| 1 | Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Extra for earthwork in Hard soil as per specification and direction of E/I. |
| 3 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 4 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 Coarce sand (zone-III): 6 Grade stone aggregate 40 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size) |
| 7 | Reinforcement cement concrete work in walls (any thickness), including attached pilasters, buttersses, plinth and string cource, filleets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size): At Column upto Ground Floor |
| 8 | Providing designation 75A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth curing, taxes and royalty all complete as per building specication and direction of E/I. |
| 9 | Providing and laying damp proof course 50 mm thick with cement concrete 1:2:4 (1 Cement : 2 Coarce sand (zone-III) : 4 Graded stone aggregate 20 mm nominal size) |
| 10 | Providing designation 75 B brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 11 | Reinforcement cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarce sand (zone-III) : 3 Graded stone aggregate 20 mm nominal size): At Lintel Band |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 17 | Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window) gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size, applying a prim ing red lead paint over steel work,taxes all complete as per specification and direction E/I. |
| 18 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specification and direction of E/I. |
| 19 | Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19mm thick (1:2:4) with 12 mm to 6mm size graded stone chips and top layer 6 mm thick (1:2:4) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/I |
| 20 | Providing 12 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 21 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab beam at the time of casting all complete as per building specification and direction of E/I. |
| 22 | Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) |
| 23 | Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 24 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 25 | Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M 1.5 with floating coat of neat cement in skirting including rounding of junctions with flor, curing, taxes and royalty all complete as per building specification and direction of E/I |
| 26 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 27 | Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I. |
| 28 | Supplying, fitting & fixing C.A.R.W.D. pipe with necessary strips, spikes, bends, shoes etc. including cost of carriage all complete as per building specification and direction of E/I. |
| 29 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 |
| 30 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 |
| 31 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 |
| 32 | Making plinth protection 50mm thick of cement concrete (1:3:6) over 75 mm thick bed of dry brick ballast 40 mm nominal size of well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 33 | Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l. |
| 34 | Supplying all materials, Labours, tools & doing 75 B, one brick flat soiling (70 mm) in foundation trenches joints filled with local sand as per specification & direction of E/I. |
| 35 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering M75 complete. 1:4:8 (1 Cement: 4 coarse sand(zone-III) : 8 graded stone aggregate 20 mm nominal size). |
| 36 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 37 | Providing designation 75B Brick work in C.M.(1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints cost of screening carriage of materials, raking out joints to 15mm. depth , curing , taxes and royalty all complete as per building specification and direction of E/I. |
| 38 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 39 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing and 1.5mm cement punning including curing, carriage of water with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 40 | Providing 50mm dia good quality G.I Pipe ------------------------- E/I. |
| 41 | Providing two coats of synthetic enamel paint of approved shade and make over red lead paint over steel surface including cleaning the surface thououghly, scaffolding and taxes all complete as per building specifications and direction of E/I |
| 42 | Wiring for fan point / light point / exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated copper conductor in recessed conduit. |
| 43 | Wiring for light/ power plug with 2x4 sq. mm. FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 no. 4 sq. mm FR PVC ……………….. as required. |
| 44 | Wiring for circuit/ sub main wiring along with earth wire with following sizes PVC insulated copper conductor single core cable in surface/ recessed PVC couduit …………... as required. 2 x 1.5 Sq mm + 1 x 1.5 sq mm earth wire |
| 45 | Wiring for circuit/ sub main wiring along with earth wire with following sizes PVC insulated copper conductor single core cable in surface/ recessed PVC couduit …………... as required. 2 x 2.5 sq mm + 1 x 1.5 sq mm earth wire |
| 46 | Wiring for circuit/ sub main wiring along with earth wire with following sizes PVC insulated copper conductor single core cable in surface/ recessed PVC couduit …………... as required. 2 x 4.0 sq mm + 1 x 4.0 sq mm earth wire |
| 47 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm dia |
| 48 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia |
| 49 | Supplying and fixing following way, single pole and neutral, sheet, MCB distrubution board,240 volts on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar …………………. as required. (But without MCB/RCCB/Isolator)12 way single door |
| 50 | S/F of following , following 240 volts, 'C' series, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete …………... as reqd.6/32 amps, Single pole |
| 51 | S/F following rating,double pole 240 volts, isolator in the existing MCB DB complete ………………. as reqd.63 amps |
| 52 | Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box/wooden block ……………. as reqd. |
| 53 | Supplying and fixing batten/ angle holder including connection ……………. as reqd. |
| 54 | ITC of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm. FR PVC insulated copper conductor ………………… as reqd. |
| 55 | Supplying 48\\" dia. Sweep celling fan with eloctronic regulator of any ISI make including connection with 1.5sq.mm. Copper wire drawn of the roof including taxes, carriage to worksite etc. all complete job. |
| 56 | Supplying & fixing of holder type LED 15W bulb of any ISI make including taxes, carriage to worksite etc. complete job. |
| 57 | Suppolying and fixing metal box of the following sizes in recesses with suitable size of pohonic laminated sheet cover front including painting etc. as required. 210 mm x 206 mm x 48 mm(10\\"X12\\") |
| 58 | Suppolying and fixing metal box of the following sizes in recesses with suitable size of pohonic laminated sheet cover front including painting etc. as required. 170 mm x 221 mm x 48 mm(8\\"X10\\") |
| 59 | Suppolying and fixing metal box of the following sizes in recesses with suitable size of pohonic laminated sheet cover front including painting etc. as required. 75 mm x 75 mm x 50 mm (4\\"X4\\") |
| 60 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 A switch |
| 61 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet |
| 62 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A amp switch |
| 63 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A socket outlet |
| 64 | Carriage of materials to worksite by any mechanical means including loading at querrysite / godown and unloading at worksite including all taxes, cost of labour, fuel, lubricants etc. all complete as as per building specification and direction of E/I.I. ) Bricks Lead (45) KM. |
| 65 | II) Sand Lead (25) KM. |
| 66 | III.) Stone Chips Lead (80)KM. |
| 67 | IV.) Stone Metal Lead (80)KM. |
| 68 | V.) Cement & Steel Lead (15) KM. |
| 69 | Add 18 % GST |
| 70 | Add 1% LC Please Enable Macros to View BoQ information |