| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 2 | CC 1:5:10 with stone ballast 40mm gauge |
| 3 | First class BB work laid in CM 1: 5 in foundation & plinth |
| 4 | Centering & shuttering for concrete foundations, foundation beams, plinth beams etc. |
| 5 | Centering & shuttering for sides & soffits of beams, lintels etc. |
| 6 | Centering & shuttering for flat surfaces such as landings chajjas shelves etc. |
| 7 | Reinforced cement concrete M-20 using concrete mixer but excluding steel reinforcement centring and shuttering in foundation & plinth |
| 8 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 9 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 10 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 11 | Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. |
| 12 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure |
| 13 | 20 mm thick cement plaster 1:4 in two coat work |
| 14 | 12.5mm thick cement plaster in CM 1:5 |
| 15 | Earth filling under floor got from excavation |
| 16 | Earth filling under floor brought from outside within a lead of 2 to 5 kms |
| 17 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 18 | Plastering on underside of ceiling 10mmthick cement plaster 1:4 |
| 19 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) |
| 20 | Grouting the joints of flooring tiles having 3mm width using 2mm to 3mm gap using spacer and later this gap to be filled with epoxy grout |
| 21 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 22 | Fixing vitrified floor tiles with cement based high polymer modifed quick set tile adhesive (water based) conforming to IS 15477 in average 3mm thickness |
| 23 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : |
| 24 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever requiredincluding the cost of PVC Plug / neoprene gasket required |
| 25 | Cost of Aluminium fittings ISI marked complete for doors, windows, such as tower bolts, handles and screws etc. for these fittings (excluding sliding bolts). For Shutter area above 0.50 Sqm |
| 26 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) |
| 27 | Wire guage fixed on steel windows of standard rooled steel section with 3mm thick flat iron cover moulding |
| 28 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side. |
| 29 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 30 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where speciallyspecified. |
| 31 | Terracing consiting of machine made Hollow Clay Tiles 80mm thick (Smooth surface) confirming to IS: 3951 (Part-I)-2009 laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm on top of R.C.C. slab including grouting with cement sand mortar 1:4 having 10mm wide joints spacing on all sides of tiles and top surface to be left clean complete as per specification (laying shall be done as perPWD specifications). |
| 32 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete |
| 33 | Bottom Khurra on ground 1.2m x 0.6m Mtr. Consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick |
| 34 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf/cm2) conforming to IS : 4985, including fixing with MS clamps |
| 35 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 36 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 37 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 38 | Finishing walls with extrior Acryluic smooth exterior paint of required shade with two coats applied @ 1.67 litre / 10 Sqm over and including base of water proofing cement paint @ 2.20 Kg/10 Sqm |
| 39 | Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and to the entire satisfaction of engineer-in- charge. |
| 40 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Slab sizes from 0.30 sqm to 0.50 sqm. |
| 41 | Precast chequred tiles of 20mm minimum thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base for floors, treads of steps and landing |
| 42 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 43 | Applying priming coat with metal primer including painting two coats with ready mixed paint on metallic surface |
| 44 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) |
| 45 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. |
| 46 | Providing & Fixing 6mm Thick Bison Board waterproof paneling on wall with help of PVC Gatti & SS Screwupto 3'-6\\" high on periphery wall of inside hall complete |
| 47 | Providing and fixing of Back Panel of Reception comprising of framing of 50mm x 50mm Partal/ Sal wood or equivalent with 3mm thick backing of Bakelite sheet on wall side,6mm thick waterproof ply on both sides and front portion fixed with 1mm thick laminate of colour and shade to be approved by Architect.Grooves in laminate or else where to be provided as per architectural drawing. The make of ply and laminate and colour of laminate shall be provided as per approval by Architect/ Engineer-in-charge |
| 48 | Construction of Plinth Protection |
| 49 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 50 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type |
| 51 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 52 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 53 | Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 54 | 12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. |
| 55 | Provision for Interlocking Paver Blocks |
| 56 | Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density |
| 57 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. |
| 58 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge |
| 59 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear fromthe edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 60 | CC 1:5:10 with stone ballast 40mm gauge |
| 61 | Centering & shuttering for sides & soffits of beams, lintels etc. |
| 62 | Centering & shuttering for flat surfaces such as landings chajjas shelves etc. |
| 63 | Damp proof course 4cm thick of cement concrete 1:2:4 with water roofing compound as per manufactures guidelines. |
| 64 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 65 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 66 | First class BB work laid in CM 1: 5 in foundation & plinth |
| 67 | First class BB work laid in CM 1:5 in super structure |
| 68 | 20 mm thick cement plaster 1:4 in two coat work |
| 69 | 12.5mm thick cement plaster in CM 1:5 |
| 70 | Earth filling under floor got from excavation |
| 71 | Earth filling under floor brought from outside within a lead of 2 to 5 kms |
| 72 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 73 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable andmake na ideal choice for high traffic zones.) |
| 74 | Grouting the joints of flooring tiles having 3mm width using 2mm to 3mm gap using spacer and later this gap to be filled with epoxy grout |
| 75 | Fixing vitrified floor tiles with cement based high polymer modifed quick set tile adhesive (water based) conforming to IS 15477 in average 3mm thickness |
| 76 | Providing and fixing aluminium partitioning - Fixed Portion |
| 77 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever requiredincluding the cost of PVC Plug / neoprene gasket required |
| 78 | Cost of Aluminium fittings ISI marked complete for doors, windows, such as tower bolts, handles and screws etc. for these fittings (excluding sliding bolts). For Shutter area above 0.50 Sqm |
| 79 | Providing & fixing glazing in aluminum door and windows - Float glass 5.5 mm thick |
| 80 | Wire guage fixed on steel windows of standard rooled steel section with 3mm thick flat iron cover moulding |
| 81 | Providing & Fixing prelaminated particle board laminated both sides |
| 82 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 83 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 84 | Terracing consisting of tiles 22.86x11.43x3.83 cm laid over 25mm mud plaster and two coats of bitumen complete as per specification |
| 85 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete |
| 86 | Bottom Khurra on ground 1.2m x 0.6m Mtr. Consisting of brick on edge laid in cement mortar 1:3 over 75mm cementconcrete 1:8:16 including 12.5mm thick |
| 87 | Preparation of plastered or concerete surface with cement based putty |
| 88 | Distempering with washable OBD two coats over one priming coat to give an even shade |
| 89 | Finishing walls with extrior Acryluic smooth exterior paint of required shade with two coats applied @ 1.67 litre / 10 Sqm over and including base of water proofing cement paint @ 2.20 Kg/10 Sqm |
| 90 | Wrought iron and mild steel ladders , framed grill , grating etc |
| 91 | Applying priming coat with metal primer including painting two coats with ready mixed paint on metallic surface |
| 92 | PUBLIC HEALTH WORKS |
| 93 | Base course of floor consisting of 100 mm thick cement concrete 1:8:16 with stone aggreate 40mm guage and 100 mm fine sand filling.(using mechanical mixer for mixing of material) |
| 94 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 95 | Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer |
| 96 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 97 | Providing & Fixing in position 15 mm i/d Pillar cock foam flow of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 98 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respect - C.P. brass towel Rails size 15 mm dia 600 mm long |
| 99 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 100 | Providing & Fixing in position 5 mm thick bevelled edge mirror of superior glass (of approved make) complete with 4 mm thick hard board backing fixed in with rawl plugs 50 mm , C.P. brass screws and washers complete in all respect (as required by the Engineer-in- Charge) |
| 101 | Size 600 mm x 450 mm. |
| 102 | Providing & Fixing in position 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 103 | C.P brass Bib cock long nose/ long body without flange |
| 104 | C.P. brass Bib cock foam flow without flange |
| 105 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 106 | C.P. Brass 15 mm Angle valve without flange |
| 107 | Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 3 Star Make:- Carrier, O-General, Daikin, Toshiba with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 108 | Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 3 Star Make:- Carrier, O-General, Daikin, Toshiba with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 109 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 110 | Automatic Voltage Stablizer 2 KVA |
| 111 | Providing laying hard soft copper concealing of copper pipes of dia 12.7mm od (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. |
| 112 | For 1.50 tonne & For 2 tonne split AC |
| 113 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI- 4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 6 Kgf/cm2 40mm i/d |
| 114 | For 1.50 tonne & For 2 tonne split AC |
| 115 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 116 | 6 kg. Capacity |
| 117 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 118 | 4.5 Kg. Capacity |
| 119 | C.P Jali |
| 120 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect |
| 121 | Size 550 mm x 400 mm x 815 mm |
| 122 | Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 123 | Vitreous chinaware standard white pedestal for wash hand basin. |
| 124 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) complete in all respect |
| 125 | PVC tube connection of size 15 mm x 375 mm with PTMT nut |
| 126 | Providing and fixing PVC Waste pipe Collapsiable 32 mm complete in all respect. |
| 127 | Providing & Fixing in position C.P. Brass extension piece 25 mm long to 100 mm long of approved make (to the approval of Engineer-in-charge) with various fixtures complete in all respect. |
| 128 | C.P Brass extention piece, 25mm long to 50mm long |
| 129 | Providing and fixing in position automatic brass Ball Cock in tanks. |
| 130 | Brass Ball Cock with rod and Plastic Ball.25 mm i/d |
| 131 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and base support for tank |
| 132 | Triple Layer Tanks |
| 133 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 134 | G.I. tank nipple 25 mm i/d |
| 135 | G.I. tank nipple 32 mm i/d |
| 136 | Construction of Platform for placing PVC Water Storage Tank with Brick Ballast Work, Plaster, CC 1:8:16, CC 1:2:4, cement rendering etc. of required size complete in all respect. |
| 137 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 138 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 139 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 140 | Size 75 mm x 75 mm |
| 141 | Cutting holes up to 23 cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 142 | Through wall 11.43 cm thick |
| 143 | Through wall 22.86 cm thick |
| 144 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 145 | 20 mm i/d Brass Ball valves |
| 146 | 25 mm i/d Brass Ball valves |
| 147 | Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge)including cutting, jointing, wastage, but excluding cost of lead jointing. |
| 148 | 110 mm o/d SWR UPVC pipe line laid complete |
| 149 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150 mm x 150 mm , cover and frame clear opening 300 mm x 300 mm and out of side size 330 mm x 330 mm and chamber including cost of all bricks work in cement mortar 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50 mm. |
| 150 | 100 mm internal Diameter S.W. Gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300 mm x 300 mm and out of side size 330 mm x 330 mm |
| 151 | Construction of brick masonry inspection chambers size as given below up to 0.60 metre average depth in 1:5 cement sand mortar, lime concrete with 40 per cent lime mortar 2:3 in foundation, cement concrete 1:2:4 benching 12.50 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping 50 mm thick with 455 mm x 455mm, 455 mm x 610 mm inside light duty C.I. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 152 | Size 450 mm x 450 mm inside with RCC 455 mm x 455 mm cover and frame light duty double seal |
| 153 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 154 | CPVC SDR 11 Pipe & fitting 20mm o/d |
| 155 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 156 | CPVC SDR 11 Pipe & fitting 32mm o/d |
| 157 | Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineerin- charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect. |
| 158 | Size 470mmx370mmx180mm |
| 159 | Providing and fixing in postion storage type automatic electric water heater pressure / non pressure type thermostatically controlled, single phase, vertical wall mounted of approved make (to the approval of Engineer-incharge) with thermostats, inner container of stainless steel complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. |
| 160 | 25 litre capacity water heater |
| 161 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 162 | Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity(without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect. |
| 163 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 164 | For 110mm o/d pipes |
| 165 | Single Tee |
| 166 | Door Elbow 90 Degree (All side socketed) |
| 167 | P Trap/Floor Trap 110mm x 110mm |
| 168 | Single Y-Junction |
| 169 | Providing and fixing 15 mm CP brass labortary cock swan neck of approved make (to the approval of engineer0in-charge) complete in all respect. |
| 170 | Laboratroy cock swan neck one day |
| 171 | Laboratroy cock swan neck two way |
| 172 | Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect. |
| 173 | Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 174 | 32mm i/d Gun mettal peet valve heavy pattern |
| 175 | Construction of Septic Tank size 2.44 Mtr x 1.52 Mtr. Internal size with 1.83 Mtr. Internal depth in brick masonary, 2 no. Chambers medium duty man hole cover complete as per drawing / specification and to the entire satisfaction of Engineer-in-charge. (Rate as Per Analysis Attached) |
| 176 | Construction of soakage pit 1.50 m Diametre & 3.07 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design.( Rate as Per Analysis Attached) |
| 177 | Providing fixing and jointing GI union couplings (of approved make with the approval EIC) as per IS 1879 GI pipe line complete in all respect. |
| 178 | 20 mm i/d GI union |
| 179 | 25 mm i/d GI union |
| 180 | 32 mm i/d GI union |
| 181 | ELECTRICAL WORKS |
| 182 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 183 | Wiring fan point (With fan box) |
| 184 | Wiring light point |
| 185 | Wiring call-bell point |
| 186 | Wiring 6 Amp. wall socket point |
| 187 | Wiring 6 Amp. Plug control comprising wall socket point |
| 188 | Wiring 16/20 amp. power plug control point |
| 189 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 190 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 191 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 192 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 193 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 194 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 195 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 196 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 197 | Wiring Telephone socket point RJ11 (one module) |
| 198 | Wiring Networking socket point RJ45 (one module) |
| 199 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 200 | Overall size 1sq.mm (Un-sheathed) |
| 201 | Overall size 1.5sq.mm (Un-sheathed) |
| 202 | Overall size 2.5sq.mm (Un-sheathed) |
| 203 | Overall size 4sq.mm (Un-sheathed) |
| 204 | Overall size 10sq.mm (Un-sheathed) |
| 205 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): |
| 206 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 207 | Overall size 6sq.mm (2Core) Un-armoured (On-Surface) |
| 208 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 209 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (LOOSE) as per PWD General Specifications:- |
| 210 | Overall size 10sq.mm (4Core) Un-armoured (Loose) |
| 211 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 212 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 213 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 214 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 215 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 216 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 217 | PVC flexible pipe 25mm dia. |
| 218 | Copper Earthing |
| 219 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 220 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 221 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 222 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 223 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 224 | Ceiling Rose (Flush Piano type) |
| 225 | Bakelite Batten Holder (Large size) |
| 226 | MCB'S & MCB DISTRIBUTION BOARDS: |
| 227 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 228 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 229 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 230 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 231 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 232 | SP&N Double Door Distribution Board 8 way each |
| 233 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 234 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES: |
| 235 | Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:- |
| 236 | ICDP Changeover Switch 63amp., 415volts |
| 237 | SINGLE ARM BRACKETS FOR GI PIPE POLE: |
| 238 | Supply and erection of G.I. Pipe (A-Class) Single arm bracket of suitable length to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the existing surface/ wall with 2nos. MS flat clamp 25mm x 5mm, 30cm long and 4nos. fastner 10mm x 75mm long with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:- |
| 239 | Single Arm Bracket 1 metre Long G.I. Pipe 40mm Dia. |
| 240 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 241 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 242 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 243 | Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear ( IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021 |
| 244 | Supply and erection of 3 star rating Ceiling Fan 1200mm (48\\") with double ball bearing copper wound, full aluminium body, 3 no. of blades, white in colour including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. |
| 245 | Supply and erection of Venti Air Fan 250mm with aluminium louver shutter longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 246 | SITC of Wall Fan Size 400MM complete in all respect as approved and desired by the Engineer in-charges at site. |
| 247 | Supply ,erection,testing & commissioning of Pure Sine Wave Invertor 2000VA with 24month warranty with Ttolley for Two tall tubular batteries,connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. |
| 248 | Supply ,erection,testing & commissioning of 12volt- 200 AH Tall Tubular Battery with warranty 36 months including connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. |
| 249 | Supply,Installation and Comissioning of Frost Free Double Door Refrigerator capacity 235 / 245 Ltr complete in all respect. The Refrigerator shoud also conform to technical specifications attached herewith. Complete in all respect as approved and desired by the Engineer in-charges at site. |
| 250 | Providing -2Way Phone, Patient Token System,Local Area Networking:- |
| 251 | Supply Installation Testing and Commissioning of 16 port 10/100 PoE switch, 8*10/100 PoE port + 2 10/100 uplink, power budget 120W, IEEE 802.3af/at extended range 250 mtr complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 252 | SITC of Token Calling Display System having screen size 4 inches, Voice calling with Bell System, complete key pad Etc, calling display up to 60 meter cable (15 meter length included), serial communication design, Text Color Red Display Shape Rectangle, Power 5 W, Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital, Cash counter, Tehsil, Courts etc, Warranty 1 Year,220 VAC Operating Voltage character Capacity 3 Character, Power Consumption, Rectangular Metal body complete in all respects as desired by the Engineer in charge of work at site.. |
| 253 | Supply & installation of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks complete in all respects as desired by the Engineer in charge of work at site. |
| 254 | Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. |
| 255 | Supply, installation, testing & commissioning of Category 6 UTP , 4 Pair This cable well exceeds the requirements of TIA/EIA-568-C.2 and IEC/ISO 11801. Construction: 4 twisted pairs separated by cross separator, 4 channel, polymer spine / full separator. Half shall not be accepted. Operates at bandwidth of 250 MHz, Conductor Solid Bare Electronic Grade Copper. Inner jacket should be PVC and outer should be PE, suitable for direct burial. Insulation: Polyethylene, Attenuation (< 36 db/100m), Pair – to – pair and PS NEXT, ELFEXT and PSELFEXT, Return Loss, ACR and PS ACR., Nominal Outer Diameter of Cable should be 9.70 mm and Conductor Diameter 0.56 mm (23 AWG), Cable should support operating Temperature from -20° to +60°C, Cable should come with printed sequential Length Counter on each meter, Cable support Conductor Resistance 93.5 OHMS/1000MTR |
| 256 | S/I/T/C of intercom facility 1+1 Basic Plan Phone Ringer volume control switch Tone/ Pulse Switchable Redial Mute Flash Pause Intercom facility Call T, Holding the line / Music on Hold during call transfer Line use LED Indication, Secrecy during conversation between both phones, including connecting cables complete in all respect as approved and desired by the Engineer in-charges at site |
| 257 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 258 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 259 | Provision for Branding complete in all respect Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail