Tender For Repair Maintenance Of Various Electrical & Mechanical Services At D.C Office Old Gargi College Building Lajpat Nagar - Iv, New Delhi.(Sh:- Comprehensive Maintenance & Operation Of Panasonic Make Cctv System), Delhi-Delhi
TDR : 54792222
Tender Notice
BOQ
6 Days Left
Delhi
Delhi
Tender For repair maintenance Of Various Electrical & Mechanical Services At D.C Office Old Gargi College Building Lajpat Nagar - Iv, New Delhi.(Sh:- Comprehensive Maintenance & Operation Of Panasonic Make Cctv System)
Name of Work:- RMO Of Various Electrical & Mechanical Services at D.C Office Old Gargi College Building Lajpat Nagar - IV, New Delhi.(SH:- Comprehensive Maintenance & Operation of Panasonic make CCTV System)
Sl. No.
Item Description
1
Comprehesive Maintenance of camera i/c all components like cameras, SMS/VMS, NVR, Storage, Wiring, Server, software etc. as per inventory & Scope of work Comprehensive maintenance including all material and man power required to keep installation in working condition throughout the period complete etc. as reqd.(Panasonic Make)
2
OneYear
3
Operation & routine maintenance of CCTV system i/c monitoring and recording of events of various camera associated with the system on monthly basis, on all working days of the month except Sunday and gazetted holidays by deploying following staff complete as reqd. . (a) Technician - 1 No.(in general Shift)
4
One Year
5
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
6
1 Run of cable
7
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db/ km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required.
8
Single Mode 6 Core Optical fiber cable Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.