| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes pierholes etc n.exc 1.5m in depth and getting out in soft/loose soil etc complete all as specified and directed. |
| 2 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete etc complete all as specified and directed. |
| 3 | M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 5 | Removing excavated soil to a distance n.exc 50 m and depositing complete all as specified and directed. |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) etc complete all as specifed. |
| 7 | M&L for 25mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in floor finished rough to receive tiles complete all as specified and as directed. |
| 8 | M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) light shade polished, area of each tiles exc. 0.42 sqm but n.exc 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed. |
| 9 | All as per item No. 8 above but in vertical surfaces such as skirting & dado, laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 10 | M&L for RCC- M -30 Design Mix as in beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed. |
| 11 | Use and waste of formwork to sides and sofit of Beams for Fair finished surfaces. |
| 12 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 13 | All as per Item No 12 above but 5mm dia and over up to and including 10mm dia as in stirrups, spacers, binders complete all as specified and directed. |
| 14 | S&F Steel works In tubular posts/ trusses/ purlin including special shaped washer etc.complete using ERW or induction butt welded tubes conforming to IS 1161-1797 grade St 240 complete all as specified and directed. |
| 15 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc and fixed by riveting or welding or with nut and bolts (including nuts and bolts) conforming to Fe-410-W grade E 251 Quality B complete all as specified |
| 16 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified |
| 17 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified |
| 18 | S&F 0.56mm Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) etc complete all as specified and as directed. |
| 19 | M&L Painting to new steel and iron surfaces of exc. 10cm wide or girth by two coats of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified |
| 20 | M&L for preparation of old painted steel surfaces over 10 cm in width or girth and applying one coat of synthetic enamel paint etc complete all as specified and directed. |
| 21 | M&L Rendering 10mm thick on concrete surfaces in CM (1:6) finished even & smooth without using extra cement complete all as specified and directed. |
| 22 | M&L 15mm thick rendering in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces finished even and smooth without using extra cement. (Note : Water proofing compound shall be measured and paid seperately) complete all as specified and directed. |
| 23 | Supply only integral WPC (3% by wt of cement). |
| 24 | M&L for applying 1mm thick wall care putty on newly plastered surfaces of wall etc complete all as specified and directed. |
| 25 | M&L for preparing newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer etc complete all as specified and as directed. |
| 26 | M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper etc complete all as specificed and as per directed. |
| 27 | M&L for preparation of newly plastered surfaces of wall and applying two coat of weather proof exterior acrylic emulsion paint with anti fungal property over a coat of primer complete all as specified and directed. |
| 28 | M&L for preparation of old surfaces of wall and applying two coat of weather proof exterior acrylic emulsion paint with anti fungal property etc complete all as specified and directed. |
| 29 | S&F powder coated (min thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators and partitions (fixed portions) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed |
| 30 | S&F powder coated (min thickness of powder coating 50 micron) aluminium for shutters of openable/sliding doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 31 | S&F Aluminium anodised barrel tower bolt of extruded section of size 150mm long complete all as specified. |
| 32 | S&F cold rolled mild steel butt hinges 100 mm long medium weight complete all as specified and directed. |
| 33 | S&F 150mm long extruded aluminium alloy handle, fabricated type, anodised etc complete all as specified and as directed. |
| 34 | S&F aluminium alloy, anodised, sliding door bolt with hasp, staple & fixed clips of sheet, cast or extruded section & fixed bolts & sliding bolts of extruded section or cast aluminium alloy, length of bolt 300 mm etc complete all as directed. |
| 35 | S&F Aluminium (extruded section) Door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed etc complete all as directed |
| 36 | S&F 4.00 mm thick sheet glass ordinary quality n.exc 0.5 sqm etc complete all as directed. |
| 37 | Supply and fix aluminium composite panel sheet of 4 mm thick with 0.5 mm thick aluminium sheet both sides as in cupboards,wall cladding and false ceiling fixed on aluminium frame works with plastic strips (Double sided sticker ) of suitable size of varying thickness of 10mm to 30mm applying adhesive complete all as specified and as directed. |
| 38 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre with and including hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long etc complete all as specified |
| 39 | S&F 10mm PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing etc complete all as specified and as directed. |
| 40 | Taking down carefully aluminium point wiring (light, fan, socket or power) DBs complete offering credit, making good disturbed surfaces of walls, floors, etc, all as specified and as directed. |
| 41 | M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, etc., all as specified and as directed for one light point controlled by one one way switch. |
| 42 | All as per item No. 41 above but for one fan point complete all as specified and as directed |
| 43 | All as per item No. 41 above but for 5 Amps switch socket point on the same board complete all as specified and as directed |
| 44 | All as per item No. 41 above but for 3 pin switch socket outlet point 5 amps on independent board complete all as specified and as directed. |
| 45 | Supply and fix switch piano flush button single pole oneway 5 amp complete all as specified and as directed. |
| 46 | Supply and fix switch socket combination 3 & 2 pin (multi pin) 5 amp flush type complete all as specified and as directed. |
| 47 | All as per item No 41 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed. |
| 48 | Supply and fix switch socket outlet multipurpose 3 pin 15 and 5 amp controlled by one switch, flush type complete all as specified and as directed. |
| 49 | Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed. |
| 50 | Supply and fix fan speed regulator, electronic suitable socket type for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge |
| 51 | Supply and fixing in replacement energy efficient aluminium housing LED Smart bright batten 20 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected. |
| 52 | S & F in replacement of 36 W ceiling recessed light of size (2x2 ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. |
| 53 | S&F in replacement 36 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed. |
| 54 | Taking down old serviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers & bolts including cotter pin for complete all as directed. |
| 55 | Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs,complete all as specified and directed. |
| 56 | Supply and fix in repair MCB single pole 240 volts, 6 to 32 amps \\"C\\" series complete all as specified and as directed |
| 57 | Supply and fix in repair single pole and netural 240 Volts 6 To 32 amps complete all as specified and as directed |
| 58 | M & L in repairs for sub main wiring complete with three runs of 4 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 4 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Three runs of wire one run of conduit & one run of earth continuity conductor shall be measured as one running metre. |
| 59 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work including taking out old earthing complete all as specified and directed electrical plate No. 3 of SSR part - I |
| 60 | Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 3 Core 16 sq mm including taking down old cable complete all as specified and as directed . |
| 61 | Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed. |
| 62 | S&F 50 mm GI tubing light grade galvanised with all fittings laid in trenches complete all as specified and as directed . |
| 63 | Material and Labour for cutting existing BT / PCCroad of size 45cm x 60cm for taking out/laying of underground cable/pipe and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and as directed . Please Enable Macros to View BoQ information |