Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKS Dismantling Floor tiles (to be carefully removed).(CSR 8.35) |
| 2 | Dismantling of cement ConcreteCement concrete plain 1:4:8 or 1:5:10 (CSR 8.6 b) |
| 3 | Scraping of Cement Plaster (CSR 8.31 c) |
| 4 | Dismantling brick or flagged stone flooringincluding concrete base. (CSR 8.18) |
| 5 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.(CSR 6.6) |
| 6 | Cement concrete 1:5:10 mixing by mechanical means using concretemixer volumetric type. (CSR 10.9 a (ii)) |
| 7 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth (CSR 11.5) |
| 8 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (CSR 10.15) |
| 9 | Damp proof course 2.5cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded. (CSR 10.28) |
| 10 | Shuttering for faces of concrete foundations and foundation beam & plinth beamb (vertical or battering). (CSR 9.1) |
| 11 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. (CSR 18.18) |
| 12 | First class burnt brick wall laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. (CSR 11.6) |
| 13 | Diffrence in Rate of Brick Work |
| 14 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure. (CSR 11.36) |
| 15 | Diffrence in Rate of Brick Work |
| 16 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. (CSR 9.8) |
| 17 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. (CSR 9.6) |
| 18 | RCC of slab M20 |
| 19 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. (CSR 18.18) |
| 20 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth (CSR 11.4) |
| 21 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres. (CSR 6.8 c i) |
| 22 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material. (CSR 14.3) |
| 23 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm (CSR 14.15 a) |
| 24 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved exture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall ngle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per irections of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm. (CSR 13.86 i) |
| 25 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) (CSR 14.116) |
| 26 | Providing and Installation of Safety signage as per guideline for person with disability made ofretro reflective sheeting as per colour specified and writing matter will be of same material inwhite fixed / pasted over 4mm thick aluminum composite sheet, including cost of writing matterwith braille also firmly fixed on wall with nylon fastener, brass screw and washer complete asper specification and as desired by engineer in charge. (CSR 18.57) |
| 27 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973. Commercial with elm or gurjanfacing on both \ Sides with laminated core and lipped edges:-35mm thick (CSR 17.27 a (IV)) |
| 28 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)s CSR NO. - 17.23 I For shutter area up to 0.50 sqm |
| 29 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : CSR NO. - 17.49 (a) 300mm x 16mm |
| 30 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm) CSR NO. - 17.43 c |
| 31 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers (CSR 17.22 v) |
| 32 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with thehelp of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. CSR 18.39 |
| 33 | Providing and fixing of Back Panel of Reception comprising of framing of 50mm x 50mm Partal/ Sal wood. Panel on back side of reception. |
| 34 | Writing matter on front signage Using high intensity Microprismatic grade retro reflective Sheeting . |
| 35 | Providing & fixing of reception Table 5'-6\\" x 4'-6\\" and height 2'-3\\" with storage drawer space for legs etc |
| 36 | Providing & Fixing at site the pharmacy counter plan dimension as 5'-3\\" x 1'-10.5 and height 2'-6\\" with projected shelves storage drawers space for legs etc |
| 37 | Providing and fixing teak wood Gola (CSR 17.35 a) 50mmx12mm |
| 38 | Finishing of beading section 50mm x 12mm with Enamel paint two coat work |
| 39 | Providing and fixing Roller Blinds at the designated locations with fabric/ texture complete. |
| 40 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. CSR 17.973mm thick ACP Sheet |
| 41 | Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span. Up to 15.00 Mtr. Span. CSR 18.52 |
| 42 | Providing and Fixing Main Board Size 6x2 ft. Ayushman Arogya Kendra |
| 43 | 2 Pictures |
| 44 | Providing and Fixing Door Borders of size width 9 inch |
| 45 | Providing and Fixing Windows Borders and Circle Logos of Circle Diameter 4 x 4 ft. and Borders according to the size of window 9 inch width. |
| 46 | Providing & Fixing name plate of various sizes made of PVC Sheets |
| 47 | Providing & Fixing Letter of Mohalla Clinic |
| 48 | Providing & Fixing Top Khura (CSR 13.45) |
| 49 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3. (CSR 13.51) |
| 50 | Providing and fixing SS Braile indicators of size 170mm x 35mm to be fixed on handrails of the the approved design and make having Braile dots raised 0.5mm above base plate, to the installed at the specified locations as per the directions of the Engineer-in-Charge complete s per design/specifications and guidelines as per the entire satisfaction of the Engineer-in-Charge |
| 51 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) CSR 17.23 i |
| 52 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. CSR 8.26(a) |
| 53 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. CSR 8.26(b) |
| 54 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing CSR 13.13 |
| 55 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (CSR 13.55) |
| 56 | Marble stone flooring with 12-15mm thick marble stone (CSR 14.74 iv)b Udaipur Green Marble Tiles thickness |
| 57 | Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type. (CSR 10.9B(II)) |
| 58 | 12.5mm thick Cement Plaster (CSR 15.9) |
| 59 | 20mm thick cement plaster 1:4 in two coat work (CSR 15.20) |
| 60 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete. (CSR 16.6) |
| 61 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. CSR 16.17 |
| 62 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade CSR 16.10 |
| 63 | Finishing Walls with premium acrylic smooth exterior paint with silicone additives.(CSR 16.60) |
| 64 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. CSR 18.24 C |
| 65 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) CSR 18.38 |
| 66 | Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect CSR 18.26 |
| 67 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. CSR 18.27 |
| 68 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position CSR 18.4 |
| 69 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. CSR 18.25b |
| 70 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. CSR 16.17 |
| 71 | Painting one coat with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint. CSR 16.19 |
| 72 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. CSR 16.16 |
| 73 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. CSR 16.17 |
| 74 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. CSR 16.18 |
| 75 | Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. |
| 76 | Providing and applying Anti Termite Treatment using post constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 3 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications by drilling holes in the floor slab & along skirting 300 mm apart & 12 mm dia, drilling holes along all possible entry points such as junctions of floor and walls, door frames, sewage lines, entry points , etc. & injecting them with the chemical solution. CSR 14.132 |
| 77 | Cement concrete 1:4:8 with stone ballast 20mm gauge mixing by mechanical means using concretemixer volumetric type. CSR 10.11 (a) (ii) |
| 78 | Providing and laying 60 mm thick factory made cement oncrete interlocking Paving blocks of M35 grade anufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer- in Charge. CSR 14.138 |
| 79 | Providing and Fixing Mica on Both Side of Door |
| 80 | PHC WorkDismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex completein all respect. |
| 81 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 82 | Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / Chinaware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge. |
| 83 | Eurpoean/Indian/Orissa W.C., |
| 84 | PVC / China Ware Cistern |
| 85 | Wash Hand Basin / Urinal Pot |
| 86 | Stainless Steel Sink /Mosaic Sink |
| 87 | CP Bib Cock/Angle Cock/Stop Cock/Shower/Bottle Trap |
| 88 | Wall mixer / Sink Mixer / Basin Mixer /Concealed Stop Cock |
| 89 | Bathroom Assessories such as Soap Dish, Towel Rail, Towel Ring, Towel Bracket, Mirror, Toilet Paper Holder,Seat Cover, Jet Pressure and all other accessories. |
| 90 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregade 40 mm gauge and 100mm fine sand. |
| 91 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 92 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 93 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 94 | Chinaware Floor Mounted One Piece EWC rim less type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) size 69x36x74 cm with P trap or S trap and seat cover complete in all respect. |
| 95 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. |
| 96 | With C.P. Brass nut |
| 97 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
| 98 | Size 550 mm x 400 mm x 815 mm |
| 99 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 100 | Vitreous chinaware standard white pedestal for wash hand basin. |
| 101 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. |
| 102 | C.P. Brass extension piece, 25mm long to 50mm long |
| 103 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass fittings: |
| 104 | C.P. brass Bib cock with Wall flange |
| 105 | C.P.brass 15mm Angular stop cock with Wall flange |
| 106 | Providing and Fixing in position 15 mm I/D Bib Cock of approved make Complete in all respect. |
| 107 | CP brass Bib Cock Long Body Foam flow without flenge. |
| 108 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 109 | Providing and fixing in position towel rails /ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 110 | C.P. brass towel Rails size 15mm dia 610mm long |
| 111 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 112 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. |
| 113 | C.P. brass toilet paper holder |
| 114 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 115 | PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 116 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) |
| 117 | Size 600mmx450mm |
| 118 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball (For Tank) |
| 119 | 25mm i/d |
| 120 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 121 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
| 122 | 15mm i/d |
| 123 | 25mm i/d |
| 124 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 125 | CPVC SDR 11 Pipe & fitting 16mm o/d |
| 126 | Providing, fixing and jointing G.I Union Couplings (of approved make with the approval of EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. |
| 127 | 15 mm i/d G.I. Union |
| 128 | 25 mm i/d G.I. Union |
| 129 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 130 | Size 75 mm x 50 mm |
| 131 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 132 | Single Socket Type B |
| 133 | 110mm o/d SWR UPVC pipe lines laid complete |
| 134 | Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect. |
| 135 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 136 | For 110mm o/d pipes |
| 137 | Single Tee |
| 138 | Door Elbow 90 Degree (All side socketed) |
| 139 | P Trap/Floor Trap 110mm x 110mm |
| 140 | Single Y-Junction |
| 141 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 142 | Triple Layer Tanks |
| 143 | P/F CP brass jali for waste water pipe |
| 144 | Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. |
| 145 | 25mm i/d Gun Metal peet valve heavy pattern. |
| 146 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required |
| 147 | Through wall 11.43 cm thick |
| 148 | Through wall 22.86 cm thick |
| 149 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 150 | Water Cooler Full Steel Body 80/120 ltr Capacity without Stablizer |
| 151 | Supply & Erection of automatic voltage stabilizer for storage type water cooler, Wall mounted, Heavy duty, copper wounded with volt meter etc. along with 3 core cord of suitable length and 3 pin power shoe including erection, connection & testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. Make... V – Guard or its equivalent. |
| 152 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 153 | Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 3 Star Make:- O General/Diakin/Toshioba/carrier with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 154 | Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne3 Star Make:- O General/Diakin/Toshioba/carrier with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 155 | Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. |
| 156 | For 1.50 tonne split AC |
| 157 | For 2 tonne split AC |
| 158 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.uPVC Pipe 10 Kgf/cm225mm i/d |
| 159 | For 1.50 tonne split AC |
| 160 | For 2 tonne split AC |
| 161 | Foundation for PVC tank |
| 162 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 163 | G.I. tank nipple 25mm i/d |
| 164 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. |
| 165 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 166 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 167 | 450mm x 450mm inside with 455mm x 455mm cover and frame light duty double seal |
| 168 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 169 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 170 | 4.5 Kg. Capacity |
| 171 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 172 | 6 Kg. Capacity |
| 173 | Sluge/ Sand Cleaning of existing of Septic Tank complete in all respect. |
| 174 | Repair of existing manhole, septic tank ,i.c chamber |
| 175 | Construction of soakage pit 1.50 m Diametre & 3.07 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. (Rate as Per Analysis Attached) |
| 176 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
| 177 | Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm |
| 178 | Providing and fixing C.P. brass Urinal Spreader Ocular-Regular complete with fittings for urinals complete. |
| 179 | Providing and fixing in position 15mm C.P. Pillar cock foam flow of approved make (to the approval of Engineer-in-charge) |
| 180 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 181 | C.P.brass 15mm Concealed stop cock with flange. |
| 182 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.Inside size 75x120 cm and 120 cm deep |
| 183 | Providing Internal Electrical Installations: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 184 | Wiring fan point (With fan box) |
| 185 | Wiring light point |
| 186 | Wiring call-bell point |
| 187 | Wiring 6 Amp. wall socket point |
| 188 | Wiring 6 Amp. Plug control comprising wall socket point |
| 189 | Wiring 16/20 amp. power plug control point |
| 190 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 191 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 192 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 193 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 194 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 195 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 196 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 197 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 198 | Wiring Telephone socket point RJ11 (one module) |
| 199 | Wiring Networking socket point RJ45 (one module) |
| 200 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 201 | Overall size 1sq.mm (Un-sheathed) |
| 202 | Overall size 1.5sq.mm (Un-sheathed) |
| 203 | Overall size 2.5sq.mm (Un-sheathed) |
| 204 | Overall size 4sq.mm (Un-sheathed) |
| 205 | Overall size 10sq.mm (Un-sheathed) |
| 206 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): |
| 207 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 208 | Overall size 6sq.mm (2Core) Armoured (On-Surface) |
| 209 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 210 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 211 | Overall size 10sq.mm (4Core) Un-armoured (Loose) |
| 212 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 213 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 214 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 215 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 216 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 217 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 218 | PVC flexible pipe 25mm dia. |
| 219 | Copper Earthing |
| 220 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 221 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 222 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 223 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 224 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 225 | Ceiling Rose (Flush Piano type) |
| 226 | Bakelite Batten Holder (Large size) |
| 227 | MCB'S & MCB DISTRIBUTION BOARDS: |
| 228 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 229 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 230 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 231 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 232 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 233 | SP&N Double Door Distribution Board 8 way each |
| 234 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 235 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES: |
| 236 | Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:- |
| 237 | ICDP Changeover Switch 63amp., 415volts |
| 238 | SINGLE ARM BRACKETS FOR GI PIPE POLE: |
| 239 | Supply and erection of G.I. Pipe (A-Class) Single arm bracket of suitable length to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the existing surface/ wall with 2nos. MS flat clamp 25mm x 5mm, 30cm long and 4nos. fastner 10mm x 75mm long with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:- |
| 240 | Single Arm Bracket 1 metre Long G.I. Pipe 40mm Dia. |
| 241 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 242 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 243 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 244 | Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear ( IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021 |
| 245 | Supply and erection of 3 star rating Ceiling Fan 1200mm (48\\") with double ball bearing copper wound, full aluminium body, 3 no. of blades, white in colour including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. |
| 246 | Supply and erection of Venti Air Fan 250mm with aluminium louver shutter longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 247 | SITC of Wall Fan Size 400MM complete in all respect as approved and desired by the Engineer in-charges at site. |
| 248 | Supply ,erection,testing & commissioning of Pure Sine Wave Invertor 2000VA with 24month warranty with Ttolley for Two tall tubular batteries,connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. |
| 249 | Supply ,erection,testing & commissioning of 12volt- 200 AH Tall Tubular Battery with warranty 36 months including connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. |
| 250 | Supply,Installation and Comissioning of Frost Free Double Door Refrigerator capacity 235 / 245 Ltr complete in all respect. The Refrigerator shoud also conform to technical specifications attached herewith. Complete in all respect as approved and desired by the Engineer in-charges at site. |
| 251 | Providing -2Way Phone, Patient Token System,Local Area Networking:- |
| 252 | Supply Installation Testing and Commissioning of 16 port 10/100 PoE switch, 8*10/100 PoE port + 2 10/100 uplink, power budget 120W, IEEE 802.3af/at extended range 250 mtr complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 253 | Supply, installation, testing & commissioning of Category 6 UTP , 4 Pair This cable well exceeds the requirements of TIA/EIA-568-C.2 and IEC/ISO 11801. Construction: 4 twisted pairs separated by cross separator, 4 channel, polymer spine / full separator. Half shall not be accepted. Operates at bandwidth of 250 MHz, Conductor Solid Bare Electronic Grade Copper. Inner jacket should be PVC and outer should be PE, suitable for direct burial. Insulation: Polyethylene, Attenuation (< 36 db/100m), Pair – to – pair and PS NEXT, ELFEXT and PSELFEXT, Return Loss, ACR and PS ACR., Nominal Outer Diameter of Cable should be 9.70 mm and Conductor Diameter 0.56 mm (23 AWG), Cable should support operating Temperature from -20° to +60°C, Cable should come with printed sequential Length Counter on each meter, Cable support Conductor Resistance 93.5 OHMS/1000MTR@20 Degree, Mutual Capacitance of cable should be < 5.6nF/100m, Max Resistance Unbalance of cable should be 5% Max, Capacitance Unbalance of cable should max 330pF/100m, Cable support Delay Skew: < 45nS, Operating Voltage: 72V and NVP: 69%, Shall Supports Gigabit Ethernet (1000 base-T) standard and Operates at bandwidth of 250MHz complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 254 | Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. |
| 255 | S/I/T/C of intercom facility 1+1 Basic Plan Phone Ringer volume control switch Tone/ Pulse Switchable Redial Mute Flash Pause Intercom facility Call T, Holding the line / Music on Hold during call transfer Line use LED Indication, Secrecy during conversation between both phones, including connecting cables complete in all respect as approved and desired by the Engineer in-charges at site |
| 256 | SITC of Token Calling Display System having screen size 4 inches, Voice calling with Bell System, complete key pad Etc, calling display up to 60 meter cable (15 meter length included), serial communication design, Text Color Red Display Shape Rectangle, Power 5 W, Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital, Cash counter, Tehsil, Courts etc, Warranty 1 Year,220 VAC Operating Voltage character Capacity 3 Character, Power Consumption, Rectangular Metal body complete in all respects as desired by the Engineer in charge of work at site.. |
| 257 | Supply & installation of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks complete in all respects as desired by the Engineer in charge of work at site. |
| 258 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 259 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail