Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 2 | Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and gravel mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. |
| 3 | (a)Upto 1.5mtr Depth |
| 4 | Main Building |
| 5 | Guard wall |
| 6 | RCC Drain |
| 7 | Excavation of founation in laterite rock or any hard rock (other than granite or disintigrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department |
| 8 | Upto 1.5mtr Depth |
| 9 | Main Building |
| 10 | Guard wall |
| 11 | From 1.50 to 3.0 m Depth |
| 12 | Main Building |
| 13 | Guard wall |
| 14 | Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. |
| 15 | Main Building |
| 16 | Guard wall |
| 17 | RCC Drain |
| 18 | Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge. |
| 19 | Main Building |
| 20 | Guard wall |
| 21 | RCC Drain |
| 22 | Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. |
| 23 | ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work. |
| 24 | Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. |
| 25 | Main Building |
| 26 | Guard wall |
| 27 | RCC Drain |
| 28 | Paver Pathway |
| 29 | PCC WORK |
| 30 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 31 | Beyond 1.5 M to 4.5M Depth |
| 32 | Main Building |
| 33 | Guard wall |
| 34 | Ground Floor |
| 35 | Main Building |
| 36 | RCC Drain |
| 37 | Paver Pathway |
| 38 | RCC WORK |
| 39 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. |
| 40 | (A)R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. |
| 41 | Up to 1.5 M |
| 42 | RCC Drain |
| 43 | Ground Floor |
| 44 | Main Building |
| 45 | Guard wall |
| 46 | (C)R.C.C. Grade Beams etc. |
| 47 | Ground Floor |
| 48 | (C)R.C.C. Beams, columns, grider and bressmer etc. |
| 49 | Ground Floor |
| 50 | First Floor |
| 51 | Second Floor |
| 52 | Terrace Floor |
| 53 | (D)R.C.C. Floor and Roof slab, landing, balconies,Projecting sun shades and chajjas up to 4.3Mtr. Height. |
| 54 | Ground Floor |
| 55 | Main Building |
| 56 | RCC Drain |
| 57 | First Floor |
| 58 | Second Floor |
| 59 | Terrace Floor |
| 60 | (E)R.C.C. stairs excluding landing but including railing. |
| 61 | Ground Floor |
| 62 | First Floor |
| 63 | Second Floor |
| 64 | (G)R.C.C. Lintel |
| 65 | Ground Floor |
| 66 | First Floor |
| 67 | Second Floor |
| 68 | Terrace Floor |
| 69 | (I)R.C.C. Wall |
| 70 | Ground Floor |
| 71 | Guard wall |
| 72 | RCC Drain |
| 73 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). |
| 74 | Guard Wall |
| 75 | RCC Drain |
| 76 | Ground Floor |
| 77 | Main Building |
| 78 | Guard wall |
| 79 | First Floor |
| 80 | Second Floor |
| 81 | Terrace Floor |
| 82 | BRICK WORK |
| 83 | Providing and laying Brick masonry work in Superstructure using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. ( Excluding Cost of Steel Reinforcement ) |
| 84 | First Floor |
| 85 | Second Floor |
| 86 | Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. |
| 87 | Ground Floor |
| 88 | First Floor |
| 89 | Second Floor |
| 90 | Terrace Floor |
| 91 | FINISHING WORK |
| 92 | Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge. |
| 93 | Ground Floor |
| 94 | First Floor |
| 95 | Second Floor |
| 96 | Terrace Floor |
| 97 | Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. |
| 98 | First Floor |
| 99 | Second Floor |
| 100 | Providing 12mm thick Cement Plaster to the Surface of Brick Masonry Wall in Cement Mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge.(Inside Even Surface) |
| 101 | Ground Floor |
| 102 | Main Building |
| 103 | Guard Wall |
| 104 | First Floor |
| 105 | Second Floor |
| 106 | Terrace Floor |
| 107 | Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.(Inside Uneven Surface) |
| 108 | Providing 18mm thick cement plaster on external surfaces of brick surfaces in two coats consisting of under layer 12mm thick in CM 1:6 (1 cement : 6 coarse sand) and top layer of 6mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. |
| 109 | Ground Floor |
| 110 | First Floor |
| 111 | Second Floor |
| 112 | Terrace Floor |
| 113 | Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound (Make: Sika / Fosroc / Equivalent) after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. |
| 114 | Terrace Floor |
| 115 | Providing and carry out waterproofing treatment to sound, moisture free concrete surface using Nitoproof 600PF - Liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100-Plasticised expandive grout admixture supplied in 225 gm pouch, application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet using Conbextra GP2 - Non-shrink cementitious grout, application of Nitoproof WB Primer @ 8-10sqm/litre afetr dilution and application of two coats of Nitoproof 600PF coverage @ 2.0 kg/m2 to achieve 1.5 mm thickness in two coats followed by laying of seperation layer of 120 gsm non-woven geotextile layer before carry out protection screed etc. |
| 116 | complete including all tools and tackles as per manufacturer’s specification. Nitocote 600PF cured material shall be having crack bridging of 2 mm, Elongation (ASTMD 412) – >600 %, Tensile Strength (ASTM D412) – 2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, 85% Solid Content, Tear Resistance (ASTM D624) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 60, Water vapour transmission- 0.6 g/m2/hr, Water Permeability @ 5 Bar (BS EN 12390)-Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C, Viscosity-60p, Specific Gravity-1.5. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation, grouting, ponding test, placing of 120gsm non-woven geotextile etc. complete as per design, drawing & instructions of EIC. Cost of Protective Screed concrete will be paid separately. |
| 117 | (a)Terrace Floor |
| 118 | FINISHING WORK |
| 119 | Supplying and finishing the Inside plastered surface of wall using cement based wall putty (Water based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge.(Make: Birla White/J K Wall Putty) |
| 120 | I. Internal Putty |
| 121 | Ground Floor |
| 122 | First Floor |
| 123 | Second Floor |
| 124 | Terrace Floor |
| 125 | Supplying and finishing the Outside plastered surface of wall using cement based wall putty (Water based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge.(Make: Birla White/J K Wall Putty) |
| 126 | II. External Putty |
| 127 | Ground Floor |
| 128 | First Floor |
| 129 | Second Floor |
| 130 | Terrace Floor |
| 131 | Providing and applying Two Coats Plastic Emulsion Paint of approved make, quality and shade over a coat of wall primer of approved quality to the internal plastered surfaces including throughly brushing the surface to make free from foreign materials, sand papering, priming including cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the direction of the Engineer-in-charge.(Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) |
| 132 | Ground Floor |
| 133 | First Floor |
| 134 | Second Floor |
| 135 | Terrace Floor |
| 136 | Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer make an even finished surface over a coat of water bound cement primer and wall putty in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete.(Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) |
| 137 | Ground Floor |
| 138 | Main Building |
| 139 | Guard Wall |
| 140 | First Floor |
| 141 | Second Floor |
| 142 | Terrace Floor |
| 143 | Providing and painting Two Coats of Synthetic Enamel Paint of approved quality, brand and shade over a coat of red oxide primer to Iron Work including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) |
| 144 | Ground Floor |
| 145 | First Floor |
| 146 | Second Floor |
| 147 | FLOORING WORK |
| 148 | Providing and laying of 600 mm x 600 mm Matt Finished Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/Kajaria) |
| 149 | First Floor |
| 150 | Second Floor |
| 151 | Providing and laying of Vitrified Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.)(Make:Somany/Jhonson/RAK/Kajaria) |
| 152 | First Floor |
| 153 | Second Floor |
| 154 | Providing and laying 600 mm x 600 mm matt finish Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and spacer of 4mm for grouting the joints of tiles using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.)(Make:Somany/Jhonson/RAK/Kajaria) |
| 155 | Toilet Water Proofing |
| 156 | Toilet Wall & Floor - Providing Cleaning the rooftop/sunken surface by using1. Water Proof Coating- Cold applied water based modified polyurethane hybrid elastomeric waterproof membrane at minimum 0.8mm dft in one coat having solids by volume:620/o, Tensile Strength ASTMD412:1.75MPa, elongation ASTMD412>350%, Tear Strength ASTMD624: 13N/mm, Adheshion to substrate; 1.9MPa concrete, Crack Bridging static/dynamic:2mm ASTM C836, Resistance to water: 10m pressure & SRI ValuelOG for white to be used on the roof including parapet wall surface as per manufacturer direction.2. Coving at right angle- All right angle junctions between floor and wall shall be provided with coving of size 75mmx75mm minimum 15mm thickness in cement mortar 1:4 admixed with FOSROC/SIKA/equivalent chemicals @ 2 litres per 50kg of cement after saturating the surface with water and applying a slurry primer coat.3. Protective Coating- Providing and applying PU Coating FOSROC/SIKA/equivalent on the applied waterproofing surface as per manufacturer direction.(Make:MYK / Fosroc /Tremco Pvt.Ltd./Pidilite /Sika) |
| 157 | Providing and laying of Glazed Ceramic Wall Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.)(Make:Somany/Jhonson/RAK/Kajaria) |
| 158 | Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade with typical half nosing and cutting grooves etc including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (Colour: Tan Brown)(Note- Sample of granite tiles shall be approved before procurement and use.) |
| 159 | Ground Floor |
| 160 | First Floor |
| 161 | Second Floor |
| 162 | Providing & laying granite stone flooring in Floors and landing using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) |
| 163 | Ground Floor |
| 164 | First Floor |
| 165 | Second Floor |
| 166 | Terrace Floor |
| 167 | Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) |
| 168 | Ground Floor |
| 169 | First Floor |
| 170 | Second Floor |
| 171 | Terrace Floor |
| 172 | Providing and laying 62 mm thick cement concrete flooring with Hardener topping comprising of an under layer of 50 mm thick cement concrete of mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agrregate 20 mm nominal size) and 12 mm thick cement hardener topping layer of mix 1:2 ( 1 cement hardener mix : 2 parts of screened & washed stone agrregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litres per bag of cement and laying the concrete in alternate panels of 2m x 2m (max) including cleaning the surface to make free from foreign particles, cost of all materials, conveyance, taxes, loading, unloading, royalty, T&P, etc, all complete as per the direction of Engineer-in-Charge. |
| 173 | Ground Floor |
| 174 | BUILT IN JOINERIES |
| 175 | Supplying and installing Aluminium System - Fixed windows made out of ALUPURE/Equivalent make frame dimension of 39mm x 42mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3).Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of MCCOY /Dowcorning or equivalent. or |
| 176 | Supplying and installing Aluminium System - Openable windows made out of ALUPURE/Equivalent make frame dimension of 39mm x 62.9mm & Sash dimension of 46mm x 92mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. or |
| 177 | Supplying and installing Aluminium System - Sliding windows made out of ALUPURE/Equivalent make frame dimension of 88mm x 40 & Sash dimension of 31mm x 61.5mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. or |
| 178 | Second Floor |
| 179 | Terrace Floor |
| 180 | Supplying, fitting & fixing of M.S. Grill made out of M.S. flats/square bars as per drawing and design fixed in position to proper plumb, including a coat of priming with approved quality metallic primer, materials including cost, conveyance, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in charge. |
| 181 | First Floor |
| 182 | Second Floor |
| 183 | S.S Railing |
| 184 | Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. |
| 185 | Ground Floor |
| 186 | First Floor |
| 187 | Second Floor |
| 188 | Supplying,Installation of pressed Steel Doors of the specified dimensions and accessories such as hinges,door stopper,tower bolt, door handle ,door closer,dead lock,consedaled flush bolt,Shaft lock,martise lock and vision panel etc. complete as mentioned along with warranty covverage and after sales service etc.inclusive of all costs,taxes,GST,cost of delivery charges ,fixing,fittings and any other invidential charges etc.complete. |
| 189 | First Floor |
| 190 | 3 nos Hinges,1 no Door Stopper,1 No tower bolt & 1 no Martise Handle(1200x2100) |
| 191 | 3 nos Hinges,1 no Door Stopper,1 No tower bolt & 1 no Martise Handle (900x2100) |
| 192 | Second Floor |
| 193 | 3 nos Hinges,1 no Door Stopper,1 No tower bolt & 1 no Martise Handle(1200x2100) |
| 194 | 3 nos Hinges,1 no Door Stopper,1 No tower bolt & 1 no Martise Handle (900x2100) |
| 195 | Terrace Floor |
| 196 | 4 nos Hinges,1 no Door stopper,1 No tower bolt & 1 no Martise lock (1000x2400) |
| 197 | Structural Glazing,GRC & Roofing |
| 198 | Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer. |
| 199 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). |
| 200 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) |
| 201 | Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. |
| 202 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. |
| 203 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick hard coated low emmissivity glass, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 204 | Providing and carrying out waterproofing treatment for basement walls by using Fosroc Proofex 3000 - 1.5mm thick Self adhesive, cold applied, flexible, high performance membrane incorporating a cross laminated HDPE carrier film with a polymer modified bitumen compound. Proofex 3000 is Suitable for waterproofing basements grades 2, 3 and 4 as defined in BS 8102: 1990, ‘Protection Of Structures Against Water From The Ground. Typical Appication includes surface preparation by removing loose concrete, foreign material etc, application of Proofex Tack coat Primer using suitable brush/roller, allow the same to become tack free. Membrane should be applied to the substrate by first removing the released paper, pressing the film firmly ensuring that the adhesive bitumen compound bonds continuously to the substrate with no air pockets. Membrane must be overlapped by 75 mm at adjacent and 150 mm overlap at the end, termination of the membrane minimum 200 mm above ground level by using Aluminium Termination Strip and top shall be sealed with Nitoseal PU 40 sealant etc. complete Proofex 3000 membrane shall have following typical properties :i) Thickness (mm): 1.5 with roll size 1 m x 20 mii) Adhesion to primed concrete (ASTM D1000) -4.9mmiii) Tensile strength (BS EN 12311-1) Longitudinal -215 N/50mm /Transverse- 220 N/50mmiv)Elongation (BS EN 12311-1) Longitudinal- 324% /Transverse - 238 %v) Water vapour permeability (BS EN 1931) - Impermeable to ISO 12572vi) Resistance to Hydrostatic head : Min 60m (ASTM D 5385)The rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation etc. complete as per design, drawing & instructions of EIC. (Outer wall of Basement & UGR) (Outer wall of Basement & UGR) |
| 205 | Providing and installing two component acrylic modified cementitious waterproofing coating with Masterseal 551 /Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect.Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L |
| 206 | Terrcae Floor |
| 207 | Paver Pathway & Site Filling |
| 208 | Excavation in soil using Hydraulic Excavator CK-90 & Tipper with Disposal upto 1000 metres-Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000 metres. |
| 209 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. |
| 210 | Construction of granular sub-base by providing close graded VI Material, spreading in uniform layers with motor grader on prepared surface,mixing by place in method rotavator at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 |
| 211 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. |
| 212 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 213 | Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 214 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per section 800 of MoRTH specifications for Road & Bridge works (5th revision) and instruction of Engineer in charge. |
| 215 | Construction of embankment with approved materials obtained from borrow pits by mechanical means graded and compacted to meet requirement as per approved drawing and technical specifications complete in all respect as per Section 900 and clause 305 of MoRT&H Specification for Road & Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in- Charge. |
| 216 | Landscaping work |
| 217 | GRASS |
| 218 | Providing and laying Corian Grass /Jayasia Japanica/Selection No.-1/Neelgiri Grass Turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmous) and then rolling the surface with light roller make that surface smoothen and light watering with sprinkler and maintenance for 30days or more till the grasses establish properly, as per direction of officer-in-charge etc. All compete. |
| 219 | SITE PERPARATION |
| 220 | Supplying and stacking of quality garden soil preferably red alluvial / sandy at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment). |
| 221 | Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). |
| 222 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) . |
| 223 | Screened through sieve of I.S. designation 20 mm |
| 224 | Screened through sieve of I.S. designation 16 mm |
| 225 | Screened through sieve of I.S. designation 4.75 mm |
| 226 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 227 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. |
| 228 | ELECTRICAL WORKS |
| 229 | Subhead- I (Internal Electrification) |
| 230 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point. |
| 231 | Group-A: L.P= F.P= C.B.P= |
| 232 | Group-B: L.P= F.P= C.B.P= |
| 233 | Group-C: L.P= F.P= C.B.P= |
| 234 | Supplying and fixing of (for internal wiring) cover plates, moulded frame,Two-way 6A switches, with all accesories and connection as per direction of Engineer in Charge. (modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 235 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 236 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 237 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. |
| 238 | Supplying and fixing including testing and commissioning of 6A modular socket outlet with 6 Amp switch including providing GI modular box with faceplate etc as required.Switch & socket: (modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 239 | 1 nos 6 Amp 3-pin socket with 6 Amp switch. |
| 240 | 2 nos 6 Amp 3-pin socket with 2 nos 6 Amp switch. |
| 241 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 242 | Supplying and installation of 25A AC starter/Gyser Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .(Make-Legrand/Schneider/ Havells/ABB) |
| 243 | Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable/KEI/Gloster) in recessed PVC FRLS conduit HEAVY duty (Make-AKG/Polycab/precision/norpack/sudhakar) of mentioned size as approved) as required as per direction of Engg.-in-Charge. |
| 244 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 245 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 246 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit . (2X4+1X1.5) |
| 247 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5) |
| 248 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(PANEL TO ACDB) (4X10+2X6) |
| 249 | SITC an fixing of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Make: Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years. |
| 250 | SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years (Make: Philips/Wipro /Crompton/Bajaj). |
| 251 | SITC of surface Mounted Led bulk head Lighter comprising of 10W LED BULK HEAD LIGHTwith non integral / integral driver, 6500K color temp having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy > 120 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c connection wire, testing etc. to complete the job. (Make: Philips/Wipro /Crompton/Bajaj) |
| 252 | SITC of Energy efficient surface /recess mounted square /round shape 9W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 9 watt and lumen output of 900 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.(Make: Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 253 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 254 | Supplying, installation, testing and commssioning of BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Technix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. . |
| 255 | 1200 mm sweep |
| 256 | Supplying, installation, of exhaust fan of heavy duty 200 mm sweep with louvers any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement warranty shall be 2 years. Make-Havells/Bajaj/Usha/Crompton /Orient |
| 257 | 200 mm sweep |
| 258 | 2KVA ONLINE UPS |
| 259 | Supply, Installation, Testing & Comissioning of 2 KVA Online UPS IGBT based True Online Smart gxtmt+ Double conversion efficiency UPS and True Online Double Conversion with DSP Control Technology for High Performance with Single phase I/P & Single Phase O/P with 30 Min Back Up on 90 % Running load along MS Battery KBS Rack & Battery inter connection link of accessories for installation.with Suitable Battery Bank for 30 min back up with Sealed Maintenance Free Battery. Make: Amararaja/ Exide/ Kalorie,open type powder coated racks for Battery as per the specification complete as per direction of Engineer in charge(Make: NUMERIC / EMERSON /APC ). |
| 260 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 261 | Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer-In-Charge. Make :-Finolex/Polycab/KEI |
| 262 | Supplying and fixing T.V. antenna socket outlet piano type ISI marked on the existing switchboard / cover including connections etc as requird.(Make :Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) |
| 263 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 264 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /LK -Exora-N as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 265 | 6 Way(8+12+18) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LDB, PDB LOAD) |
| 266 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (For UPS DB for quarter) |
| 267 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years .(GF & COMMON AREA) |
| 268 | Supplying and fixing following rating RCBOs/ MCBs in the existing DB complete with connections,testing and commissioning etc. as required. |
| 269 | Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 270 | Supplying and fixing 40 Amps , 2P, 415 volts, RCCB breaking capacity 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 271 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years.. |
| 272 | Supplying and fixing 32 Amps2P RCBO,30mA rating,C series,Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCBO should be Replacement Warranty will be 1 year |
| 273 | Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Make-AKG/BEC/Precision/Anchor |
| 274 | 20 mm |
| 275 | Supply and laying of 25/32mm U PVC trunking system and acessories.(Make:Legrand/MK(honeywell) |
| 276 | Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored. |
| 277 | FIRE EXTINGUISHER SYSTEM |
| 278 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 279 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex) |
| 280 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 281 | First Aid Box. |
| 282 | Shock Treatment Chart (Odia / Hindi & English). |
| 283 | 8 mm thick Rubber Mat. |
| 284 | Danger Board. |
| 285 | P.H. WORKS |
| 286 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.In 1st Floor-20mm dia C-PVC pipe (Ashirbad/Astral or eqv) |
| 287 | 25mm dia C-PVC pipe (Ashirbad/Astral or eqv) |
| 288 | In 2nd Floor-20mm dia C-PVC pipe (Ashirbad/Astral or eqv) |
| 289 | 25mm dia C-PVC pipe (Ashirbad/Astral or eqv) |
| 290 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.In Ground Floor 25mm UPVC ASTM Pipe |
| 291 | 32mm UPVC ASTM Pipe |
| 292 | In 1st Floor- 25mm dia UPVC ASTM Pipe |
| 293 | 32mm dia UPVC ASTM Pipe |
| 294 | In 2nd Floor- 25mm dia UPVC ASTM Pipe |
| 295 | 32mm dia UPVC ASTM Pipe |
| 296 | In terrace Floor- 25mm dia UPVC ASTM Pipe |
| 297 | 40mm dia UPVC ASTM Pipe |
| 298 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.In Ground Floor |
| 299 | In 1st Floor |
| 300 | In 2nd Floor |
| 301 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.(In G Floor) |
| 302 | In 1st Floor |
| 303 | In 2nd Floor |
| 304 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in charge(In 1st Floor) |
| 305 | In 2nd Floor |
| 306 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall In Ground Floor |
| 307 | In 1st Floor |
| 308 | In 2nd Floor |
| 309 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. (Make: Cera/Jaquar/Hindware or eqv.)15mm dia CP Bib cock (FLR-CHR-5047N Jaquar make) |
| 310 | 15mm dia CP angle stop cock (FLR-CHR-5053N Jaquar make or eqv) |
| 311 | 20mm dia CP consealed stop cock(FLR-CHR-5089N Jaquar or eqv) |
| 312 | 15mm dia CP two in one bib cock (FLR-CHR-5041N Jaquar or eqv) |
| 313 | 15mm dia CP Health faucet (ALD-CHR-573 Jaquar make or eqv) |
| 314 | 15mm dia CP extension piece |
| 315 | 15mm dia CP Flange |
| 316 | 15mm dia CP Pillar cock (FLR-CHR-5011N Jaquar make or eqv) |
| 317 | 15mm dia CP Sink Cock (FLR-ANQ-5357N Jaquar make or eqv) |
| 318 | 20mm dia CP wall mixture (FLR-ANQ-5217 N Jaquar make or eqv) |
| 319 | Revolving Shower with arm Jauar Cat NO--OHS-CHR-1709 or eqv |
| 320 | Corner shelf(Jaquar)CAN-ABR-1173 or eqv |
| 321 | 125mm CP grating |
| 322 | Bottle trap(Jaquar)ALD-CHR-769L or eqv |
| 323 | 25mm dia brass Fullway valve |
| 324 | 32mm dia brass Fullway valve |
| 325 | 40mm dia brass Fullway valve |
| 326 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge On the roof of 2nd floor |
| 327 | 2000 litre capacity water storage Sintex tanks. |
| 328 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge100mm dia U-PVC SWR pipes (Ashirvad/Astral or eqv) |
| 329 | 75mm dia U-PVC SWR pipes (Ashirvad/Astral or eqv) |
| 330 | 50mm dia class IV pipes (Ashirvad/Astral or eqv) |
| 331 | 100mm dia U-PVC 'P' trap |
| 332 | 110mm dia U-PVC Door Tee |
| 333 | 100mm dia U-PVC Plain Bend |
| 334 | 100mm dia U-PVC Door Bend |
| 335 | 100mm U-PVC Door Cross Tee |
| 336 | 75mm dia U-PVC Door Bend. |
| 337 | 75mm dia U-PVC Plain Bend. |
| 338 | 75mm dia Nahin trap |
| 339 | 110x75mm dia Reducer |
| 340 | 110mm dia Vent cowl. |
| 341 | W/C connector |
| 342 | PVC Clamp suitable for 75mm to 110mm dia pipe |
| 343 | Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china Wall mounted water closet Rimless (European pattern) with P Trap with seat cover (solid) of approved make in all floor & consealed Flush tank with frame, flush plate including supply of sutaible bracket, PVC wall plug and Brass screws etc. all complete including cost, conveyance as per specification all complete as per direction of Engineer-in-charge. (In rooms) Make : JAQUAR/HINDWARE/CERA or eqv. Rate as per CERA S1043171,B1110111,B1120101 or equivalent |
| 344 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge. (Cera/Hindware/Jaquar or eqv )Half pedestal Basin(Hindware)No.91049+91115 or eqv |
| 345 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink With sink cock with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge600x450x250 mm SS sink(With drain board -NIRALI) or eqv |
| 346 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) or eqv |
| 347 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge600 x 125mm plate glass shelf with CP guard rails(jaquar) or eqvCAN-ACR-1171NMI |
| 348 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mm x 600mm long CP towel rail (Jaquar)CAN-ANG-1111 or eqv |
| 349 | CP towel rail Ring. (Jaquar) CAN-ANG-1121 or eqv |
| 350 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeCP soap holder (JAQUAR)CAN-ANG-1131N or eqv |
| 351 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 352 | In 1st Floor |
| 353 | In 2nd Floor |
| 354 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. |
| 355 | In 1st Floor |
| 356 | In Second floor |
| 357 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 358 | In First floor |
| 359 | In Second floor |
| 360 | Fitting and fixing Ceramic floor tiles with matt finish Kajaria (Fog Perla) on floors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, royalities and taxes etc. all complete as per direction of Engineer in charge. Cost of Tile Kajaria(Fog Perla) 600x600mm (1st Floor) |
| 361 | In Ist Floor |
| 362 | In 2nd Floor |
| 363 | Fitting and fixing Ceramic wall tiles of Kajaria (Duren Marfil) to dados skirting & risers of steps on 12mm. thick C.P (1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles including cost conveyance, royalities and taxes etc. all complete as per direction of Engineer in charge. Cost of Tile Kajaria(Duren Marfil)600x300 |
| 364 | In First floor |
| 365 | In Second floor |
| 366 | Providing & laying granite stone flooring in Floors and landing using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of granite tiles shall be approved before procurement and use.) |
| 367 | In First floor |
| 368 | In Second floor |
| 369 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 370 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge . |
| 371 | External PH Works |
| 372 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in chargeGully trap chamber of size 250mmx250mm with RCPC Cover |
| 373 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.Inspection chamber Inside size 760mmx760mmx460mm with RCPC Cover |
| 374 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in chargeMan hole chamber Inside size 910mmx910mmx910mm |
| 375 | Cost of R.C.P.C.Cover. |
| 376 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia u-pvc pipe alround concrete |
| 377 | 160mm dia u-pvc pipe alround concrete |
| 378 | Construction 1 nos 30 users RCC Septic tank |
| 379 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 380 | - do - with addl. Depth of 1.5 m |
| 381 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 382 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 383 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 384 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 385 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 386 | Roof Slab |
| 387 | For RCC wall |
| 388 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 389 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 390 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 391 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C. |
| 392 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 393 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 394 | 110mm diameter U-PVC SWR pipe |
| 395 | 110mm dia U-PVC Plain shoe bend |
| 396 | 110mm dia U-PVC Cowl |
| 397 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 398 | Construction of 20000 Liters RCC Under ground Reserver of Inside size- 3.20x3.20x2.50m |
| 399 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 400 | Excavation of founation in laterite rock or any hard rock (other than granite or disintigrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department. Beyond 1.5mtr to 3.00 mtr Depth |
| 401 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 402 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 403 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 404 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 405 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
| 406 | RCC floor roof, chajja etc |
| 407 | RCC Beam, Column, wall etc |
| 408 | RCC Plinth bend/ Raft |
| 409 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site. |
| 410 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 411 | Supplying and fitting and fixing stainless steel 304 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
| 412 | Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge |
| 413 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 414 | De-watering |
| 415 | Submerssible Pump Set 1.00 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 610 L.M.P with outlet dia of 32 mm. |
| 416 | DOL control panel |
| 417 | 2.50 sqmm cable |
| 418 | 32mm dia steel short piece |
| 419 | 32 mm dia HDPE Pipe |
| 420 | Rope Wire Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail