning of Pressure Die Cast Aluminum 35/ 36 watt LED well glasse having IK10 impact resistivity and 5KV inbuilt surge protection with high efficacy of greater than or equal to 140 lumens / watt fitting with control gear housing, IP 66 Protection with heat resistance glass eye bolt provided for mounting purpose & wire guard 35 / 36 Watt etc. as required of make of reputed brand under MII confirming to IS and IEC codes on the platform of godown truss/ truss of the shed blocks as directed by the Engineer incharge with M. S. clamps wiring with 3 x 1.5 Sq mm PVC insulated / WP flexible copper conductor wire, painting the clamps including connections and dismantling the existing fittings etc. as reqd. Ref. |
| 35 | 35/36 Watt |
| 36 | 70/72 Watt |
| 37 | Sub Head III - Repairs of Water Pump :Repairs and maintenance existing submersible tube well water pump including lifting from the existing bore well & re-installation/ refixing details are given as given below |
| 38 | Lifting & lowering the existing submersible water pump along with pipe line from bore well including G.I./PVC Pipe Line, Valves etc. as required. |
| 39 | Rewinding of submersible / monoblock / monosubmersible water pump including credit the damage wire. |
| 40 | Replacement of required accessories i.e. bearing, bush, etc. in submersible motor pump set. |
| 41 | Supply of following sizes PVC insulated and PVC sheathed multy strand copper conductor 1100 V grade submersible flat cable with provision of water tight joint as req.: 3 core x 2.5 sqmm |
| 42 | Sub Head IV - Credit to estimate |
| 43 | The items are to be dismantaled during the execution of work and items lying obsolete in the godown are to be take away by the giving the credit to the estimate as in where as basis. |
| 44 | Conduit Pipe, old Panel Board, MS clamp, Iron material etc |
| 45 | Iron and other metallic Scrap items Please Enable Macros to View BoQ information |