| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 7 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 9 | 3 pin 5/6 A socket outlet |
| 10 | Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 12 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 13 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 16 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 17 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 18 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (for A.C. Point/MCB Point) |
| 19 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door |
| 20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 21 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 22 | Supply and fixing of 40 Amp. FP MCB (10 KA) C Curve. CAT A |
| 23 | Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A |
| 24 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 25 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 26 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 27 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 28 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 29 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 30 | Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypeIncoming -200 Amp MCCB-1 No.Bus-Bar -200 Amp /415 Volt MCCB -1 No.Outgoing -63 Amp 4P MCCB - 2 Nos. (for power d.b.),40 Amp 4P MCCB - 4 Nos. (for light d.b.),63 Amp 4P MCCB - 1 Nos. (Spare),40 Amp 4P MCCB - 1 Nos. (Spare) |
| 31 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA |
| 32 | Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA |
| 33 | Supply of Recess mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect. |
| 34 | Supply and fixing of 3 watt to 6 watt LED (spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light) |
| 35 | SITC of LED Spike & Spot Light 8W warm white color made up of Aluminum. Optics: Carclo/Kathod, Beam Angle shall be 8 Degrees. Fixture shall be IP66 Protected with Meanwell Driver or Equivalent. Philips/Siems/or Equivalent) |
| 36 | Supply and fixing of Track mounted accent lighting fixture in pressure diecast housing, ST27IT Led20/8300 PsU-E WB(make: Philips/Siems/or Equivalent) |
| 37 | SUPPLY & FIXING UNIIn-Ground Linelight BBP403 LED50/WW 9W 24V L 1200 (Philips/Siems/or Equivalent) |
| 38 | Supply and fixing of 47 CW Flood Light: Floodlight With Knuckle IP65, Cool White 1000lm 110-120V (Philips/Knuckle//Siems/or Equivalent) |
| 39 | SITC LED Wall Washer 20 Watt IP66 having system efficacy of 100 LPW with pressure die cast aluminium housing with 3000 K CCT. Wipro Cat.Code : LF01-181-XXX-30-G1 or Equivalent in Philips , LT, Regent. |
| 40 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 95 sq mm x 3-1/2core |
| 41 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. |
| 42 | Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. |
| 43 | Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. |
| 44 | Supply, Installation & testing of Outdoor/Indoor 1080p HD indoor IP dome camera with 1/2.8\\" CMOS sensor pixel 1920 x 1080, IR on at 30IRE, 1/30s, 30fps, IR - 30 mtr, dynamic range 90db, true day/night, automatic electronic shutter, video compression H.264, motion/tamper, privacy mask, motion detection, auto varifocal lens 3 to 9 mm lens, audio - 1/1 channel in/out, full duplex audio, audio compression AAC, G.711, memory card slot (support up to 64GB), ONVIF profile S, CE, UL, FCC certified. |
| 45 | Supply, Installation, Testing & Commissioning of 8 Channel Digital Video Recorder with specifications as follow: Supported Image Format h.264 , H.265, MPEG-4, JPEG, M-JPEG; Supported Image Resolution 1920x1080, 1,280 x 960, 960 x 720, 640 x 480, 320 x 240; Maximum Number of Cameras 8 ; RAID 5, 320MBps incoming bandwidth Camera Control Pan/Tilt, Zoom, Focus, Brightness, Preset position call and program (up to 256), Auto mode GUI REC/Playback Control REC, PLAY, Rev PLAY, Pause; Network Interface Camera port: 10Base-T / 100Base-TX Min 4x 6TB can be installed. Certification: UL, CE, BIS, FCC. |
| 46 | 6U rack with all accessories |
| 47 | Supply and laying of 3 core 1.5 sqmm copper cable unarmoured |
| 48 | Supply and laying of CAT 6 UTP cable |
| 49 | Supply and laying of 25mm dia PVC conduit. |
| 50 | Supply, installation and commissioning of workstation latest intel i7 7th generation processor, intel chipset motherboard, 8 GB DDR3 RAM, 2 TB SATA HDD at 7200 rpm, graphics card 2GB dedicated RAM with dual display ports DVI/HDMI port, DVD writer, Giga LAN card, keyboard, optical mouse as per list approved makes TFT monitors 21inch or bigger. |
| 51 | SITC of 40\\" flat screen HD professional LED suitable for 24x7 operation with remote control and wall mount unit / floor stand complete with making connection etc as per list of approved makes. |
| 52 | Supply, installation and testing of UPS 1 KVA capacity. |
| 53 | Supply, Installation, Testingand Commissioning of on grid Solar Photo voltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/ Poly Crystal line silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/ GI structure of suitable strength with following components complete as required:-a)Solar Photo voltaic Module of capacity 330 W porabove , manufactured in India, conforming to IS14286/ IEC61215 ,IS/IEC61730 - Part-1,IS/IEC61730 - Part-2. Solar Photo voltaic Module conversion efficiency shall not be less than 16.5% .PV modules used in solar power plants/ systems must be warranted for the in output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% attheend of 25 years.b) Power Conditioning Unit (PCU) of 350-800 VDC Input voltage range and 400 VAC, three phase, 4wire, 50Hz+/- 5 Hz, output voltage suitable to generate ACP ower with efficiency not less than 97%, to talharmonic distortion less than 3% and suitable for ambient temperature from 0 to50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d)FixingofArrayjunctionbox&MainjunctionboxwithIP65protectionandterminationarrangementforincomingandoutgoingcablealongwithglands,lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f)Connections&Interconnectionsbysupplying&fixingrequiredsizeXLPEinsulatedcopperconductor1.1kVgradearmouredpowerandcontrolcablesbetweensolarmodules,mainpowercabletogridsupplyPCUunitalongwithsupplying&fixingofnecessarychannel/ |
| 54 | S/F of 1.5 Ton Split AIR CONDITIONER SYSTEM |
| 55 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 56 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 57 | Less 5% of DAO Please Enable Macros to View BoQ information |