| 1 | Struking of existing PCC/ Cement floor surface 10 to 15 mm deep picking,sweeping, clean and washing down with water to remove dust to receive cement mortar/ PCC for flooring ,including removing old APP membrane with cement debris and rubbish off the premises complete all as specified and directed. |
| 2 | M&L for Cutting grooves in brick wall,/ RCC wall 75mm wide and 40 -60 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 3 | M&L for PCC 1:3:6 type B-1(using 20mm graded stone aggregate) for providing cement concrete as levelling and roof kerbs or mud stops, including finishing the surface with grinder to receive the acrylic based water proofing material, rounded or chamfered on edges etc complete all as specified and directed. |
| 4 | M&L for rendering or bedding layer 15mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with WPC 2% wt of cement inclduing finishing surfaces even and fair without using extra cement complete all as specified and directed.(Note: WPC will be measured and paid separately ) ( Items Will be Executed while concrete of item no 03 is still green) |
| 5 | M&L for preparation of new surface and applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm complete all as specified and directed. |
| 6 | M&L for APP based polymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove febrick (Weight not less than 150gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer.complete all as specified and directed. |
| 7 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm ) 9 to 10 mm thick with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and loped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 oarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting in the same manner complete all as specified and directed |
| 8 | Supply only Integral waterproofing compound complete all as specified and directed. Make Dr Fixit/ Pidipfoor/ LW+. |
| 9 | M&L for PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregates) as in roof kerbs, Chajja of window/ventilator or mud stops, rounded or chamfered on top of chajja & side edges of surfaces upto the height of 7.00 mtr etc complete all as specified and directed. { The rate is deemed to be inclusive of scaffolding/form work } |
| 10 | Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and forecast concrete articles, complete all as specified and directed. |
| 11 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. |
| 12 | Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed |
| 13 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, finished even and fair without using extra cement complete all as specified and directed |
| 14 | M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over new plaster surfaces of walls complete all as specified and directed. |
| 15 | M&L for complete removal of existing treatment and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over old surfaces of walls complete all as specified and directed. |
| 16 | Dismantling tanks water tank exc 250 but n exc 500 ltr.complete all as specified and directed. |
| 17 | Dismantling tanks water tank exc 500 but n exc 1000 ltr.complete all as specified and directed. |
| 18 | S&F for rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed top), triple layer construction, in white colour ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with fitting etc. of 20 mm dia directed complete all as specified and as directed. |
| 19 | S&F for rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed top), triple layer construction, in white colour ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with fitting etc. of 20 mm dia directed complete all as specified and as directed. |
| 20 | S&F for ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and as directed. |
| 21 | S&F for Stop valves/Gate valves 20 mm dia cast copper alloy,screwed down, high pressure with crutch or butterfly handel, screwed both ends for iron pipe or for unions and fixed.complete all as specified and directed. |
| 22 | Taking up or down old steel tubing 15 mm dia complete all as specified and directed. |
| 23 | Taking up or down old steel tubing 20 mm dia complete all as specified and directed. |
| 24 | S&F for 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors including taking up or down old steel tube complete all as specified and directed. |
| 25 | S&F 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors including taking up or down old steel tube complete all as specified and directed. |
| 26 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories). |
| 27 | S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed |
| 28 | S&F for PVC SWR (110) bends any radius comlete all as specified and directed. |
| 29 | S&F for stack clamps out of 50mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roofs for bore of 100mm complete all as specified and directed. |
| 30 | S&F for 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valleygutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed. |
| 31 | Schedule of Credit (MINUS) Rs. 17,500.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |