Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge |
| 2 | All kinds of soil @70% |
| 3 | Ordinary Rock @20% |
| 4 | Hard Rock (Blasting Prohibited) @10% |
| 5 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres. |
| 6 | All kinds of soil @70% |
| 7 | Ordinary Rock @20% |
| 8 | Hard Rock (Blasting Prohibited) @10% |
| 9 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : |
| 10 | All kinds of soil @70% |
| 11 | Ordinary Rock and hard @30% |
| 12 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed for lead up to 25 meter from cutting edge in All kinds of soil. |
| 13 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 14 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 15 | Providing and laying cement concrete in Protection walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size. |
| 16 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete. |
| 17 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 18 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 20 | Reinforcement for RCC works including straightening, cutting, bending, placing in position and binding all complete all work up to plinth level and above plinth level , Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 21 | Centering and shuttering including strutting, propping, etc and removal of form work for foundations , footings ,bases of columns etc. |
| 22 | Centering and shuttering including strutting, propping, etc and removal of form work for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 23 | Centering and shuttering including strutting, propping, etc. and removal of form work for columns ,pillars ,piers etc. |
| 24 | Centering and shuttering including strutting, propping, etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms. |
| 25 | Centering and shuttering including strutting, propping, etc and removal of form for Weather shades, chajjas, corbels etc. including edges |
| 26 | Centering and shuttering including strutting, propping, etc and removal of form for Stairs (excluding landings) except spiral staircases. |
| 27 | Centering and shuttering including strutting, propping, etc and removal of form work for lintels, beams , girders , bressumers and cantilevers all complete. |
| 28 | Centering and shuttering including strutting, propping, etc and removal of form for edges of slabs.(under 20 cm). |
| 29 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 30 | Brick work with common burnt clay (Non-Modular) bricks of class designation 7.5 in foundation and plinth including curing complete in Cement mortar 1:6 ( 1 cement : 6 coarse sand). |
| 31 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 32 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement: 3 coarse sand). |
| 33 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 34 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand), |
| 35 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1:6 ( 1 cement : 6 fine sand ) |
| 36 | 6mm cement plaster to ceiling of mix 1 : 3 (1 cement: 3 fine sand) |
| 37 | 15mm Cement plaster finished with a floating coat of neat cement of mix 1 : 3 ( 1 cement : 3 fine sand) |
| 38 | Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections |
| 39 | Making of Groove 12mmx10mm between brick and RCC |
| 40 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 41 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished including curing complete, (excluding floating coat of neat Cement). 50 mm thick with 20mm nominal size stone aggregate. |
| 42 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of tile 60x60cm. |
| 43 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.Size of tile 600x600 mm |
| 44 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.In all colours, shades, such as White, Ivory, Fume Red Brown. |
| 45 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 300x450mm as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 46 | Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete. |
| 47 | Extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. |
| 48 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 49 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 50 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood. |
| 51 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size). |
| 52 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws (35mm thick) |
| 53 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class deodar wood (35mm thick) |
| 54 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Particle Board 12mm thick and Pre-laminated particle board with decorative lamination on both sides, |
| 55 | Providing & fixing glazed shutters for doors , windows and clerestory windows using 10 Kg / Sqm. (4 mm thick) float glass panes , incl. ISI marked M.S pressed butt hinges bright finished off required size with necessary screws 35 mm thick of Second class deodar wood |
| 56 | Providing and fixing glass panes , with wooden fillets wherever : Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) |
| 57 | Providing and fixing wire gauze shutters 35 mm thick using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class deodar wood |
| 58 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc |
| 59 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : |
| 60 | 300 x 16 mm |
| 61 | 250 x 16 mm |
| 62 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 63 | 250x10 mm |
| 64 | 100x10 mm |
| 65 | Providing and fixing Aluminium hanging floor door stopper ISI marked anodized (anodic coating not less than grade AC 10 as per IS 1868 ) tranparent or dyed to required colour or shade with nuts and screws etc. complete twin rubber stopper. |
| 66 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 67 | 125mm |
| 68 | 100mm |
| 69 | Providing and fixing bright finished brass hard drawn hooks and eyes 150 mm |
| 70 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 71 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 72 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade |
| 73 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 74 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 75 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing |
| 77 | 15mm nominal outer dia pipes. |
| 78 | 20mm nominal outer dia pipes. |
| 79 | 25mm nominal outer dia pipes. |
| 80 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 81 | 15mm nominal outer dia pipes |
| 82 | 20mm nominal outer dia pipes |
| 83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc. |
| 84 | 20mm nominal outer dia pipes |
| 85 | 25mm nominal outer dia pipes |
| 86 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter.. |
| 87 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Coupler 110mm. |
| 88 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Single tee with door 110x110x110 mm. |
| 89 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Bend 87.5° 110 mm. |
| 90 | Providing & fixing PVC pipes 6 kg/ cm2 pressure excluding PVC fittings, jointing with adhesive/ seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion of approved make Supreme/ Finolex/ Astral or equivalent. |
| 91 | 110mm |
| 92 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalent. |
| 93 | 110mm dia Door Tee |
| 94 | 110mm dia Plain Bend |
| 95 | 110mm dia Collar. |
| 96 | 110mm dia P-Trap |
| 97 | 110mm Door Bend |
| 98 | 110mm dia Plain Tee |
| 99 | 110mm PVC Prince Cliff |
| 100 | 110mm x 80mm dia Reducer |
| 101 | 110mm 45 deg Bend |
| 102 | Providing and laying PVC accessories and fitting of approved make Supreme/ Finolex/ Astral or equivalent |
| 103 | 80mm 45 deg Bend |
| 104 | 80mm dia Door Bend |
| 105 | 80mm dia Door Tee |
| 106 | 80mm dia Plain Bend |
| 107 | 80mm dia Collar. |
| 108 | 80mm dia Floor Trap. |
| 109 | 80mm dia Plain Tee |
| 110 | 80mm PVC Prince Cliff |
| 111 | 80mm dia PVC Cowel Caps |
| 112 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 113 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 114 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 115 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 116 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 117 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 118 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 119 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 120 | Providing and fixing un-plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length. |
| 121 | Providing and fixing CP Neeple. |
| 122 | Providing and fixing C.P Cup. |
| 123 | Providing and fixing CP Grating. |
| 124 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. |
| 125 | Rectangular shape 453x357 mm |
| 126 | Providing and fixing soil, waste and vent pipes : 100 mm dia, Sand cast iron S and S pipe as per IS:1729 |
| 127 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 128 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms. |
| 129 | Providing and fixing PTMT Waste Pipe for wash basin and sink, of approved quality and colour: Flexible pipe 32 mm dia |
| 130 | Providing and fixing Ball Valve (brass) of approved quality,high or low pressure with plastic floats complete. 25 mm |
| 131 | Providing and fixing Ball Valve (brass) of approved quality,high or low pressure with plastic floats complete. 20 mm |
| 132 | Providing and fixing TANK NIPPLE |
| 133 | Providing and installation of electric water motor/pump having 01 H.P including all fitting complete. |
| 134 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 135 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 136 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 137 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 138 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 139 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 140 | Disposal of surplus earth for average lead of 1.0 Km. |
| 141 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. 40 mm thick with 20mm nominal size stone aggregate. complete (drain flooring) |
| 142 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 180 x 150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 143 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 144 | Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design: Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating |
| 145 | Constructing brick masonry manhole of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including Cover with frame complete as per standard design: |
| 146 | 1'X1\\" |
| 147 | 1.5'x1.5' |
| 148 | 2'X2' |
| 149 | REPAIR WORK Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 150 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : Of area of 3 sqm. and below |
| 151 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge: |
| 152 | 1:3:6 or richer mix (i/c equivalent design mix) |
| 153 | 1:4:8 or leaner mix (i/c equivalent design mix) |
| 154 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 155 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished including curing complete, (excluding floating coat of neat Cement). 50 mm thick with 20mm nominal size stone aggregate. |
| 156 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of tile 60x60cm. |
| 157 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.Size of tile 600x600 mm |
| 158 | Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level including curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse Sand) B 1st Sort |
| 159 | 15mm Cement plaster on the rough side of single or half brick wall of mix: ,1 : 4 ( 1 cement : 4 fine sand) |
| 160 | Pointing on stone work with cement mortar 1 : 3 (1 cement : 3 fine sand) , Flush/Ruled Pointing |
| 161 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead ,With cement mortar 1:4 (1 cement : 4 fine sand) |
| 162 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete. |
| 163 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick. |
| 164 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 165 | Varnishing with varnish of approved brand and manufacture:Two or more coats of glue sizing with copal varnish over and under coat of flatting varnish. |
| 166 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-ironframe or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 167 | Providing fixing PVC panelling for wall/Ceiling with heavy duty quality including all cost of fittings and fixtures complete. |
| 168 | Providing & fixing glazed shutters for doors , windows and clerestory windows using 10 Kg / Sqm. (4 mm thick) float glass panes , incl. ISI marked M.S pressed butt hinges bright finished off required size with necessary screws 35 mm thick of Second class deodar wood |
| 169 | Providing and fixing wire gauze shutters 35 mm thick using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class deodar wood |
| 170 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :250x16 mm |
| 171 | Providing and fixing Aluminium tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS 1868 ) tranparent or dyed to required colour or shade with nuts and screws etc. complete |
| 172 | 100x10mm |
| 173 | 200x10mm |
| 174 | Providing and fixing Aluminium hanging floor door stopper ISI marked anodized (anodic coating not less than grade AC 10 as per IS 1868 ) tranparent or dyed to required colour or shade with nuts and screws etc. complete twin rubber stopper |
| 175 | Providing and fixing Aluminium handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS 1868 ) tranparent or dyed to required colour or shade with nuts and screws etc. complete |
| 176 | 125mm |
| 177 | 100mm |
| 178 | Providing and fixing steel hooks for windows with necessary screws |
| 179 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 180 | Applying primming coat of approved brand and manufacture on wood work. |
| 181 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.two or more coats. |
| 182 | New Work |
| 183 | Old Work |
| 184 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 185 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 186 | Demolishing mud phaska in terracing and disposal of material within 50 meters lead |
| 187 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 188 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 189 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 190 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter.. |
| 191 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Coupler 110mm. |
| 192 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Single tee with door 110x110x110 mm. |
| 193 | Providing & fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expension (Make Supreme) Bend 87.5° 110 mm. |
| 194 | CARRIAGES Carriage of material by mechanical transportation. |
| 195 | Sand average lead 35 Km |
| 196 | Stone aggrigate 40mm and above Av. Lead 15.0 Km By M.T. |
| 197 | Stone agrigate below 40mm. average Lead 15.0 Km By mechenical means. |
| 198 | Bricks, average Lead 45 Km By mechenical means. |
| 199 | Stone Av. Lead 10.0 Km By M.T. |
| 200 | INTERNAL ELECTRIFICATION Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 201 | Group A |
| 202 | Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. |
| 203 | 20 MM |
| 204 | 25 MM |
| 205 | 40 MM |
| 206 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required. |
| 207 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 208 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 209 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 210 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 211 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 212 | Supplying and fixing modular blanking plate on the existing modular plate and switch box exculding modular plate as required |
| 213 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 214 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 215 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 216 | 6 way (4 + 18), Double door |
| 217 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. |
| 218 | Single Pole |
| 219 | Single pole and neutral |
| 220 | Supplying and fixing 40 A to 63 Arating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. |
| 221 | Single pole and neutral |
| 222 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.Bin the existing MCB DB complete with connections, testing andcommissioning etc. as required. |
| 223 | 40 A F.P MCB 10 Ka \\"C\\" Curve |
| 224 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 225 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 226 | 40 watt |
| 227 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 228 | 1200 MM |
| 229 | EXTERNAL ELECTRIFICATION Supply,installation with foundation as per approved Drawing 11 Mtr SP-56 M.S Pole |
| 230 | Supply,installation of Structural Steel as per Standard Approved Drawing |
| 231 | Supply,Installation and Commissioning of 11 KV Air Break Switch(200 Amps). |
| 232 | Supply,Installation of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 233 | Supply,Installation of 11 KV HG Fuse Unit . |
| 234 | Supply,Installation of Disc Insulator(B&S)70 KN suitable for 100 sq.mm Triple AAAC. |
| 235 | Supply and Installation of 100 Sq.mm AAAC Triple AAAC. |
| 236 | Supply,Installation of 11 KV Pin Insulator suitable for 100 sq.mm Triple AAAC. |
| 237 | Supply and Erection of 150 mm Dia. Heavy Class G.I Pipe for the Cable Protection |
| 238 | Supply and Installation of Anti Climbing Device |
| 239 | Supply,Installation and Commissioning of 11 KV Meter with suitable size Out door Type combined C.T and P.T's of 5/1A Accuracy Class 0.5 S Burden 100 VA 11 KV/Root3/110 V /Root3 |
| 240 | Supply, installation, testing and commissioning of following capacity(continuous loading) BEE 3 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural Air Natural] copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better),Dielectric material shall be type -A, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility forremote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS 1180 (Part-3) including first filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and duly ISI. Marked and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with +12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 40 dg.C for oil and 45 dg. C for winding up to 200 KVA and 45 dg.C for oil and 50 dg. C for winding for above 200 KVA. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by twocoats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible,as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. |
| 241 | 100 KVA |
| 242 | POWER AND CONTROL CABLES :- Supplying,Installation,Testing and Commissioning of Copper Earthing Electrode of Size 50 x 3000mm with Copper Pipe Outer Dia. 50 mm (+-) 5 %),Length 3000 mm,Inner & and Outer Strip Size 25X6mm (Copper),Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs. |
| 243 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 244 | Supplying,Installation,Testing and Commissioning of G.I Earthing Electrode of Size 50 x 3000mm with GI Pipe Outer Dia. 58 mm (+-) 5 %,Length 3000 mm,Inner & Outer GI Strip Size 32X6mm,Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs. |
| 245 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 246 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required. |
| 247 | Group A |
| 248 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 249 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. |
| 250 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 251 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 252 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 253 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 254 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 255 | 1 x 1.5 sq. mm |
| 256 | supplu and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 257 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 258 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providng andfixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required. |
| 259 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 260 | Supplying & fixing suitable size GI box wih modular plate andcover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\"curve including connections, painting etc. as required.(For Geyser) |
| 261 | Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. |
| 262 | 25 mm |
| 263 | 40 mm |
| 264 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 265 | 8 way (4 + 24), Double door |
| 266 | 6way (4 + 18), Double door |
| 267 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. |
| 268 | Single Pole |
| 269 | Single pole and neutral |
| 270 | Supplying and fixing 40 A to 63 Arating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. |
| 271 | Single pole and neutral |
| 272 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.Bin the existing MCB DB complete with connections, testing andcommissioning etc. as required. |
| 273 | 40 A F.P MCB 10 Ka \\"C\\" Curve |
| 274 | 32A F.P MCB 10 Ka \\"C\\" Curve |
| 275 | 63 A F.P MCB 10 Ka \\"C\\" Curve |
| 276 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. |
| 277 | 12 way , Double door |
| 278 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 279 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim |
| 280 | 12 -15 watt |
| 281 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 282 | 120 watt |
| 283 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 284 | 1200 MM |
| 285 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 286 | 40 watt |
| 287 | Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of Metal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required . |
| 288 | 300 mm |
| 289 | Supply installation testing and commissioning of IP:20 Decorative Light 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 290 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 291 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 292 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 293 | Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55)( Transformer Distribution Panel Board- Kindergarten & Hall) ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD . |
| 294 | INCOMER Adj. TMR Based MCCB 125 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH |
| 295 | 200 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 296 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 297 | OUTGOINGS Manual Changeover 125 A F.P 415 Volts with AC-23 Duty |
| 298 | Adj. TMR Based MCCB 100 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH |
| 299 | Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH |
| 300 | D.P 40 A 10 Ka \\"C\\" Curve MCB |
| 301 | Load Bearing Members to be made out of 2.0 mm CRCA Sheet.Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick. Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board- Kindergarten & Hall) ) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD . |
| 302 | INCOMER Adj. TMR Based MCCB 100 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH |
| 303 | 150 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 304 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 305 | OUTGOINGS F.P 40 A 10 Ka \\"C\\" Curve MCB |
| 306 | F.P 63 A 10 Ka \\"C\\" Curve MCB |
| 307 | Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick. Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)( Building Distribution Panel Board- 2+2 Classrooms) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLD . |
| 308 | INCOMER Adj. TMR Based MCCB 63 Amps FP Icu=Ics=100% Breaking Capacity 36 KA with Extendable ROH |
| 309 | 100 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 310 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 311 | OUTGOINGS F.P 32 A 10 Ka \\"C\\" Curve MCB |
| 312 | Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick. Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 313 | 120 mm dia (OD-120 mm & ID-103mm nominal) |
| 314 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 315 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 316 | 3.5 C X 50 Sq.mm A2XFY |
| 317 | 3.0 C X 10 Sq.mm A2XFY |
| 318 | 3.5 C X 25 Sq.mm A2XFY |
| 319 | 3.5 C X 35 Sq.mm A2XFY |
| 320 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) |
| 321 | 3½ X 50 sq. mm (35mm) |
| 322 | 3.0 C X 10 sq. mm (22mm) |
| 323 | 3½ X 35 sq. mm (32mm) |
| 324 | 3½ X 25 sq. mm (28mm) |
| 325 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 326 | 1 or 2 Module (75mmX75mm) |
| 327 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 328 | Computer Socket RJ45 Modular type |
| 329 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 330 | 1 run of cable |
| 331 | Supply & Erection of lockable 12 U rack with 5A strip and two fan for distribution, mounting of patch panels, hubs, switches etc,, complete as per specification and as desired by EIC. |
| 332 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 333 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 334 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 335 | Supplying,Testing and Commissioning of 12 V 1.5 KVA Sine Wave Inverter with 1 Nos of Tall tubular inverter battery 150 Ah. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail