| 1 | Excavation in trenches in any type of soil, n. exc. 1.5m wide and n. exc. 1.5m deep and getting out complete. |
| 2 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundation mass concrete and filling complete. |
| 3 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc all as specified and directed. |
| 4 | M&L for providing reinforced cement concrete nominal Mix for type B1 (1:2:4) using 20mm aggregate for foundations, including rafts, footings, foundation beams,plinth beams, bases for column etcall as specified and directed. |
| 5 | Formwork to sides of pillars,posts, struts, piers, columns and stanchions etc all as specified and directed. |
| 6 | M&L for providing reinforced cement concrete nominal Mix for type B1 (1:2:4) using 20mm aggregate for Columns, pillars, piers, posts and struts etc all as specified and directed. |
| 7 | Formwork to sides of concrete in lintels, cantilevers, shelves etc all as specified and directed. |
| 8 | M&L for providing reinforced cement concrete nominal Mix for type B1 (1:2:4) using 20mm aggregate for beams, cantilevers, bressummers, lintels over 1.5m span etc all as specified and directed. |
| 9 | Formwork to chullah hoods, chajjas,troughs and similar items including edges etc all as specified and directed. |
| 10 | M&L for providing reinforced cement concrete nominal Mix for type B1 (1:2:4) using 20mm aggregate for chajja etc all as specified and directed. |
| 11 | M&L for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. |
| 12 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. |
| 13 | M&L for brick work with modular fly ash bricks straight or curved on plan exc 6m mean radius builet in cement mortar 1:6 complete all as specified and as directed. |
| 14 | M&L for 40mm damp proofing course in cement concrete 1:2:4 type B-0, horizantal or vertical surface including necessary formwork complete all as specified and as directed. |
| 15 | Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete complete all as specified and as directed. |
| 16 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil complete all as specified and as directed. |
| 17 | M&L for 15 mm thick rendering on brick work or concrete surface in two layer, in cement mortar 1:4 mixed with water proofing compound 200gm per 50Kg weghit of cement, surface finished even and smooth without using extra cement complete all as specified and as directed.Note : WPC will be measured and paid separtely under respective item. |
| 18 | Supply only integral water proofing compound complete. |
| 19 | M&L for 12 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 20 | M&L for 50mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base , surface finished even and fair without using extra cement complete all as specified and as directed. |
| 21 | M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection, laid in alternate ways, surface finished even and smooth using extra cement complete all as specified and as directed. |
| 22 | Moorum / Red Bajari filling in floor or pavings, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 23 | M&L for broken stone hard core of gauge n. exc. 63 mm deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rolled / rammed to a true surfaces complete all as specified and as directed. |
| 24 | M&L for 8 -10mm thick double charge vitrified ceramic tiles as in flooring, skirting or in any position and any shape, area of each tiles not exc 0.36 sqm set & jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 25 | M&L for reparing of newly plastered/concrete surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and as directed. |
| 26 | M&L for applying a birla wall care putty on wall as per manufacturer\\"s instruction complete all as specified and as directed. |
| 27 | M&L for applying two coats of oil bound distemper on wall including preparation of surfaces complete all as specified and as directed. |
| 28 | M&L for powder Coating aluminium, chowkats/frame made with aluminium section (heavy weight) of size 100x44x2mm thick, vertical styles & top rail of shutters with section 84x44x2mm thick and middle & bottom rail of shutters with section 112x44x2mm thick including 10mm thick tinted glass pane at top and 12mm thick both side pre-laminated board at bottom pane inserted in position including all necessary fixing arrangement, joining cleats, glazing clips, rubber packing, aluminium anodized beading, screws etc; floor hinges, aluminium tower bolt 200mm long-02 Nos., mortice lock 100mm size 4 lever, 100mm dia disc handles etc, fitted to shutters and frames fixed in opening with hold fasts of size 25x3mm flat 150mm long 6 nos in each frame including cutting holes in brick work and embedded in PCC (1:2:4) bed block of size 150x150x150mm each and match the existing surfaces complete all as specified and directed. |
| 29 | M&L for powder coated aluminium window or ventilator with shutters frame made with section (heavy weight) 44x44x2mm thick style rails of shutters with section 44x44x2mm thick including 10mm size aluminium butt hinges 02 Nos in each leaf, 10mm thick tinted glass pane as inserted including jointing cleats, glazing clips, rubber packing aluminium anodized beading, screws etc; aluminium tower bolts 100mm size each leaf, hooks and eyes ‘D’ fabricated aluminium handles 100mm size, frame fixed in openings with hold fast of 25x3mm flats, 150mm long 04 Nos in each frames including cutting holes in brick work and embedded in PCC (1:2:4) bed block size 150x150x150mm each and match the existing surfaces complete all as specified and directed. |
| 30 | S&F of aluminium grills, fixed with ‘F’ channel, DG-104 pattern, 5.50 mm thick and fixed to window complete all as specified and directed. |
| 31 | M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 32 | S&F for steel work as in tabular trusses/supproting pipes etc complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 complete all as specified and directed. |
| 33 | S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed. |
| 34 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 35 | S&F for 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 36 | Preparing new steel surfaces of any description exc 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and as directed. |
| 37 | S&F position suspended false ceiling system using T-grid suspended ceiling grid system . The size of grid shall be 600x600mm with GI frame work main runner 38x24x3600mm, cross T 25x24x600mm/25x24x1200mm and wall angle 24x24x40mm (thickness of the materail of 0.30mm) using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in the drop texture as per IS-2095, part-I 1996, fixed in the grid of T-grid suspended ceiling grid system duly susupended by 4mm dia GI bar hanged from the purlins of the roof with butter fly clips complete all as specified and as directed. |
| 38 | Supply, laying and jointing, 02 core 10 Sqmm LT under ground cable, 1100 V grade, XLPE insulated, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/path/drain/culverts or encored in GI pipe fixed & testing and commissioning complete all as specified and as directed. |
| 39 | M&L for double walled corrugated DWC HDPE pipe of outer dia 50mm and inner dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of cable protection complete all as specified and as directed. |
| 40 | M&L for point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 V grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.2mm thick, with modular cover plate with frame of adequate required modules for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for One light point point controlled by one, one way switch.Note :- (i) Modular plates and Steel sunken box included in quotated rates (ii) Making good the disturbed surface to match with existing surface |
| 41 | All as per item No 40.00 above but One fan point controlled by one, one way switch. |
| 42 | All as per item No 40.00 above but One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified and as directed. |
| 43 | All as per item No 40.00 above but on independent board. |
| 44 | All as per item No 40.00 above but with 2.5 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes. |
| 45 | S&F Modular switch,1 way 6A with \\"light / fan Marking\\", 1 module, 230 V complete all as specified and directed. |
| 46 | S&F Modular 16A, 1 Way Switch with Indicator, 1 module, 230 V complete all as specified and directed. |
| 47 | S&F in Modular socket 6A 3 Pin Round Socket with Shutter (ISI mark), 2 module, 230 V complete all as specified and directed. |
| 48 | S&F Modular socket 6A/16A 3 Pin Socket with Shutter (ISI Mark), 2 module, 230 V complete all as specified and directed. |
| 49 | S&F Modular fan regulator flush type 2 Module with 4 Step Regulator 100W (ISI mark), 230 V complete all as specified and directed. |
| 50 | Supply and fix ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish. |
| 51 | Supply, installation, testing and commissioning of maximum 36W backlit type 600x600mm recess mounting LED luminaire equipped with CRCA powder coating housing, high transmittance PF diffuser with symmetric light distribution , minimum system lumen output of 3600 lm, THD<20% CRI> 80. CCT6500K, high surge protection upto 3.5 kV, and operating temperature 0°C to +45°C, Driver safety requirement standards as per IS 15885-2 -13 complete all as specified and as directed. |
| 52 | Supply, installation, testing & commissioning of maximum 20W LED IP 20 batten with extruded aluminium housing in anodised finish, minimum system lumen 2200 Lumen in 20 W , THD<20%, CRI>80, CCT=6500K, high surge protection 4 kV and operating temperature 0°C to +45°C, Integrated LED driver offers comfortable soft light, high durability. Driver safety requirement standards as per IS 15885-2 -13.T. |
| 53 | S&F of distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240 V, 200 Amp rated bus bar with front openable cover suitable for SP & N 8 ways all as specified & directed. |
| 54 | S&F of MCB DP/SPN 32 Amps, 430 V, 50 Hz with 10 kA. |
| 55 | S&F of MCB SP 6-32 Amps, 230 V, 50 Hz with 10 kA. |
| 56 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thickness burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25x25mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion. |
| 57 | S&F of 35 Watt LED security light fitting luminaire, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with bracket of adequate size complte IP66 protection and impact resistance of IK08.E68 , including coneecting up with 2/3 core flexible coppper conductor cable, compete all as specified and as directed. |
| 58 | S&F brushless direct current (BLDC) ceiling fan 1200 mm sweep (ISI Marked), with super enamelled copper wire, white color, Class of insulation \\"B\\", 5 Satr rated, ISI marked, rated voltage 230Volt AC, 50 Hz , Rated power 26Watt (+-) 10%, Rated speed 350 RPM (+-) 10%, power factor 0.9 at 5th speed, Air delivery 210 Cum/min (CMM), operating temp 75 degree max, 3 nos aluminium blades and thickness 1.1 mm (after painting), Double ball bearing, speed control thorugh regualator, Low voltage starting i.e. 185 Volt minmum, Insulation resistance more than 2 mega ohm and lekage current 210 MICRO Amps Max includung connection rod as per existing length, writing MES Nos on ceiling fans complete all specified and as directed. |
| 59 | S&F of sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified. |
| 60 | Supply and install wall mounted Split Air Conditioner capacity 1.5 TR, Inverter type with indoor & outdoor, 5 star rated and EER 3.3 or more, R-32 refrogerant, Rotary compressor, Voltage range 220-240V, Power consumption 890W, 100% copper, cordless remote control, Auto Restart, Night glow buttons, Self Diagnosis, Hot & Cold, Conveniance features like 5 in 1 Convertible modes, Low Gas Detection, Cleaning Filter Indication, electric cable with Top, supply and discharge copper tube upto 3 RM with inbuilt air filtesr, Anti bacteria filter, Anti-Viral dust filter (PM 2.5 Filter), Auto air swing complete all as specified and as directed.Note :- The rate is included for following item-:(a) All other connected civil work like hole cutting & other misc work reqd for installation of split AC for proper functioning as directed by EIC. including making good disturbed surfaces as per existing.(b) S&F PVC pipe 15 mm dia transparent flexible heavy duty for water drainage pipe of upto 06 RM at site.(c) S&F copper pipe as per site requirement with insulation of complete pipe with PVC casing & caping of size 75x75mm reqd size for mechanical protection complete.(d) S&F Wall mounted stand for outdoor unit as suitable for fixing of AC. Please Enable Macros to View BoQ information |