| 1 | Dismantling of AC/fibre glass translucent corrugated or semi corrugated sheet including ridges, hips, valley etc of any description and thickness in roof coverings, complete all as specified and as directed. |
| 2 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixing with self taping screws, complete all as specified and as directed. |
| 3 | S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 4 | Dismantling wrought iron work or mild steel work of any description not otherwise provided for, complete all as specified and as directed. |
| 5 | M&L for prepraration of steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 6 | M&L for prepraration of old or previously untreated surfaces of steel over 10cm width or girth and applying one coats of synthitic enamel paint, complete all as specified and directed. |
| 7 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 (Gde E-165), complete all as specified and as directed. |
| 8 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness including cover fillets of any description, complete all as specified and as directed. |
| 9 | S&F fibrette tile made of 'Wood fibre cement composite' 1mm width wood fiber 15mm thick size 595mm x 595mm / 595 x 1195mm having excellent noise absorption of 1 NRC as per ISO:354, density 400 kg/m3, meets fire ratings as per BS 476 part 5, 6 and 7 class 1 and P, water resistant, and thermal insulated, installed on T24 grid system of 0.6mm thick main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm centre to centre and secondary cross 'T' of length 600mm web minimum 35mm inter locked. Wire support for main 'T' to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per fire resistant IS 15061-2002 for excellent results, complete all as specified and directed. |
| 10 | S&F in repair perforated particle/ tiles 16 mm thick for insulation and accoustic purposes, 60 x 60cm in size or as per site requirement, fixed with screws to timber frame work or with staples on snap grid, complete all as specified and directed. |
| 11 | Dismantling of brick tiles or terracing tiles single layer on roofs, complete all as specified and directed. |
| 12 | M&L of wire brushing neat cement slurry with 3 Kg of cement per Sqm at top and bottom of base coat and cleaning top surfaces, complete all as specified and directed. |
| 13 | M&L 40mm thick PCC(1:2:4) type B1, (using 20mm graded stone aggregate) finish even and smooth with using extra cement, complete all as specified and directed. |
| 14 | Material and labour for plastering 10 mm thick in cement mortar 1:4 mixed with WPC over cleaned concrete surfaces, complete all as specified and directed.Note : WPC will be measured and paid separately under respective item. |
| 15 | Supply only integral water proofing liquid, complete all as specified and directed. |
| 16 | M&L for APP Polymeric water proofing tratment with mineral finish to roof, at any height using membrane minimum 3mm thick and weighing not less than 3.6 kg per sqm, black finish reinforced with non-woven polyster matt weighting not less than 150 gms per sqm with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 ltr per sqm, torching ovarlaps with a propane or butane gas torch with a overlap of 100mm at the side on transverse direction and 150mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 kg per sqm below APP, complete all as specified and as directed. |
| 17 | M&L preparation of new surface of any description over 10 cm width or girth and applying one coat of aluminium paint, complete all as specified and directed. |
| 18 | Material and labour cement concrete tiles 25cmx25cmx22 mm thick set, jointed and pointed in neat cement slurry in floors/roofs with grey cement and pigments over and including 20 mm thick screed in cement mortar 1:6, complete all as specified and directed. |
| 19 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises . |
| 20 | M&L Non skid jointless cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment over and including 15mm thick screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 21 | All as per item No 20 above but in vertical surfaces as Dedo/Skirting over and including rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 rough finished surfaces to receive tiles. |
| 22 | Demolition of stone slabs and tiles of any description or thickness Laid, bedded and pointed in any mortar in floors, aprons etc, complete all as specified and directed. |
| 23 | M&L for machine cut kota stone slab 18 to 20 mm thick as in flooring / stair case landing, laid over & including 15mm thick cement screed base in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, complete all as specified and directed. |
| 24 | All as per item No 23 above but as in skirting /dado with 10 mm thick rendering in cement mortar 1:4. |
| 25 | Taking down cement plaster on brick wall/concrete surfaces etc including racking out joints hacking for key scrubing down with water etc of any thickness including dado of any description, complete all as specified and directed. |
| 26 | M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 furrowing the under layer scratching tool, applying cement slurry on the under layer @ 3Kg of cement per square meter, top layer 15mm cement plaster 1:1/2:2 (1 cement 1/2 coarse sand :2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings complete all as Haritage grith finish of colour, complete all as specified and directed.Note: Grooves shall be measured and paid separately under relevant item. |
| 27 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications, complete all as specified and directed. |
| 28 | S&F in repair rain water pipes single socketed, in any length with rubber ring joints, step clamps, including all fittings (Any type of \\"T\\"/tee, bend, Y, Branch piece single/double, couplers, reducers, vent coil, access door, junction single/double, equal/unequal, any type of traps including grating etc), 110 mm dia, fixed to walls/floor/trenches etc and height of buildings upto G+5, complete all as specified and directed. |
| 29 | M&L for 15 mm thick rendering in cement mortar 1: 6 on brick/concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 30 | M&L for preparation of new surface of wall and applying two coat of distemper oil emulsion over a coat primer above 2mm thick wall putty, on new surfaces including, complete all as specified and directed. |
| 31 | M&L for complete removal of old decorated plastered & unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts, trading oil and greasy pots applying two coat of distemper oil emulsion over a coat primer above 1mm thick plaster of paris putty, on old surfaces including new plastered face surfaces of wall, complete all as specified and directed. |
| 32 | M&L for preparation of old surfaces of porforated particle / tiles by brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts, trading oil and greasy spots and applying one coat of distemper oil emulsion paint on wall, complete all as specified and directed. |
| 33 | Material and labour for plastering 15 mm thick in cement mortar 1:4 mixed with WPC over cleaned concrete surfaces, complete all as specified and directed.Note : WPC will be measured and paid separately under respective item. |
| 34 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coats of alkali resistant priming paint including dark blue colour on pillar/RCC/brick facia, complete all as specified and directed |
| 35 | M&L for complete removal of old decorated plastered & unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts, trading oil and greasy pots applying two coat of cement base paint over a coat primer, complete all as specified and directed. |
| 36 | M&L 5mm thick cement plastering in cement mortar (1:3) as on ceiling surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 37 | M&L for preparation of new plastered surfaces and applying three coat of white wash on ceiling surfaces, complete all as specified and directed. |
| 38 | M&L for prepration of old surfaces of applying one coat of white wash on ceiling, complete all as specified and directed. |
| 39 | Taking down aluminium / copper point wiring with surface / concealed stove enamelled steel / PVC conduit or wooden batten (light, fan, socket or power) including sunk in cast iron / pressed steel terminal boxes such as switches, ceiling roses, lamp holders, sockets, regulators, call bell, light fitting any sketch etc and making good the disturbed surfaces of walls, floors etc, complete all as specified and directed. |
| 40 | Disconnecting and taking down old existing light fitting of any description from any position, complete all as specified and directed. |
| 41 | Disconnecting and taking down old existing sub main wiring of any description from any position, complete all as specified and directed. |
| 42 | M&L for Point wiring using proper colour coding complete with 1100 Volts grade 1.5 Sqmm, single core, PVC insulated, unsheathed cable with multistranded copper conductor with FRLS grade, confirming to IS-694 in and including PVC medium grade conduit not less than 25mm dia. ISI marked with all accessories concealed in wall / ceiling / floor / roof etc, including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets including 1.5 Sqmm PVC insulated, unsheathed, multistranded copper conductor, FRLS 1100 volts grade (green colour) as earth wire, connected to common earth dolly for:-One light point/ fan/Exhaust controlled by one switch. |
| 43 | All as per item No 42 above but One three pin switch socket 5 Amp outlet on same board. |
| 44 | All as per item No 42 above but One three pin switch socket 5 Amp outlet on independent board. |
| 45 | All as per item No. 42 above but with 4 sqmm PVC insulated FRLS, unseathed, cable confirming to IS-694, part-II with multistranded copper conductor cable in and including PVC conduit. |
| 46 | S&F Modular switch 1 way 6A, 1 module, complete all as specified and directed. |
| 47 | S&F Modular socket 6 Amp, 2/3 pin combined 2 module, complete all as specified and directed. |
| 48 | S&F Modular Switch 1 way 16 Amp 1 module, complete all as specified and directed. |
| 49 | S&F Modular Socket 6 Amp / 16 Amp, 2/3 pin, combined 2 module, complete all as specified and directed. |
| 50 | Supply & fixing LED luminarie 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed. |
| 51 | M&L for Sub main wiring with 2 X 2.5 Sqmm (Nominal Area) PVC insulated FRLSH unseathed, multi stranded 1100 volts grade copper conductor cable single core drawn through into and including non metalic PVC concealed conduit not less than 20 mm dia medium grade and its accessories including one run of 2.5 Sqmm PVC insulated copper conductor as earth wire including cutting chases and making good, complete all as specified and directed. Note :- Surface conduit shall be laid in ceiling portion only. |
| 52 | Supply, assembly and errection of GI sheet with TDF flage rectangular / square duct made out of 'L' shapped hollow profile, duly factory boxed including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size of 22 gauge, complete all as specified and directed. |
| 53 | Supply, installation, testing and commisioning of GI volume control duct damper complete with neoprene rubber gasket, nuts, bolts, screws linkage, flanges etc as per specification, complete all as specified and directed. Please Enable Macros to View BoQ information |