|
| 1 | Ground to First Floor- Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. DSR 2023 2.6.1 |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR 2023 2.27 |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : DSR 2023 4.1.8 |
| 4 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per 1S: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:. Concrete of M25 Grade with minimum cement content of 330 kg/cum DSR 2023 5.33A.1 |
| 5 | Steel Reinforcement for RCC work including cutting bending placing DSR 2023 5.22.6 |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns DSR 2023 5.9.1 |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for : Beams DSR 2023 5.9.21 |
| 8 | Centering and shuttering Columns, Pillars, Piers, Abutments, Posts and Struts DSR 2023 5.9.6 |
| 9 | Suspended floors, roofs, landings, balconies and access platform DSR 2023 5.9.3 |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 2023 6.1.1 |
| 11 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : DSR 2023 6.12.2 |
| 12 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. DSR 2023 6.15 |
| 13 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) DSR 2023 13.1.2 |
| 14 | 15 mm cement plaster on the rough side of single or half brick of mix : 1:6 (1 cement: 6 fine sand) DSR 2023 13.2.2 |
| 15 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) DSR 2023 13.16.1 |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 2023 13.80 |
| 17 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR 2023 13.46.1 |
| 18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4..... Size of Tile 600mm x 600mm DSR 2023 11.41.2 |
| 19 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be B62specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting..... DSR 11.37A |
| 20 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. DSR 2023 10.31 |
| 21 | Float glass panes DSR 9.7.7- 4 mm thick glass pane (weight not less than 10kg/sqm). DSR 9.7.7.1 |
| 22 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and......30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DSR 2023 9.20.2 |
| 23 | EARTH FILLING WORK: Construction of embankment with material obtainded from burrowpit. Material obtained with all lift and heads transporting to site 8.00km spreading grading to required slope and compacting to proper requirment of table 300-2 of MORTH (Analysis Rate) |
| 24 | FIRST TO SECOND FLOOR- Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per 1S: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:. Concrete of M25 Grade with minimum cement content of 300 kg/cum (All Works above plinth level upto floor V level) DSR 2023 5.33.2.1 |
| 25 | Steel Reinforcement for RCC work including cutting bending placing DSR 2023 5.22.6 |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form work for : Beams DSR 2023 5.9.21 |
| 27 | Centering and shuttering Columns, Pillars, Piers, Abutments, Posts and Struts DSR 2023 5.9.6 |
| 28 | Centering and shuttering Suspended floors, roofs, landings, balconies and access platform DSR 2023 5.9.3 |
| 29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : DSR 2023 6.4.2 |
| 30 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : DSR 2023 6.12.2 |
| 31 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. DSR 2023 6.15 |
| 32 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) DSR 2023 13.1.2 |
| 33 | 15 mm cement plaster on the rough side of single or half brick of mix : 1:6 (1 cement: 6 fine sand) DSR 2023 13.2.2 |
| 34 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) DSR 2023 13.16.1 |
| 35 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 2023 13.80 |
| 36 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR 2023 13.46.1 |
| 37 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4..... Size of Tile 600mm x 600mm DSR 2023 11.41.2 |
| 38 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be B62specified by the manufacturer) of approved makein all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting..... DSR 11.37A |
| 39 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. DSR 2023 10.31 |
| 40 | Float glass panes DSR 9.7.7 4 mm thick glass pane (weight not less than 10kg/sqm). DSR 9.7.7.1 |
| 41 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and......30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DSR 2023 9.20.2 |
| 42 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per 1S: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:. Concrete of M25 Grade with minimum cement content of 300 kg/cum (All Works above plinth level upto floor V level) DSR 2023 5.33.2.1 |
| 43 | Steel Reinforcement for RCC work including cutting bending placing DSR 2023 5.22.6 |
| 44 | Centering and shuttering including strutting, propping etc. and removal of form work for : Beams DSR 2023 5.9.21 |
| 45 | Centering and shuttering Columns, Pillars, Piers, Abutments, Posts and Struts DSR 2023 5.9.6 |
| 46 | Centering and shuttering Suspended floors, roofs, landings, balconies and access platform DSR 2023 5.9.3 |
| 47 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : DSR 2023 6.4.2 |
| 48 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : DSR 2023 6.12.2 |
| 49 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. DSR 2023 6.15 |
| 50 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) DSR 2023 13.1.2 |
| 51 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment........... DSR 2023 22.7.1 |
| 52 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin-Charge. DSR 2023 16.78.2 |
| 53 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.. DSR 2023 16.68 |
| 54 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil (D.S.R 2.6.1) |
| 55 | Providin of Laying in position cement concrete of specified grade 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). (D.S.R 4.1.8) |
| 56 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (D.S.R.5.1.2) |
| 57 | Steel Reinforcement for R.C.C work including cutting,straightening, bending, binding and placing in position & including complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. (D.S.R.5.22.6) |
| 58 | Same as above in item No 10 but in super structure for wall of one brick thickness Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) (D.S.R.6.4.2) |
| 59 | 12 mm thick plaster with 1:6 cement and coarse sand morter on brick work including ranking and joint washing and cleaning and including supply of all materials labour and T&P etc. required for proper completion of work. (D.S.R.13.4.2) |
| 60 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade.New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (D.S.R.13.47.1) |
| 61 | Finishing with Deluxe Multi Surface Paint .for interiarior or exterior using primer as per manufactures specification. Painting wood work with deluxe multi Multi Surface Paint required shade. to or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (D.S.R.13.48.2) |
| 62 | WBM Grading 3 Providing, laying, spreading and compacting stone aggregatesof specific sizes to water bound macadam specification including spreading inuniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN instages to proper grade and camber, applying and brooming, stone screening to fillup the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. |
| 63 | Cement Concrete Pavement Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 |
| 64 | Construction of Subgrade and Earthen Shoulders- Earth work in cutting or in embankment in ordinary soil, excavation to be in the form of regular pits not exceeding 0.5m in depth and earthwork in embankment to be in 20cm. layers, including ramming and dessing the surface to required levels & slopes & also including 1.5m. lift & 30m. lead. The earth from cutting to be used in making embankment or to be deposited as spoil banks within 30m. Distance as directed by the engineer-in-charge. |
| 65 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. As Per Morth. S.I.No. 12.1 Clause. 304 |
| 66 | Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(GST will be paid extra as applicable) |
| 67 | RCC Grade M25 Using concrete mixer (in Drain) |
| 68 | Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawing and technical specifications As per SI n. 504 |
| 69 | ELECTRICAL WORK- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 70 | Wiring for light/power plug with 2X4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 71 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.-2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire |
| 72 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.- 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire |
| 73 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required. 2 X 4 sq.mm + 1 X 4 sq.mm earth wire |
| 74 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.-2 X 6 sq.mm + 1 X 6 sq.mm earth wire |
| 75 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 76 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door |
| 77 | Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. |
| 78 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB - Single pole |
| 79 | Supplying and fixing single pole blanking plate in the existing MCB DB |
| 80 | Providing and fixing 100 A, 30KA, FP MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board |
| 81 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A |
| 82 | Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A |
| 83 | Supply and fixing of 40 Amp. FP MCB (10 KA) C Curve. CAT A |
| 84 | Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A |
| 85 | Supplying and fixing 40 A, four pole, 415 V, 30 mA RCCB in existing MCB DB |
| 86 | Supplying and fixing 63 A, four pole, 415 V, 30 mA RCCB in existing MCB DB |
| 87 | Providing and fixing M.V. danger notice plate 200 mm X 150 mm |
| 88 | Supplying and drawing 2 Pair 0.5 sqmm FR PVC insulated annealed copper conductor telephone cable |
| 89 | Supplying and drawing co-axial TV cable RG-6 graded |
| 90 | Supplying and fixing Telephone socket outlet (modular) |
| 91 | Supplying and fixing TV antenna socket outlet (modular) |
| 92 | Supplying and fixing metal box 75mm X 75 mm X 60mm Deep |
| 93 | Supplying and fixing 1 or 2 Module (75mm X 75 mm) GI box along with modular base & cover plate |
| 94 | Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes |
| 95 | Supplying and fixing modular blanking plate |
| 96 | Providing, laying and fixing 100 mm Dia RCC pipe NP2 class (light duty) in ground |
| 97 | Supply & fixing of single wall light bracket made of brass on matching polished MDFEG board brass including connection etc. as required. CAT AAA |
| 98 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube. CAT-AAA |
| 99 | Supply and burying of 600mm x 600 mm x 6mm G.I. plate earthing complete |
| 100 | Supply and burying of 40mm dia x 4.5 metres long G.I. pipe earthing complete |
| 101 | Supplying & Laying of 25mmx3mm G.I. Strip for earthing |
| 102 | Supply & fixing of two number 8 SWG G.I. wire for earthing |
| 103 | Supply and fixing of surface/flush mounting 6 way TPN distribution board with additional metal door without MCB. CAT A |
| 104 | Supply & fixing of Crimping, solderless, copper tin electroplated lugs for 1.5 sqmm to 6 sqmm cables |
| 105 | Supply and fixing of single pole MCB blanking plate. CAT B |
| 106 | Erection and testing of ceiling fan and regulator (room height upto 3.5 mts) including supply of 3mm thick G.I. down rod |
| 107 | Erection and testing exhaust fan on the existing hole with suitable size of rag bolts etc. |
| 108 | Supply & fixing of 16 gauge M.S. drum duly painted for exhaust fan |
| 109 | S/F of hexagonal fan box with hexagonal side fabricated from 16 SWG M.S. sheet |
| 110 | Supply & fixing of electronic fan regulator (Modular) 120-280 V. ISI marked |
| 111 | Supply and laying of aluminium conductor PVC insulated armoured cable 35 sqmm 3.5 core |
| 112 | Supply and laying of aluminium conductor PVC insulated armoured cable 10 sqmm 2 core |
| 113 | Supply & fixing of brass nickel plated compression gland for 35 sqmm 3.5 core cable |
| 114 | Supply & fixing of brass nickel plated compression gland for 10 sqmm 2 core cable |
| 115 | Supplying and fixing of Palm/pin type copper tin plated lugs for 35 Sq.mm cable |
| 116 | Supplying and fixing of Palm/pin type copper tin plated lugs for 10 sqmm cable |
| 117 | Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E. rules |
| 118 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting |
| 119 | Supply, installation, testing and commissioning of electrical Meter Panel Board (complete detailed specification as per document) |
| 120 | Supply & erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceiling fan with standard down rod |
| 121 | Supply & erection of AC 230/250 Volts, 50 Hz 300mm sweep exhaust fan complete with accessories |
| 122 | SANITARY WORK- Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern... |
| 123 | White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 124 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid… |
| 125 | W.C. pan with ISI marked black solid plastic seat and lid |
| 126 | Providing & fixing white vitreous china wash basin with C.I. brackets... a) White Vitreous China Flat back wash Basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 127 | Providing and fixing P.V.C. waste pipe for sink or wash basin… Semi rigid pipe 32 mm dia |
| 128 | Semi rigid pipe 40 mm dia |
| 129 | Providing and fixing 600x450mm bevelled edge mirror... |
| 130 | Providing and fixing Stainless Steel AISI 304 kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 131 | Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 132 | Providing and fixing C.P. brass bib cock 15 mm nominal bore |
| 133 | Providing and fixing C.P. brass long body bib cock 15 mm nominal bore (≥690 gms) |
| 134 | Providing and fixing C.P. brass angle valve 15 mm nominal bore |
| 135 | Providing and fixing C.P. brass shower rose 150 mm diameter |
| 136 | Providing and fixing C.P. brass stop cock (concealed) 15mm nominal bore |
| 137 | Providing & fixing soil, waste and vent pipes: 100mm dia centrifugally cast iron S & S pipe |
| 138 | 75mm dia centrifugally cast iron S & S pipe |
| 139 | Providing lead caulked joints: 100mm |
| 140 | Providing & fixing M.S. holder bat clamps… for 100mm dia pipe |
| 141 | for 75mm dia pipe |
| 142 | Providing and laying cement concrete 1:5:10 around P.V.C Soil and waste pipe… 100 mm dia |
| 143 | 75 mm dia |
| 144 | Providing & fixing cast iron trap... 100mm inlet & 75mm outlet |
| 145 | Providing & fixing cast iron coller: 100mm dia |
| 146 | 75mm dia |
| 147 | Providing and fixing plain cast iron S & S sanitary bend: 100mm |
| 148 | Providing and fixing centrifugally cast iron single equal plain junction: 100x100x100mm |
| 149 | 75x75x75mm |
| 150 | Providing and fixing cast iron terminal guard: 100 mm |
| 151 | 75 mm |
| 152 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes 110 mm |
| 153 | Bend 87.5 degree |
| 154 | Shoe (Plain) |
| 155 | Providing and fixing unplasticised-PVC pipe clips 110 mm |
| 156 | Making khurras 45x45 cm with cement concrete... |
| 157 | Providing and fixing CPVC pipes (internal work - Exposed on wall): 15mm dia nominal bore |
| 158 | 20mm dia nominal bore |
| 159 | 25mm dia nominal bore |
| 160 | 32mm dia nominal bore |
| 161 | Providing and fixing GI Union in GI pipes: 15mm dia |
| 162 | 20mm dia |
| 163 | 25mm dia |
| 164 | 32mm dia |
| 165 | Providing and fixing gun metal gate valve: 25mm dia |
| 166 | 32mm dia |
| 167 | Providing and fixing brass stop cock: 15 mm nominal bore |
| 168 | 20 mm nominal bore |
| 169 | Providing and placing on terrace 2000 Ltrs polyethylene water storage tank ISI marked |
| 170 | Excavating trenches... Pipes exceeding 80mm but not exceeding 300mm |
| 171 | Providing, laying and jointing glazed stoneware pipes: 100mm diameter |
| 172 | 150mm diameter |
| 173 | Providing and laying cement concrete 1:5:10 all round S.W. pipes: 100mm dia SW pipe |
| 174 | 150mm dia SW pipe |
| 175 | Providing and fixing square-mouth S.W. gully trap 150 x 100 mm P type with Sewer bricks |
| 176 | Constructing brick masonry manhole 90x80cms and 45cms deep... With FPS bricks (For Sewer Line) |
| 177 | Providing M.S. foot rests... With 20x20 mm square bar (First set) |
| 178 | Providing M.S. foot rests... With 20x20 mm square bar (Second set) |
| 179 | Providing and fixing PTMT towel rail 600 mm long |
| 180 | Providing and fixing PTMT soap Dish Holder |
| 181 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube... |
| 182 | Providing and fixing C.P. brass Two-way angle valve 15 mm nominal bore |
| 183 | Providing & fixing Jaquar make C.P. brass bottle trap Please Enable Macros to View BoQ information |